1General 4
1.1 Introduction 4
1.2 Safety 5
1.3 Disposal 6
1.4 Components 7
1.5 Functional requirements 8
1.5.1 OSDP 10
1.5.2 Phg_crypt 10
1.5.3 Firmware overview 10
1.6 RFID technology 11
1.7 Transponder data 12
1.8 Reading distances 13
2Installation 15
2.1 General 15
2.1.1 Mechanical structure of the flush-mount version 15
2.1.2 Mechanical structure of the surface-mount version 15
2.2 Installing data and supply lines 16
2.3 Assembly preparation 17
2.4 Assembling the reader 18
2.5 Assembling the reader module 20
2.5.1 Configuring the reader (DIP switches) 20
2.5.2 Connecting and mounting the reader module 21
2.5.3 Unmounting the reader module 22
2.5.4 Resetting OSDP-key 22
3Care instructions 23
4Technical specifications 24
5More information 26

4en | General LECTUS select
2021-02 | 01 | F.01U.389.837 Installation manual Bosch Security Systems B.V.
1 General
1.1 Introduction
This installation manual is aimed at authorized service providers.
The installation manual contains instructions on the installation and configuration of the
Bosch Security Systems proximity reader LECTUS select.
1 2 3
456
789
C0E
Figure1.1: LECTUS select readers

LECTUS select General | en 5
Bosch Security Systems B.V. Installation manual 2021-02 | 01 | F.01U.389.837
1.2 Safety
–Read, observe and keep the instructions - the entire safety and operating instructions
must be read and correctly followed before the readers are operated.
–Take all warnings into account - follow all warnings on the devices and in the operating
instructions.
–Power sources - the readers should only be operated with the recommended power
sources. If you are unsure whether you can use a specific power supply, contact your
dealer.
!
Warning!
Risk of damage to the equipment!
Always switch off the power supply to the device before making changes to the installation.
Do not connect or disconnect any plugs, data cables or screws while the power supply is
switched on.
!
Warning!
Health and Safety!
Installation must be carried out in accordance with local fire, health and safety regulations. A
secured door must be installed as part of an escape route and must have:
- a fail-safe lock. the door must be released in the event of power loss. Ideally, a solenoid lock
should be used.
- an emergency switch with a glass cover for manual breaking the circuit, so that the fail-safe
lock can be de-energized immediately in an emergency.
!
Warning!
Risk of damage!
Protect the device against electrostatic discharge by observing the ESD instructions before
unpacking or touching the plug and the electronics.
i
Notice!
- The devices are equipped according to EN 60950, with protection class III.
- During the installation, make sure that the facility requirements placed by the corresponding
device safety standard are not influenced in an impermissible manner, compromising product
safety.
- Electromagnetic compatibility: The devices are designed for use in residential, business,
commercial and industrial areas.
i
Notice!
Installation and assembly of electrical components must be carried out by a qualified
electrician.
Caution!
The circuit board is at risk from electrostatic discharge. Appropriate precautionary measures
(grounding, etc.) must be observed.

6en | General LECTUS select
2021-02 | 01 | F.01U.389.837 Installation manual Bosch Security Systems B.V.
Danger!
- The device must be operated in a fully assembled state only.
- Before connecting the device to the power supply, make sure that the connected operating
voltage does not exceed the permitted values according to the technical specifications.
- Additional safety measures should be enforced whenever there is a risk that failure of
malfunction of the device might pose a risk to humans, animals or damage to the equipment,
this must be prevented with additional safety measures (limit switches, protective
equipment, etc.).
1.3 Disposal
Old electrical and electronic equipment
This product and/or battery must be disposed of separately from household
waste. Dispose such equipment according to local laws and regulations, to
allow their reuse and/or recycling. This will help in conserving resources, and
in protecting human health and the environment.

LECTUS select General | en 7
Bosch Security Systems B.V. Installation manual 2021-02 | 01 | F.01U.389.837
1.4 Components
x1 x2 x2
Quantity Component
1 Reader module
1 Locking bar
4 Screws
1 Quick installation guide
2 Safety instructions

8en | General LECTUS select
2021-02 | 01 | F.01U.389.837 Installation manual Bosch Security Systems B.V.
1.5 Functional requirements
The LECTUS select reader reads data from contactless RFID credentials and sends the data to
a higher-level control center. This is where the evaluation takes place as to whether a
credential is authorized or not. The result is sent back to the reader, which then provides a
visual and an acoustic signal. Communication between the reader and the control center takes
place via an encrypted RS485 bus.
The reader has a compact design and is available in two variants, with and without a keyboard
(each as a flush-mount version). The flush-mounted variant fits into any device box in flush-
mounted or hollow-wall design according to DIN, with a device screw distance of 60 mm.
The readers have tamper monitoring and tear-off detection (i.e. a sabotage message is
generated if the reader is completely torn from the wall). They are suitable for both indoor and
outdoor use.
Connection type: 8-pin screw / plug-in terminal
1 2 3
456
789
C0E
Figure1.2: LECTUS select readers without and with keypad

LECTUS select General | en 9
Bosch Security Systems B.V. Installation manual 2021-02 | 01 | F.01U.389.837
Surface-mount version
88 mm 41 mm 56 mm
80.4 mm
22 mm 1 mm
101 mm
93.4 mm
56 mm
3.5 mm
16.2 mm
21.2 mm
Accessories for surface-mount version: ARA-SELECT-SWA, ARA-SELECT-WWA
Flush-mount version
88 mm 19 mm 16 mm2 mm
101 mm
Wall bracket for flush mounting (part included)
The wall bracket is included in the reader delivery.
56 mm
7 mm
3.5 mm
50.5 mm
71.6 mm
14.5 mm
73 mm
26.2 mm25.7 mm
56 mm
60 mm

10 en | General LECTUS select
2021-02 | 01 | F.01U.389.837 Installation manual Bosch Security Systems B.V.
1.5.1 OSDP
The following readers support OSDP V2 protocol:
Commercial Type Number (CTN) Description
ARD-SELECT-BO Black, OSDP
ARD-SELECT-WO White, OSDP
ARD-SELECT-BOK Black, OSDP, Keypad
ARD-SELECT-WOK White, OSDP, Keypad
OSDP protocol is common within the Bosch Access Control Systems product portfolio.
1.5.2 Phg_crypt
The following readers support phg_crypt protocol:
Commercial Type Number (CTN) Description
ARD-SELECT-BP Black, phg_crypt
ARD-SELECT-WP White, phg_crypt
ARD-SELECT-BPK Black, phg_crypt, Keypad
ARD-SELECT-WPK White, phg_crypt, Keypad
These readers are not compatible with AMC2 controllers. Phg_crypt is a proprietary secure
protocol that can be used in third party installations such as MATRIX.
1.5.3 Firmware overview
LECTUS select Type Firmware
ARD-SELECT-BP, ARD-
SELECT-BPK, ARD-SELECT-
WP, ARD-SELECT-WPK
Phg_crypt 68350
ARD-SELECT-BO, ARD-
SELECT-BOK, ARD-SELECT-
WO, ARD-SELECT-WOK
OSDP 68435
Questo manuale è adatto per i seguenti modelli
9
Indice
Altri manuali Bosch Lettore di schede

Bosch
Bosch LECTUS enroll 5000 MD Manuale utente

Bosch
Bosch ARD-AYH12 Manuale utente

Bosch
Bosch ARD-FPBEW2-H3 Manuale utente

Bosch
Bosch PR113B Come usare

Bosch
Bosch LECTUS duo 3000 Manuale utente

Bosch
Bosch R90 Manuale utente

Bosch
Bosch ARD-AYK12 Manuale utente

Bosch
Bosch LECTUS duo 3000 Manuale utente

Bosch
Bosch ARD-FPBEW2-IC Manuale utente