Brivis B061526 Manuale utente

Brivis
Ducted Reverse
Wired Programmable Controller
OWNERS MANUAL
Cycle Inverter
PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE
INSTALLING & USING THIS PRODUCT
Bonus offer
when you
register your
product online
brivis.com.au
Part Number: B061526
November 2013
ABN 64 096 079 088
AU24752
For all your Sales and Service enquiries call us on 1300 BRIVIS (1300 274 847)
www.brivis.com.au
Brivis Australia
61 Malcolm Rd
Braeside Victoria 3195
Australia
1300 BRIVIS (1300 274 847)
Fax: +61 (03) 9264 9400
www.brivis.com.au
email: [email protected]
Brivis New Zealand
Distributor: Warm Air Ltd
69 Marsden Street
Lower Hutt 5010 New Zealand
PO Box 38523
Wellington Mail Centre
Wellington 5043 New Zealand
0800 WARMAIR (0800 9276 247)
Ph: +64 (04) 920 1670
Fax: +64(04) 920 1681
www.warmair.co.nz
email: [email protected]
Brivis South Africa
Distributor: Lorenz and Associates
Northlands Deco Park
Cnr Witkoppen and Newmarket Roads
North Riding, Johannesburg South Africa 2194
0861 BRIVIS (0861 274 847)
Ph: +27 (011) 704 6112
Fax: +27 (011) 704 0022
www.brivis.co.za
email: [email protected]
© 2013 Brivis Climate Systems Pty. Ltd.
All rights reserved. No part of these documents may be used in any way or form without prior written consent from Brivis Climate Systems Pty Ltd.
Brivis Climate Systems Pty. Ltd.
Specifications subject to change without notice. © 2013 Brivis Climate Systems Pty. Ltd.

2. INSTALLATION ACCESSORIES............................................................... 2
3. INSTALLATION METHOD........................................................................ 4
4. WIRED PROGRAMMABLE CONTROL WIRING DIAGRAM................... 7
5. SPECIFICATIONS..................................................................................... 8
6. LCD DISPLAY LAYOUT ........................................................................... 9
7. BUTTON DESCRIPTION ..........................................................................10
8. PREPARATORY OPERATION..................................................................12
9. OPERATION............................................................................................13
10. TIMER FUNCTIONS................................................................................18
11. WEEKLY TIMER (TIME CLOCK OPERATION)........................................ 21
12. FAULT CODE DEFINITION.................................................................... 27
that should be brought to your attention during operation.
● In order to ensure correct service of the wired control,
B026004, please read this manual carefully before using
● For convenience and for future reference, please keep this
manual in a safe place after reading it.
● This manual provides detailed descriptions of precautions
the unit.
CONTENTS
1. SAFETY PRECAUTIONS........................................................................... 1
● Due to our policy of continuous improvement, product
details and specications are subject to change without
notice.
● This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental
capabilities, or lack of knowledge, unless they have been
given supervision or instruction concerning the use of the
appliance by a person responsible for their safety.
● Children should be supervised to ensure that they do not
play with the appliance.

1 2
Read the safety precautions carefully before installing the unit.
Means improper handling may lead to personal death or severe injury.
Means improper handling may lead to personal injury or property loss.
WARNING
CAUTION
Only suitably trained and qualied personnel should install this equipment.
Installation by other non-qualied persons will result in a poor installation, and
Install this product in strict accordance with this manual.
Maintenance, repair or service must be performed by suitably trained
improper service or repair may lead to electric shock or re.
WARNING
Do not install this product adjacent to areas susceptible to ammable gas leaks.
If ammable gases leak near the control, it may cause a re.
Do not operate with wet hands or let water enter the control. Otherwise,
electric shock may occur.
The wiring should be suitably sized for the control current. Incorrectly sized wiring
may overheat and cause a re.
The specied cables shall be applied in the wiring. Do not allow external forces
to pull on the terminals. Damage to the control and overheating may cause a re.
NOTE
2
3
4
2. INSTALLATION ACCESSORIES
1. SAFETY PRECAUTION
1
1
3
4
1
2
1
1
Don’t install in an area contaminated with heavy oils, vapors or gases that may
cause the control to deform, this may lead to a system malfunction.
Select the appropriate installation location
Preparation before installation
1. Please conrm that the following parts have been supplied.
2. Additional eld supplied requirements.
Wired programmable control
1
Lithium battery
No.
No.
Name
Name
Qty.
Qty.
Remark
Remark
To mount the control
To dismantle the control assembly
Phillips screwdriver
Slotted screwdriver
Installation & owner’s manual
Connecting wiring loom
Stated below are important safety issues that must be obeyed.
possibly electric malfunction, shock, re or personal injury.
and qualied personnel, in accordance with the maintenance instructions
1
Part Number B026004
2
1
1To connect to the indoor unit

3. INSTALLATION METHOD
3 4
2. INSTALLATION ACCESSORIES
Wired programmable control installation precautions.
1. This manual describes the installation method of the control. Please refer to the
wiring diagram in this installation manual to wire the control to the indoor unit.
2. The wired control works in a low voltage loop circuit. Do not connect the control
directly to mains voltage (240V), or to three phase power (415V) as it will damage
the control. Ensure that the control wiring (low voltage loop) and any mains cables
are adequately separated.
3. A 6 metre wired control wiring loom is provided with plugs with the wired control.
4. The wired control wiring between the control and the indoor unit can be made
Installation diagram
Fig 3-1
main board
Interconnecting wiring loom
Fig 3-2
1. Connect the female wiring connector from the indoor unit main board
with the male connector of the interconnecting wiring loom. (See Fig.3-1)
2. Connect the other end of the interconnecting wiring loom to the male
wiring connector from the wired control. (See Fig.3-1)
3. Remove the control cover at the bottom with the screwdriver. (See Fig.3-2)
longer than the 6 metres provided, but cannot be more than 20 metres in length.
Indoor unit
male female
male female

5 6
Install the battery in the rear of the control, make sure the positive side
of the battery is correctly aligned on the positive side of the battery
connection. (See Fig.3-3)
4.
Fig 3-3
3. INSTALLATION METHOD
Fig 3-4
NOTE
5. Fix the bottom cover to the electric cabinet with the slotted head screws.
Align the bottom cover so it is level on the wall surface, then reinstall the bottom
cover of the wall control. (See g 3-4)
Over tightening the mounting screws will damage the control and LCD screen.
When installing, please ensure that the screws and wired control are at the same
height without protruding and deforming the control LCD screen.
When installing, please ensure that there is a small loop of excess cable available
3. INSTALLATION METHOD
.
to facilitate removal of the control for maintenance service or repair.
Optional Control extension mounting box

7 8
4 . WIRED PROGRAMMABLE CONTROL WIRING
DIAGRAM
5. SPECIFICATION
1. Wiring diagram of wired control, showing connection with indoor unit
Fig 4-1
DC 12V
o
-5 ~ 43 C
RH 40% ~ RH 90%
Input voltage
Temperature Range
Humidity Range
The pictures in this manual are diagrammatic for explanation
purposes only. The wired control may appear slightly
Indoor Unit
Main PC board
on main PC Board
Cn40 connector
4-core shielded
Rear of
wired control
(See g 4-1)
control box
cable to control
6 metre cable
provided
Operational Limits
different to that as shown.

7. BUTTON DESCRIPTION
1 Operating mode indicator
2 Fan speed indicator
3 Left-right swing indicator
4 Vertical swing indicator
5 Function not applicable
6 Follow me indicator
7 Temperature C°/F° indicator
1 2 3 4 5 6
7
8
9
10
11
13 12
8 Temperature display
9 Lock indicator
10 Room temperature indicator
11 Clock display
12 On/Off timer
13 Timer display
1
2
3
4
5, 6
7
8
9
10 11
POWER
MODE
12
FAN SPEED
TIMER SWING SWING FOLLOW ME
DELAY/DAY OFF CONFIRM BACK COPY
6. LCD DISPLAY LAYOUT
9 10
13

2 MODE
3 Adjustment up and down
4 FAN SPEED
5 Vertical airow direction and swing
6 Horizontal swing
7 FOLLOW ME
8 TIMER
9 DELAY/DAY OFF
10 CONFIRM
11 BACK
12 COPY
13 Remote receiver (some models)
8. PREPARATORY OPERATION
Press the TIMER button for 3 seconds or more.
The timer display will ash.
Press the “+” or “-” adjust buttons to set the current time.
Press repeatedly to adjust the time in 1 minute increments.
Press and hold to adjust the time rapidly.
ex.Monday AM 11:20
1
2
3
4
5
Press the “ + ” or “ - ” adjust buttons to set the date.
The selected date will ash.
After setting the day and time, press the TIMER button to exit. The
control will exit if no buttons are pressed within 10 seconds.
The setting is complete after pressing TIMER button or if no
buttons are pressed within 10 seconds.
Set the current day and time
TIMER
TIMER
11
7. WIRED CONTROL BUTTON DESCRIPTION
12

To start/stop operation
Press the POWER button.
Operation lamp
System ON : Lamp is lit
System OFF : Lamp is not lit
To set the operation mode
Press the MODE button to set the operation mode.
Room temperature setting
Press the “ + ”or “ - ” adjust buttons to set the room
Indoor Setting Temperature Range :
o
17~30 C
Down
Operation mode setting
Up
POWER
Fan speed setting
Press the FAN SPEED button to set the fan speed.
(This function is unavailable in AUTO or DRY modes)
Room temperature sensor selection
Indoor Unit
Press the FOLLOW ME button to select whether
the room temperature is detected up at the
indoor unit or at the wired control position.
When the Follow me function indication is lit, the room
temperature is being detected at the wired control.
FAN SPEED
14
9. OPERATION 9. OPERATION
13
temperature :

9. OPERATION 9. OPERATION
Press the “+” and “-” adjust buttons simultaneously for 3 seconds to activate
the child lock function. This will lock all buttons on the wired control.
Press the same buttons again for 3 seconds to deactivate the child lock.
When the child lock function is activated, the indicator appears.
Keypad tone setting
Press the “BACK” and “COPY” button simultaneously for 3 seconds to
turn off the keypad tone.
Press the same buttons again for 3 seconds to turn on the keypad tone.
BACK
Left-Right swing (applicable products)
Press the button to start Left-Right swing function.
Press the button again to stop.
When the Left-Right swing function is activated, the indicator
15 16
°C & °F temperature scale selection
Press and hold and buttons together
for 3 seconds will alternate the temperature display
o o
between the C and F
SWING SWING
SWINGSWING
appears.
Child lock function
Indice
Manuali Router di rete popolari di altre marche

NETGEAR
NETGEAR FS526T - Switch Manuale utente

Korenix
Korenix JetNet 5710G Series Manuale utente

Automated Logic
Automated Logic ZN551 Manuale del proprietario

Cisco
Cisco ASR 1000 Series Manuale dell'operatore

EnGenius
EnGenius ESR-9710 Manuale utente

Cisco
Cisco 805 Series Istruzioni operative e di sicurezza