Manual 2100-702D
Page 2 of 29
CONTENTS
GENERAL................................................................... 3
Nomenclature ..................................................... 3
General Information ............................................. 3
Field-Supplied Tools Needed ................................ 3
Unpacking .......................................................... 3
Description ......................................................... 3
INSTALLATION OF FIELD-INSTALLED
ECONOMIZER........................................................... 4
Installation ......................................................... 4
Preparing Unit for Economizer Installation .......... 4
Outdoor Air Sensor Installation .......................... 8
Economizer Installation..................................... 8
Economizer Checkout ..................................... 10
Control Wiring Connection Diagrams..................... 10
START-UP/CHECKOUT PROCEDURES ............... 15
JADE™ Economizer Controller ............................ 15
Review/Customize System Setup...................... 15
Enthalpy Settings .............................................. 19
Economizer Sequence of Operation .....................20
Condition
–
Cool/Dry OA Conditions .................. 20
Condition
–
Warm/Humid OA Conditions ...........20
Economizer Operation for Single Stage .............22
Balanced Climate Mode – S, Y and Z Option
Economizer Sequence of Operation ..................23
Economizer Operation – Balanced Climate Mode
.. 24
FIGURES
Figure 1 Wall-Mount Unit Access Panels ............. 5
Figure 2 Condenser Exhaust Plate with Screen..... 5
Figure 3 Filter and Filter Brackets ...................... 6
Figure 4 Filter Bracket and Filter Bracket
Fill Plate Installation ............................ 7
Figure 5 Outdoor Air Sensor Installation.............. 8
Figure 6 Control Panel....................................... 8
Figure 7 Mixed Air Temp Sensor Installation ........ 9
Figure 8 Vent Option Door Installation............... 10
Figure 9 Programmable Thermostat Connections
for Air Conditioner with Economizer ..... 11
Figure 10 Programmable Thermostat Connections
for Heat Pump with Economizer .......... 12
Figure 11 Non-Programmable Thermostat
Connections for Air Conditioner with
Economizer ....................................... 13
Figure 12 Non-Programmable Thermostat
Connections for Heat Pump with
Economizer ....................................... 14
Figure 13 JADETM Economizer Controller ............. 15
Figure 14 100% Outside Airow Path................. 20
Figure 15 Mixed Airow Path ............................. 20
Figure 16 100% Closed Loop Airow Path .......... 19
Figure 17 CO2Sensor Default and Final Settings
Bard Part #8403-067 CO2Controller ... 25
Figure 18 Wiring Diagram – Enthalpy Sensor ....... 28
Figure 19 Wiring Diagram –
Temperature Only Sensor .................... 29
TABLES
Table 1 Economizer Application ........................ 3
Table 2 System Setup Menu Levels ................. 16
Table 3 Advanced Setup Menu Levels.............. 16
Table 4 Setpoints Menu Levels ....................... 17
Table 5 Checkout Menu Levels........................ 17
Table 6 Status Menu Levels............................ 18
Table 7 Alarm Examples................................. 18
Table 8 Unit Operation with S (Part Flow), Y
and Z (Full Flow) Economizer Options .. 23
GRAPHS
Graph 1 W/J18 Ventilation Delivery ................... 26
Graph 2 W/J24 Ventilation Delivery ................... 26
Graph 3 W/J30 Ventilation Delivery ................... 27
Graph 4 W/J36 Ventilation Delivery ................... 27
ECONOMIZER FEATURES
• One piece construction—easy to install.
• Exhaust air damper—built in with positive closed
position. Provides exhaust air capability to prevent
pressurization of tight buildings.
• JADE™ controller provides nearly limitless
customization on a solid, intuitive electronic
platform.
• Actuator Motor – 24 volt, power-open, spring-
return, direct-coupled with stall protection. Self-
centering shaft clamp and access cover facilitate
ease of replacement/maintenance.
• Proportioning-type control for maximum “free”
cooling economy and comfort with up to 100%
outside air.
• Enthalpy sensor to monitor outdoor air conditions.
• Minimum Ventilation Position available for required
ventilation of occupants or dilution of pollutants.
• Mixed air sensor to monitor outdoor and return air
to automatically modulate damper position.