Boulevard DVLL48NAT Guida rapida

INSTALLATION INSTRUCTIONS
AND OWNER’S MANUAL
DIRECT VENT
ZERO CLEARANCE GAS
FIREPLACE HEATER
MODEL SERIES:
MULTIFUNCTION
REMOTE (MF)
DVLL48SP90(N,P)-1
UL FILE NO. MH30033
This appliance may be installed in an
aftermarket, permanently located,
manufactured home (USA only) or mobile
home, where not prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate.
This appliance is not convertible for use with
other gases, unless a certied kit is used.
WARNING
If not installed, operated and maintained
in accordance with the manufacturer’s
instructions, this product could expose you
to substances in fuel or from fuel combustion
which can cause death or serious illness.
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly
could result in serious injury, death or
property damage.
— Do not store or use gasoline or other
ammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do
not use any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier
from a neighbor’s phone. Follow the
gas supplier’s instructions.
• If you cannot reach your gas supplier,
call the re department.
— Installation and service must be
performed by a qualied installer,
service agency or the gas supplier.
HOT GLASS
DO NOT TOUCH
NEVER
WILL
CAUSE BURNS.
GLASS
UNTIL COOLED.
ALLOW CHILDREN
TO TOUCH GLASS.
WARNING
A barrier designed to reduce the risk of burns from the
hot viewing glass is provided with this appliance and shall
be installed for the protection of children and other at-risk
individuals.
NOTICE: Barrier required, may be sold separately.
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
GAS-FIRED

37754-0-0717Page 2
TABLE OF CONTENTS
Attention Installer...........................................................................................................................3
Introduction....................................................................................................................................4
Before You Start....................................................................................................................... 5 - 6
Carton Contents & Hardware Pack................................................................................................7
Specications.................................................................................................................................8
Accessories ...................................................................................................................................9
Orientation Of Fireplace...............................................................................................................10
Fireplace Dimensions (Indoor Application) ..................................................................................11
Clearances (Indoor Application)...................................................................................................12
Fireplace Dimensions (W/DFED489SS)......................................................................................13
Clearances (W/DFED489SS) ......................................................................................................14
Locating Fireplace .......................................................................................................................15
Vent Termination Clearances............................................................................................... 16 - 17
Gas Supply .......................................................................................................................... 18 - 19
Safety Information For Users of LP Gas......................................................................................20
Electrical Connections ......................................................................................................... 21 - 22
Component Wiring Diagram ........................................................................................................23
Installation............................................................................................................................ 24 - 29
Vent System Identication ...........................................................................................................30
Venting Fireplace ................................................................................................................. 31 - 32
Venting (Horizontal) .....................................................................................................................33
Venting - Horizontal Termination..................................................................................................34
Top Vent - Vertical Termination ....................................................................................................35
Vertical Termination ............................................................................................................. 36 - 37
Dvvk-5F Flex Vent Instructions ............................................................................................ 38 - 39
Framing And Finishing......................................................................................................... 40 - 41
Liner Installation...........................................................................................................................42
Glass Placement..........................................................................................................................43
Multifunction Remote Operating Instructions....................................................................... 44 - 51
Control System Troubleshooting.......................................................................................... 52 - 53
Lighting Instructions.....................................................................................................................54
Parts List......................................................................................................................................56
Parts View....................................................................................................................................57
Maintenance And Service.................................................................................................... 58 - 60
Important Safety Information .......................................................................................................61
Fireplace Service History.............................................................................................................62
Requirements For Massuchusetts...............................................................................................63
Master Parts Distributor List ........................................................................................................64
How To Order Repair Parts..........................................................................................................64
Warranty ......................................................................................................................................65
SECTION PAGE

37754-0-0717 Page 3
ATTENTION INSTALLER:
Fireplace Installation Checklist
Use this checklist in conjunction with the instructions in this manual.
Customer: _____________________________________
Lot/Address: ___________________________________
_______________________________________________
Model: ________________________________________
Serial # ________________________________________
Date Installed: __________________________________
Fireplace Location: ______________________________
Installer: _______________________________________
Dealer Phone #: _________________________________
_______________________________________________
Empire recommends the following:
• Keep this checklist visible on the replace until the installation is complete.
• Photograph the installation and copy this completed checklist for your le.
Comments: Further description of the issues, who is responsible (Installer/Builder/Other) and corrective action needed:
___________________________________________________________________________________________________________
Comments communicated to party responsible _____________________by_____________________ on ______________________
FIREPLACE INSTALLATION COMMENTS
Veried clearances to combustibles (page 14)..................................................................... o____________________
Fireplace is leveled and secured.......................................................................................... o____________________
VENTING
Venting conguration complies to vent diagrams (page 29)................................................. o____________________
Venting installed, locked, secured in place with correct clearance....................................... o____________________
Firestops installed................................................................................................................. o____________________
Exterior wall/roof ashing installed and sealed..................................................................... o____________________
Terminations installed and sealed (pages 34-36) ................................................................. o____________________
Light unit and test venting before enclosing the replace .................................................... o____________________
ELECTRICAL (Pages 19-21)
Unswitched power (110-120 VAC) provided to the replace ................................................ o____________________
GAS (Pages 17-18)
Proper appliance for fuel type............................................................................................... o____________________
Was a conversion performed?.............................................................................................. oYes oNo
Leak check performed and inlet pressure veried................................................................ o____________________
FINISHING (Pages 23-24)
Non-combustible board installed .......................................................................................... o____________________
Veried all clearances meet installation manual requirements............................................. o____________________
Mantels and wall projections meet requirements ................................................................. o____________________
Finishing complies with clearance requirements.................................................................. o____________________
Barrier for glass front properly installed................................................................................ o____________________
FIREPLACE SETUP
All packaging and protective materials removed (inside & outside of replace) .................. o____________________
Media installed correctly....................................................................................................... o____________________
Firebox glass doors cleaned, installed, and secured............................................................ o____________________
Accessories installed properly.............................................................................................. o____________________
Started Fireplace and veried no gas leaks exist................................................................. o____________________
Manual envelope and all of its contents removed from inside/outside the
replace and given to party responsible for use and operation............................................ o____________________

37754-0-0717Page 4
Instructions to Installer
1. Leave instruction manual with owner.
2. Have owner complete the Product Registration Card
supplied with the replace or register online.
3. Show owner how to start and operate the replace.
This direct-vent gas replace heater is designed to operate with
all combustion air being siphoned from the outside of the building
and all exhaust gases expelled to the outside of the building. The
information contained in this manual pertains to all models and
gas control systems unless otherwise noted.
Appliance Certication
WARNING
This replace is not for use with solid fuels. Burning solid
fuels could cause personal injury or property damage.
This replace is design certied in accordance with American
National Standard/CSA Standard ANSI Z21.88/CSA 2.33 and by
Underwriters Laboratories as a Direct-Vent Gas Fireplace Heater
and shall be installed according to these instructions.
Consult your local building code agency, prior to installation,
to ensure compliance with local codes-including permits and
inspections.
The replace, when installed, must be electrically grounded in
accordance with local codes or, in absence of local codes, with
the National Electric Code ANSI/NFPA 70 or Canadian Electric
code, CSA C22.1, if an external electrical source is utilized.
These models may be installed in a bedroom or bed-sitting room
in the U.S.A. and Canada.
Qualied Installing Agency
Installation and replacement of gas piping, gas utilization
equipment or accessories and repair and servicing of equipment
shall be performed only by a qualied agency. The term “qualied
agency” means any individual, rm, corporation or company
which either in person or through a representative is engaged
in and is responsible for (a) the installation or replacement of
gas piping or (b) the connection, installation, repair or servicing
of equipment, who is experienced in such work, familiar with all
precautions required and has complied with all the requirements
of the authority having jurisdiction.
Commonwealth of Massachusetts: The installation must be
made by a licensed plumber or gas tter in the Commonwealth
of Massachusetts.
WARNING
ANY CHANGE TO THIS FIREPLACE OR ITS CONTROLS
CAN BE DANGEROUS.
Improper installation or use of the replace can cause serious
injury or death from re, burns, explosions, or carbon monoxide
poisoning.
The installation must conform with local codes or, in the absence
of local codes, with the National Fuel Gas Code ANSI Z223.1/
NFPA 54* Natural Gas and Propane Installation Code, or CSA
B149.1 in Canada. *Available from the American National
Standards Institute, Inc. 11 West 42nd St., New York, N.Y. 10036.
Any alteration of the original design, installation other than
as shown in these instructions or use with a type of gas not
shown on the rating plate is the responsibility of the person
and company making the change.
NOTICE: All correspondence should refer to complete Model
Number, Serial Number and type of gas.
High Altitude
When installing this replace at an elevation above 2000 feet
(in the United States) it may be necessary to decrease the input
rating by replacing the existing burner orice with a smaller size.
Generally, you should be reduce input by 4 percent for each 1000
feet above sea level. However, if the heating value of the gas has
been reduced, this may not apply. Check with Empire Comfort
Systems for proper orice size identication.
Canadian High Altitude
Altitude: 0-4500 feet (0-1370 m)
When installing this replace at an elevation above 4500 feet (in
Canada), check with Empire Comfort Systems for assistance in
determining the proper orice for location.
INTRODUCTION

37754-0-0717 Page 5
BEFORE YOU START
UNPACKING THE FIREPLACE
1. Cut binding straps and shrink wrap.
2. Remove top board and corner posts.
3. Lift replace from the pallet and place it near installation site.
4. Remove non-combustible boards from pallet and set aside.
5. Verify that the replace and components have not been
damaged during shipping.
6. Using list on page 56 verify that you have all components
that shipped with replace.
TELEVISION CONSIDERATIONS
Installing a television above a replace has become increasingly
popular; however, the area above any replace gets hot and most
TV manufacturers recommend against placing their products
near a heat source.
If you install a television above this replace, Empire Comfort
Systems accepts no responsibility for damage or injuries. Follow
the television manufacturer’s installation instructions, including
any recommendations regarding proximity to heat sources.
If you have a TV above your replace, turn off the replace and
let it cool completely before servicing or touching any buttons
on the TV.
SAMPLE WARNINGS AND DEFINITIONS:
DANGER
Indicates a hazardous situation which, if not avoided, will
result in death or serious injury.
WARNING
Indicates a hazardous situation which, if not avoided, could
result in death or serious injury.
CAUTION
Indicates a hazardous situation which, if not avoided, could
result in minor or moderate injury.
NOTICE: Addresses practices not related to personal injury.
____________________________________________________
This direct-vent gas replace and its components are tested
and safe when installed in accordance with this installation
manual. Report to your dealer any parts damaged in shipment,
specically check glass for chips or cracks. Do not install
replace with damaged, incomplete, or substitute parts.
Read all instructions before starting installation and follow
them carefully to ensure safe operation. Failure to follow the
instructions will void the warranty and may cause a re hazard.
The warranty will be voided by, and the warrantor disclaims
any responsibility for the following actions:
•Installation by anyone other than the dealer or his agent.
• Installation of any damaged replace or component.
• Modication of the replace or Direct-Vent system.
•Installation other than as instructed by Empire Comfort
Systems.
•Improper positioning of logs, glass door, or accessories.
•Installation and/or use of any component part not
manufactured or approved by Empire Comfort Systems.
All correspondence should refer to complete Model Number, Serial
Number and type of gas. Fill out the Homeowner Reference Section.
See page 3.

37754-0-0717Page 6
BEFORE YOU START (CONT’D)
PREPARATION
This replace and its components are safe when installed in
accordance with this manual.
INSTALLATION CONSIDERATIONS
•Gas supply piping – right side entrance - See page 10.
•Electrical supply and connections 120V, 60Hz, 1 Amp,
right side entrance - See page 10.
• Allowable replace mounting surfaces:
1. A hard, at, combustible or non-combustible surface
2. A raised platform of combustible or non-combustible
material.
3. The four corners of the replace on non-combustible
material – such as cinder blocks (where allowed by local
codes) – so that contact is made on all four perimeter
edges on the bottom of the replace.
• If the replace is installed directly on carpeting, tile or other
combustible material other than wood ooring, install a metal
or wood panel underneath extending the full width and depth
of the replace.
• This replace is designed to be installed in a zero-clearance
enclosure. Combustible material can come in contact with
the side standoff spacers, and the replace can be secured
to combustible framing with the framing brackets provided.
PLANNING THE INSTALLATION
Determine where the replace will be located and what
accessories will be installed.
Your location must allow for:
• Venting – either vertical or horizontal.
• Choose a vent conguration. See pages 34-36 and make
sure the required access through attics and walls is not
blocked by other utilities such as water lines, sewer vents,
gas lines, etc. If access is blocked, move the utilities or
relocate the replace.
• Gas supply piping (right side entrance) - See pipe size and
specs on page 17.
• Electrical supply requirements (120V, 60Hz, 1 Amp) - right
side entrance - See page 10.
• Proper framing required for replace installation.
See page 22.
• Finishing the replace – drywall thickness, tile or stone
thickness, and desired decorative accessories can affect
how you frame the openings and how you attach the nailing
anges to set the proper depth. See pages 23 - 24 for
nishing details, before you begin.
ACCESSORIES
Accessories for this appliance may be installed prior to or after
tting the replace into the framed opening.

37754-0-0717 Page 7
CARTON CONTENTS & HARDWARE PACK
Items not shown to scale.
INDEX
NUMBER DESCRIPTION QUANTITY
SUPPLIED
1Door Removal Tool (attached to
replace) 1
2 Product Registration Card 1
3 AA Battery 4
4 AAA Battery 3
5 Cover Plate, Battery Box 1
6 Remote 1
7 Junction Box Cover 1
8 Duplex Receptacle 1
9 Flue Restrictor 1
10 Battery Box 1
*11 Wire Harness 1
A #10 x 1/2 Screw 39
**B #8 x 1 Self-Drilling Screw 36
C Nailing Flange 8
** For use in mounting non-combustible board to standoffs.
* Not shown
See Parts Lists on page 50 for ordering replacement parts. Do
not order batteries, bolts, screws, washers or nuts. They can be
purchased at your local hardware store.
1
2
3
5
6
4
7
9
8
OR
10
1
2
3
5
6
4
7
9
8
OR
10
#8 X 1” PHILLIPS SELF-DRILLING SCREW
A
B
C

37754-0-0717Page 8
SPECIFICATIONS
MODEL DVLL48NAT DVLL48LP
Input BTU/Hr Maximum 37,000 34,000
Input BTU/Hr Minimum 25,000 27,000
KWH (Maximum) 11.13 9.95
KWH (Minimum) 7.32 7.90
Orice #31 #50
Air Shutter Opening Front (inches) 1/16 Full Open
Height without standoff (inches) 34-1/2 34-1/2
Width (inches) 61-1/4 61-1/4
Depth (inches 20-1/2 20-1/2
Gas Inlet Shutoff Valve (pipe) 1/2 NPT 1/2 NPT
NOTICE: Air shutter settings are factory minimum settings. Some venting congurations may require minor air shutter adjustments for
optimum performance.
GAS SUPPLY PRESSURES (Inches water column)
Gas Type Maximum Minimum Manifold
NAT 14 4.5 3.5
LP 14 11 10

37754-0-0717 Page 9
ACCESSORIES
ACCESSORIES
Description Model Color Used On
Conversion Kit - LP to NG 36435 NA DVLL48SP
Conversion Kit - NG to LP 36434 NA DVLL48SP
Trim Kit (Beveled) DF48BL Black DVLL48SP
Trim Kit (Beveled) DF48HP Pewter DVLL48SP
Window Frame (Beveled 2 inch) DF482NB Nickel DVLL48SP
Decorative Front DFF48FPD Pewter DVLL48SP
Liner Ledge Stone DVP48SLG Stone DVLL48SP
Liner Black Porcelain DVP48SLKR Black DVLL48SP
Log and Rock Set LS60THF NA DVLL48SP
SS Front (Exterior Install) DFED489SS NA DVLL48SP
Crushed Glass Media (Black) * DG1BKP Black DVLL48SP
Crushed Glass Media (Blue) * DG1BUC Blue DVLL48SP
Crushed Glass Media (Clear) * DG1CLF Clear DVLL48SP
* Six square feet required. These model numbers contain approximately one square foot each.

37754-0-0717Page 10
ORIENTATION OF FIREPLACE
NOTICE: When you are looking at the front side of the replace,
the pilot will be to your right on the opposite side of the burner.
The gas line access and junction box will also be on your right.
The DFED489SS Outdoor Kit may be installed only on the
back side of the replace.
The front glass frame may be removed for service. The rear glass
frame is xed in place.
Figure 1
PILOT (TOWARDS RIGHT,
BEHIND THE BURNER)
FRONT BACK (OUTDOOR KIT
INSTALLATION SIDE)
RIGHT-SIDE VIEW
VENT BIASED
TOWARDS BACK
JUNCTION BOX &
GAS-LINE BIASED
TOWARDS FRONT
BACK (OUTDOOR KIT
INSTALLATION SIDE)
FRONT
BACK (OUTDOOR KIT
INSTALLATION SIDE)
VENT BIASED
TOWARDS BACK
JUNCTION BOX &
GAS-LINE BIASED
TOWARDS FRONT
FRONT
PILOT (TOWARDS RIGHT,
BEHIND THE BURNER)
RIGHT-SIDE VIEW
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Boulevard Camino da interno

Boulevard
Boulevard LS41TDF-1 Guida rapida

Boulevard
Boulevard VFSL30FP7010(N Guida rapida

Boulevard
Boulevard DVLL48SP90N-1 Guida rapida

Boulevard
Boulevard VFLL60SP90LP-1 Manuale utente

Boulevard
Boulevard VFLB60SP90-1 Manuale utente

Boulevard
Boulevard VFLL72FP90LN-1 Guida rapida

Boulevard
Boulevard LS60THF-1 DVLL60BP90N-1 Guida rapida

Boulevard
Boulevard DVLL48BP92N-1 Guida rapida

Boulevard
Boulevard VFLL60FP90LN-1 Guida rapida

Boulevard
Boulevard VFLL60SP90LN-1 Manuale utente