Bodet NETSILON 7 Manuale utente

1
NETSILON
TIME SERVER
User Manual
On receipt, ensure that the product has not been damaged during transportation and report any concerns to the carrier.
BODET SA
1 rue du Général de Gaulle
49340 Trementines, France
Tel. support France: 02.41.71.72.99
Fax France: 02.41.71.72.01
Ref.: 608065 B
www.bodet-time.com
This document refers to the following products:
907,900 NETSILON 7 (100-240 VAC)
907,901 NETSILON 7 (18-36 VDC)
907,902 NETSILON 7 (100-240 VAC + 18-36 VDC)

2
CONTENTS
1. GENERAL POINTS 6
1.1 Using the guide 6
1.2 Introduction 6
1.3 Netsilon presentation 7
1.3.1. Front panel 7
1.3.2. Rear panel 7
1.4Specications 9
1.4.1. Precision 9
1.4.2. Connection 9
1.4.3. Mechanical characteristics 9
1.4.4. Electrical characteristics 9
1.4.5. Communications 9
1.4.6. Lists of network protocols supported 10
1.4.7. Synchronisation sources 10
2. INSTALLATION 11
2.1 Checking the package 11
2.2 Safety 11
2.2.1. Installing the equipment 11
2.2.2. Opening the equipment 11
2.2.3. Earth connection 11
2.3 Mechanical rack installation 12
2.4 Electrical installation 12
2.4.1. Power supply 12
2.4.2. Backup battery - CR2032 12
2.4.3. Ethernet 12
2.4.4. Alarm relay circuits 12
3. COMMISSIONING 13
3.1Factoryconguration 13

3
3.2 Choosing the LCD screen display language 14
3.3CongurationwithaDHCPserver 14
3.4CongurationwithoutaDHCPserver 15
4. WEB SERVER MENUS 16
4.1 Start-up 16
4.1.1. Presentation of the main menu 16
4.1.2. ConguringtheNetsilonfrontpanel 16
4.1.3. Changing the language 18
4.2Managingusers 19
4.2.1. Changing the password 19
4.2.2. Creating or modifying an account 19
4.2.3. Deleting an account 19
4.2.4. Restoring the default password 20
4.3Conguringthetimezone 21
4.3.1. Deningthelocaltimesystemanddate 21
4.3.2. Creating a time zone manually 21
4.3.3. Creating a time zone automatically 22
4.4Conguringthecomputernetwork 23
4.4.1. ETH0Ethernetportconguration 23
4.4.2. ETHERNETexpansioncard(ref.907920) 24
4.4.3. Managing network services 25
4.5Choosingsynchronisationsources 29
4.5.1. Status of sources 29
4.5.2. Priority of sources 29
4.5.3. Satellite receivers 30
4.6 NTP 31
4.6.1. NTPservice 31
4.6.2. NTPclient 32
4.6.3. NTPservers 33
4.6.4. NTPpeers 34

4
4.6.5. NTPkey 36
4.6.6. NTPAutokey 38
4.6.7. NTP-Anycast 39
4.7Timedistribution 40
4.7.1. AFNORexpansioncard(ref.907940) 40
4.7.2. PULSEexpansioncard(ref.907942) 41
4.7.3. CURRENTLOOPexpansioncard(ref.907944) 42
4.8Managementofnotications 43
4.8.1. SMTPconguration 43
4.8.2. SNMPtrapConguration 45
4.8.3. Congurationofalarms 46
4.9Systemsupervision 47
4.9.1. SNMPagent 47
4.10 Systemmonitoring 48
4.10.1.Home page 48
4.10.2.GPS statistics 49
4.10.3.NTPstatistics 50
4.10.4.NTPlog 51
4.10.5.Alarm history 51
4.11 Systemtools 52
4.11.1. Firmware updates 52
4.11.2.Loadingandsavingaconguration 52
4.11.3. Firmware version and online help 53
4.11.4.Factoryconguration 53
4.11.5.RestartingorswitchingoffNetsilon 53
4.11.6.Removinganexpansioncard 54
4.11.7.ExportingNTPlogs 54
5. CONFIGURATIONBYSSH 55
5.1Authenticationbypassword 55
5.2Authenticationbypublickey 56

5
6. CONFIGURATIONBYCONSOLE 58
7. CONTROLPANELMENUS 59
7.1Mainmenutree 59
7.1.1. System menu 60
7.1.2. Networkmenu 61
7.1.3. USB transfer menu 62
7.2Technicianmenu 63
8. SUPPORT 64
8.1 Status of LEDs on front panel 64
8.2Webbrowsernotopening 65
8.3Controlpanelinactive 65
8.4Datasynchronisation 65
8.5USBloading 66
8.6 BODET technical support 66
8.7Historyofupdatestothisguide 66
9. ANNEXES 67
9.1Annex1:synchronisation 67
9.1.1. Primary source / secondary source 67
9.1.2. Automatic selection 69
9.2Annex2:functions 70
9.3Annex3:rightsaccordingtoprole:administrator&user 71
9.4Annex4:savedsettings 72
9.5Annex5:listofcommandsets 73
9.6Annex6:secureleforSCPandSFTPtransfer 74

6
1. GENERAL POINTS
Thank you for choosing the BODET Netsilon time server. This product has been carefully designed to meet your
needs in accordance with ISO 9001 quality standards.
We recommend that you read this manual carefully before using the product for the first time.
Retain this manual throughout the lifespan of your product so that you can refer to it when necessary.
Failure to observe these instructions may cause irreversible damage and invalidate the warranty.
Non-contractual data. Bodet reserves the right to make changes to equipment, including functional, technical and
aesthetic changes or changes to colours, without notice.
This manual is subject to change without notice. To obtain the most recent version of this document, please refer to
our website: www.bodet-time.com.
Pleasenote:dependingonyourconfiguration(e.g.optioncards,NTPand/orGPSsynchronisation,etc.),
somefunctionspresentedinthisnoticemaynotbeavailableonyourNetsilontimeserver.
1.1 Using the guide
Different user profiles may be required to install or use this product.
According to the task to be performed and the proficiency level of the user, we recommend as follows:
>Little or no experience in this environment:
Read through this manual in its entirety before installing and configuring Netsilon.
>Good knowledge of this environment:
Read through this manual from Chapter 2. Installation
> If Netsilon is already operational:
In order to change a specific setting or gain a better understanding of its characteristics and functions, read
through this manual from Chapter 3.Commissioning. Use the search function, click on a PDF bookmark, or
use the table of contents.
> In the event of technical problems please refer to Chapter 7. Support.
Key to symbols:
: indicates advice, a recommendation or any other noteworthy information relating to use of Netsilon.
: indicates that special attention needs to be paid.
: indicates that misuse or failure to follow the instructions could result in a hazard. This information must be
taken into account when installing or using Netsilon.
1.2 Introduction
Netsilon is a time server designed to distribute a high-precision time signal.
Compact and modular, the Netsilon time server combines the precision of a master clock with the secure approach
of data networks:
> High-precision internal clock regulated by its own quartz TCXO.
> Order of priority for the different synchronisation references.
> Modular design allowing a wide variety of input/output signals (up to four option cards).
> Network security management: enable/disable encryption, authentication, and access protocols.
> Alarm information in the form of SNMP traps and e-mails.
Three versions are available, depending on the power supply:
> Netsilon 7 (100-240 VAC).
> Netsilon 7 (18-36 VDC).
> Netsilon 7 (100-240 VAC + 18-36 VDC).

7
1.3 Netsilon presentation
1.3.1. Front panel
The Netsilon front panel contains:
>a USB11port
> three status LEDs for power supply, synchronisation and alarms (Power, Sync. and Alarm) 2.
See Chapter 6.1 Status of LEDs on front panel
>a two-line LCD display 3,
> control keys 4for initial setup (full setup from the web server).
1.3.2. Rear panel
> NETSILON7(100-240VAC+18-36VDC)
1Earth.
2On/Off switch.
3Mains. IEC 320 AC power inlets.
418-36 VDC power supply terminal. 3.81mm terminal.
5Slots for option cards:
> NETWORK option card (RJ45), ref. 907920.
> AFNOR option card, ref. 907940.
> PULSE option card, ref. 907942.
> CURRENT LOOP option card, ref. 907944.
> NETWORK FIBER option card (2 SFP), ref. 907921.
The option cards are installed in our production factory. For subsequent installation, refer to the expansion card
installation guide.
6Common/Normally-Closed/Normally-Open relay contact output.
If contact Normally-Open: no alarms / If contact Normally-Closed: alarms.
1
34
2
1 2
3 6
5 5 5 5
7 8 9 10
SLOT A SLOT B SLOT C SLOT D
1 NetsilonsupportsUSBkeysformattedtoAT16/FAT32andNTFS

8
7Terminal for GPS antenna:
8Alarms input: interfaces with the dry contact of the client equipment.
9Serial port.
10 ETH0 network card.
> NETSILON7(100-240VAC)
> NETSILON7(18-36VDC)

9
1.4 Specications
1.4.1. Precision
Typicalvalues
Precision11x10-9
Stability2 1x10-7/day
Holdover35 ms (after 24 hours)
Alarm SNMP traps, email and relay contact
1average after 24 hours with GPS signal
2average after 2 weeks with GPS signal
3typical value, after 2-week GPS synchronisation at constant temperature
1.4.2. Connection
Input 1x GPS
Outputs 1x Ethernet, 4 slots for option cards
1.4.3. Mechanical characteristics
Construction Metal case - 1 U rack - 19”
Operating temperature 0°C to +50°C
Humidity level 0-90% without condensation
Protection class IP41
Weight 2.5kg
Dimensions 447 x 264 x 44.2mm
1.4.4. Electrical characteristics
Power supply
AC: 100-240 VAC 50/60 Hz
(1.4 A @ 115VAC, 0.85 A @ 230VAC)
DC: 18-36 VDC
MTBF 100,000 hours
1.4.5. Communications
Network port RJ45, 1000BASE-T (Gigabit)
Panel USB port (can be disabled) for saving and updating rmware
Keyboard (lockable) and LCD screen for network conguration

10
1.4.6. Lists of network protocols supported
PROTOCOLS
NTP V2, V3, V4 Compliant with RFC 1305 and 5905 protocols.
Supports Unicast, broadcast, Multicast, peering,
MD5 encryption and Autokey.
Client/’server mode: NTP requests per
second
> 2000
SNTP V3, V4 Compliant with RFC 1769, 2030, 4330 and 5905
MANAGEMENT
HTTP/HTTPS Browser-based conguration and supervision
SSH Conguration basique avec des jeux de
commandes par le port Ethernet
Console Conguration basique avec des jeux de
commandes par le port série
COMMUNICATIONS
IP Version 4
SERVICES
DHCP Version 4
SMTP Mail forwarding
SUPERVISION
SNMP Supports V1, V2C and V3 (traps + agents)
Relay contact / External input Sending and receipt of alarms
1.4.7. Synchronisation sources
Two synchronisation sources are available for Netsilon: the BODET GPS antenna or an NTP server present on the
computer network.
Questo manuale è adatto per i seguenti modelli
3
Indice
Altri manuali Bodet Altro