Bogen NYQUIST NQ-P0100 Manuale utente

Nyquist Matrix Mixer Pre-Amp
Configuration Guide
NQ-P0100
© 2021 Bogen Communications, Inc.
All rights reserved.
740-00022F
210419

ii
Contents
Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ii
List of Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iii
List of Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iv
Configuring the Nyquist Matrix Mixer Pre-Amp . . . . . . . . . . . . . . . . . . . . . . . 1
Using the Dashboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Standalone Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Updating Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Network Settings Tab Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Configuration Settings Tab Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Standalone Operation Configuration Settings . . . . . . . . . . . . . . . . . . . . . . . . . 11
Accessing Log Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Setting DSP Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Setting the Channel Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Signal LED, Clip LED, and VU Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Muting a Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Adjusting Volume Levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Selecting Input Type, Input Gain, and Phantom Power . . . . . . . . . . . . . . . . . . 22
Troubleshooting Gain Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Adjusting Compression Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Adjusting Ducking Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Adjusting the Graphic Equalizer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Setting High Pass/Low Pass Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Adjusting the Limiter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Adjusting Noise Gate Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Adjusting Parametric Equalizer Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Adjusting Router Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Signal Present . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

iii
List of Figures
Figure 1. Nyquist Appliance Login. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Figure 2. Matrix Mixer Pre-Amp Dashboard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Figure 3. Firmware Update Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Figure 4, Network Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Figure 5. Appliance Configuration Settings (Standalone disabled) . . . . . . . . . . . . . . . . . .9
Figure 6. Appliance Configuration Settings (Standalone enabled) . . . . . . . . . . . . . . . . .11
Figure 7, Logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Figure 8. DSP Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Figure 9. DSP Output Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Figure 10. Compressor Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Figure 11. Ducker Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Figure 12. Graphic EQ Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Figure 13. High/Low Pass Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Figure 14. Limiter Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
Figure 15. Noise Gate Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
Figure 16. Parametric Equalizer Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
Figure 17. Router Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
Figure 18. Settings Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
Figure 19. Signal Present Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42

iv
List of Tables
Table 1, Appliance Dashboard Fields. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Table 2, Appliance Dashboard Buttons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Table 3, Network Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Table 4, Configuration Settings (Standalone disabled) . . . . . . . . . . . . . . . . . . . . . . . . . 10
Table 5, Configuration Settings (Standalone enabled). . . . . . . . . . . . . . . . . . . . . . . . . . 12
Table 6, Logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Table 7, DSP Page . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Table 8, DSP Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Table 9, Compressor Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Table 10, Ducker Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Table 11, High Pass/Low Pass Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Table 12, Limiter Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Table 13, Noise Gate Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Table 14, Signal Present Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

1
Configuring the Nyquist Matrix Mixer
Pre-Amp
The Nyquist Matrix Mixer Pre-Amp (NQ-P0100) is a mixer preamplifier that allows micro-
phone, AES3 digital, and line-level source inputs to be integrated into a Nyquist system.
These input sources can then be routed to any endpoint or group of endpoints on the
network for paging or audio distribution.
You can let the Nyquist server automatically discover and configure the Matrix Mixer Pre-
Amp, or you can manually configure it through the Matrix Mixer Pre-Amp’s web-based
user interface (web UI).
A short press of the appliance’s Reset button reboots the device. If you press the Reset
button for 10 seconds, the appliance returns to the factory default configuration settings.
Returning to the default configuration settings does not change the appliance’s firmware.
The following sections describe settings and configurations that can be applied to this
device which are not controlled by the Nyquist server. For information about using
Nyquist’s automatic configuration process, refer to the Nyquist System Administrator
Guide.
To access the appliance’s UI:
1Access the appliance’s web UI by doing one of the following:
a) On your web browser, enter the IP address for the appliance as the URL.
b) From the Nyquist web UI navigation bar, select Stations, select Stations Status,
navigate to the device that you want to configure, and then select the Link icon.
Note: Do not use third-party Chrome browser extensions with the Nyquist user inter-
face.
Figure 1. Nyquist Appliance Login

2
2At the Nyquist Appliance Login page, enter username and password, and then select
Login.
The default username is admin; the default password is bogen.
The dashboard for the selected appliance appears.
Using the Dashboard
The dashboard displays the following fields:
Figure 2. Matrix Mixer Pre-Amp Dashboard
Table 1. Appliance Dashboard Fields
Device Type Identifies the model of this device.
Serial Number Identifies the serial number for the device.
MAC Address Specifies the Media Access Control (MAC) address,
which is a unique identifier assigned to network inter-
faces for communications on the physical network seg-
ment.
Firmware Version Provides the firmware version installed on the station.
Standalone Operation Enables or disables Standalone mode.

3
The following buttons are available at the top of all pages in the application.
Standalone Operation
This device can run in Standalone Operation mode, where it will not interact with a
Nyquist server (e.g., E7000 or C4000). This means the device will not:
• Fetch device configuration from Nyquist server
• Register with Nyquist server (via SIP)
• Store backup information to Nyquist server
• Allow access to Nyquist server-based NTP
Standalone Operation mode is ideal for scenarios that do not require the full functionality
provided by an integrated system, such as the Bogen C4000 or E7000 Series, but has the
Table 2. Appliance Dashboard Buttons
Dashboard Displays the dashboard.
Configuration Settings Accesses the Configuration Settings page, where you
can view and set various options. If Standalone Opera-
tion is not enabled, you can also receive configuration
settings from a Nyquist server.
Network Settings Accesses the Network Settings page where you can view
and set network settings, such as the static IP address.
Firmware Update Accesses the Firmware Update page where you can view
the current Nyquist version, update firmware to a new
version, restore the configuration to factory defaults,
and reboot the appliance.
Logs Accesses log files, which record either events or mes-
sages that occur when software runs and are used when
troubleshooting the appliance.
DSP Accesses the DSP page where you can view and set
parameters for Digital Signal Processing (DSP).
Help Accesses the appliance’s online help.
Manual Displays the Nyquist Matrix Mixer Pre-Amp Configura-
tion Manual.
Logout Logs out of the appliance’s dashboard.

4
ability to provide paging, multi-channel audio processing, and a SIP endpoint for a PBX/
VoIP phone system. It can be used to play music, audio, paging, and related functions.
Updating Firmware
When you select Firmware Update from the appliance’s web UI, the Firmware Update
page appears. From this page you can determine which Nyquist version the appliance is
using and if an update is required. You can also use this page to restore the configuration
to factory defaults and to reboot the appliance.
To use the Firmware Update page:
1On the appliance web UI’s main page, select Firmware Update to ensure you have
the latest firmware version.
2Select Upload Firmware to upload a firmware file from your computer to the appli-
ance.
If you select this option, a popup screen appears that allows you to select the file that
you want to upload. You can navigate to the file’s location. After you select the file,
Note: A Nyquist appliance connected to the Nyquist network receives a configuration
file from the Nyquist server that includes the latest firmware available from the server.
If the firmware is later than the one installed on the appliance, an automatic firmware
update occurs unless the Firmware parameter for the station is left blank. Refer to the
Nyquist System Administrator Guide for more information.
Figure 3. Firmware Update Page

5
select Upload. The page displays the uploaded firmware version and an Update
Firmware button appears. Select this button if you want to update the appliance’s
firmware to the uploaded version.
3If you want to return your appliance to its original configuration, select Restore Fac-
tory Settings.
4Select Reboot Appliance to restart your appliance.
Network Settings Tab Parameters
Network settings can be configured dynamically by the Nyquist server or manually by
using the appliance’s web UI.
To manually configure network settings:
1On the appliance web UI’s main page, select Network Settings.
2Select your desired network settings.
3Select Save.

6
Network settings are described in the following table:
Figure 4, Network Settings
Table 3, Network Settings
Static IP Identifies the IP address assigned to the appliance.
Netmask Identifies the subnetwork subdivision of an IP net-
work.
Gateway Identifies the address, or route, for the default gate-
way.
VLAN ID Identifies the Virtual Local Area Network (VLAN) for
this appliance. Values range from 0 to 4094.
VLAN Priority Identifies the priority of the network traffic on the
VLAN. Priority can range from 0 through 7.
Altri manuali per NYQUIST NQ-P0100
2
Indice
Altri manuali Bogen Amplificatore

Bogen
Bogen CT60B Manuale utente

Bogen
Bogen M-Class M300 Guida

Bogen
Bogen TBA-15 Manuale utente

Bogen
Bogen TPU-15A Guida

Bogen
Bogen TPU-15A Manuale utente

Bogen
Bogen Power Vector V250 Guida

Bogen
Bogen PM-3000 Manuale utente

Bogen
Bogen WV100 Manuale utente

Bogen
Bogen DMA-20 Istruzioni per l'installazione

Bogen
Bogen BPA-60 Manuale utente

Bogen
Bogen ProMatrix PM-3180 Manuale utente

Bogen
Bogen TPU-15A Manuale utente

Bogen
Bogen GA2 Guida

Bogen
Bogen Nyquist C4000 Series Manuale utente

Bogen
Bogen NYQUIST NQ-A2300 Guida rapida

Bogen
Bogen ORATOR Manuale utente

Bogen
Bogen PCMZPM Manuale utente

Bogen
Bogen TPU-35B Manuale utente

Bogen
Bogen CTM Manuale utente

Bogen
Bogen 600 ohm Manuale utente