BONAIRE 5000D Manuale utente

Owner’s Manual
BONAIRE®
Evaporative Air Conditioning
Installation Instructions
For help with installation or warranty issues call
1-800-939-2983 or www.bonaire-usa.com
For parts Visit our secure website www.bonairedurango.com
This product may qualify for rebates*
*Check with your local agency
Please keep this important manual in a safe place. It is the owner’s responsibility to
ensure that regular maintenance is carried out on this evaporative cooling product.
Failure to do so will void all guarantees beyond statutory and legal requirements.

INSTALLATION INSTRUCTIONS
2
Contents
INTRODUCTION…………………………………………………………………………….….3
UNIT LOCATION………………………………………………………………………………..6
UNIT INSTALLATION…………………………………………………………………………..7
UNIT INSTALLATION (SIDE DISCHARGE)………………………………………………..13
CHECK LIST…………………………………..………………………………………………..21
PROBLEM SOLVING……………………………………………………………………….…22
PARTS LIST…………………………………………………………………………………….23
MAINTENANCE………………………………………………………………………………...26
WARRANTY……………………………………………………………………………………..27
SERVICE………………………………………………………………………………………....29

INSTALLATION INSTRUCTIONS
3
1.0 Introduction
General Information
Thank you for purchasing a quality Bonaire Evaporative Cooler. We care about your safety and would
ask you to spend a few minutes reading these simple instructions before operating this product.
Safety!
Read carefully all of these instructions prior to operating the unit.
Read and Save these Instructions. Do not throw these Instructions away.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
Use this unit only in the manner intended by the manufacturer. Interference with and operation of
this cooler in any manner not prescribed by these instructions could cause a safety issue and WILL
void any warranty. If you have any questions, contact the manufacturer.
Before servicing or cleaning the unit, switch power off at the service panel and lock the service
disconnecting means to prevent power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag,
to the service panel.
Installation work and electrical wiring must be done by qualified person(s) in accordance with all
applicable codes and standards, including fire-rated construction.
Do not use cooler on uneven or unstable surfaces.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden
utilities.
Ducted fans must always be vented to the outdoors.
Use only with a 115V, 60Hz, 1 phase electrical supply.
Motor and pump have a grounded, molded plug and an automatic thermal overload which will stop
the motor operation if it overheats. The motor will restart again when it cools down.
The molded pump receptacle is for the grounded evaporative cooler pump only. Do not plug
anything else into this receptacle.
Do not alter or modify this cooler.
Do not allow children to operate or service this cooler.
WARNING: To reduce the risk of fire or electric shock, do not use this product with any solid state
speed control device.
Use only qualified electricians for replacement or servicing of switches, or electrical motors and
components in this cooler.
Always turn off power and unplug the fan motor and pump inside the cooler before installation or
maintenance and cleaning.
CAUTION: This unit has an unguarded impeller. Do not use in locations readily accessible to
people or animals.
Wiring shall be in accordance to the National Electrical Code, ANSI/NFPA 70

INSTALLATION INSTRUCTIONS
4
1.0 Introduction
Evaporative Cooling
The principal of your unit is to introduce fresh air, which is washed through the filter pads to
provide cool fresh air. The air is exhausted taking with it any heat loading on the home.
Exhaust
It is essential for successful operation of evaporative air-conditioning that there are sufficient
exhaust openings in the area to be ventilated. Open doors and windows will usually provide
this.
The minimum exhaust opening should be 10 ft² for the 5,000 cfm unit and 14 ft² for the 7,000
cfm unit.
5½ ft²
16 ft²
8 ft²
5½ ft²

INSTALLATION INSTRUCTIONS
5
1.0 Introduction
FAILURE TO COMPLY WITH THESE INSTRUCTIONS:
If this product is installed in a manner which is inconsistent with these installation instructions
or, if the product has been modified and or altered from its original form, we shall not be held
in any way liable to the purchaser of the product or any other person in connection with any
loss or damage that have may have been, or may in the future be, suffered or incurred as a
result of such incorrect installation or modification or alteration of the product.
Should you not follow these instructions the unit warranty may be void. The cost of warranty
would then be a cost to the customer or the installer / dealer.
Refer to the tick box Commissioning Checklist to ensure you have covered all points when
the installation is complete.
1.1 Important Notes
TEXT AND ILLUSTRATION COPYRIGHT CLIMATE TECHNOLOGIES Pty Ltd. 2016
All rights reserved. No part of this document may be reproduced or transmitted in any
form or by any means, electronic or mechanical, including photocopying, recording or
by any information storage and retrieval system, without prior permission in writing from
Climate Technologies.
Climate Technologies is constantly researching and developing improved product
features and therefore reserves the right to change the specifications without notice.
E. & O.E.
1.2 Before Commencing
Packaging – check there is no damage before removing packaging. Damaged units
should not be installed. Bonaire Customer Care Line should be contacted prior to
installation. Careless transportation by installer will not be covered by warranty.
Do not install damaged products. Contact the Bonaire Customer Care Line for
further advice.
Installed damaged products will not be covered by warranty.
Have you got all the system components?
Have you got the right unit?
Does the system design conform to the minimum specification of the sizing
specification and as such fall in line with sound engineering design practices?

INSTALLATION INSTRUCTIONS
6
2.0 Unit location
T LN
2.1 Unit Location Check List
EPA - A correctly installed unit will perform to specification on sound pressure radiated
noise. As an installer, you have a professional obligation to ensure that every practical
and reasonable effort is made to install this product to best practice guidelines and
ensure that any operational noise does not affect neighbours. Complying with EPA /
council by laws for noise abatement is the responsibility of the dealer / installer / owner.
NOTE: Do not mount the unit on a section of roof that slopes towards a
neighbour’s property.
Place the unit well away from sources of smoke, dust and objectionable fumes so that
only clean, fresh outside air will be drawn into the unit. Reference should be made to
relevant electric codes and state plumbing regulations.
Check the proposed location to ensure that building members are structurally capable
of supporting the operating weight of the air conditioner. You may need to consult the
roof truss manufacturer.
The unit must be installed in a position that gives safe access for service. It is the
responsibility of the dealer / installer to ensure safe access to the unit can be obtained
for servicing the product.
Where roof height, pitch or construction will cause OH&S concerns as previously
mentioned, service footing supports / platform and or harness anchorage must be
provided for safe service.
NOTE: The manufacturer and its service providers reserve the right to refuse
service unless safety and accessibility to the unit can be guaranteed.
The providing of any extra equipment required to give access to the unit for servicing or
warranty repairs is the responsibility of the owner.
The unit should face into the customer’s back yard, as low as possible on the roof,
with easy, unobstructed access. Keep the unit away from chimneys, flues and vents
that will pollute the filter pads and the fresh air being drawn into the house.

INSTALLATION INSTRUCTIONS
7
Unit Installation
3.1 Down Discharge installation
The evaporative cooler will be delivered with the fan motor assembly installed in “down
discharge” mode. See the image below.
The air will be directed downwards when installed in this configuration.
NOTE: This cooler is suitable for use with 17 ¾” and 19 ¾” duct sizes.
Down discharge configuration

INSTALLATION INSTRUCTIONS
8
Unit Installation
3.2 Electrical connections
NOTE: Use hand tools when refitting the screws, tightening the screws with power
tools can strip the screw holes.
3.2.1. Unscrew the thumb screws (transit screw) from the top of the grills.
3.2.2. Slide the removable grill upward and remove from the unit.

INSTALLATION INSTRUCTIONS
9
Unit Installation
3.2.3. To fit the electrical supply cable utilise the 7/8” hole in the panel. For electrical
connections, use a Listed, liquid tight, nonmetallic flexible conduit connector, of suitable
size for the panel conduit opening, and suitable for outdoor use. Secure the connector to
the panel with locking nut. See image below for hole location.
3.2.4. Remove the 3 screws from the control box to access the fan motor and pump
wiring harness to allow connection of the wiring.
3.2.5. Connect the wiring as shown in the diagram below.
WARNING:- Electrical connections should be performed by a qualified electrician so
that all electrical wiring conforms to local standards.
Control
box
Screw

INSTALLATION INSTRUCTIONS
10
Unit Installation
.
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali BONAIRE Condizionatore d'aria

BONAIRE
BONAIRE Durango 3100 Manuale utente

BONAIRE
BONAIRE 7000CFM Manuale utente

BONAIRE
BONAIRE PNE2002 Series Control Manuale di installazione e funzionamento

BONAIRE
BONAIRE Durango 350 Manuale utente

BONAIRE
BONAIRE Winter i AU Manuale utente

BONAIRE
BONAIRE B007RS Manuale utente

BONAIRE
BONAIRE Durango WEAC628 Manuale utente

BONAIRE
BONAIRE Optima L OHL 250D/ID Series Manuale utente

BONAIRE
BONAIRE B18 Manuale del proprietario

BONAIRE
BONAIRE VSS50 Manuale utente
























