Description 1
CCD Camera EDV-No.: MD.167.01.07/2.6.8 Chapter: 1.0
CCDPro 30000/5000 Date: 30.03.2011 Page: 2/2
It is important that both edges must always lie within the visual
range of the camera when using a single camera for width
measurement or web centre control. One edge must lie within each
of the camera’s visual range when using two cameras. This must
be guaranteed if the web position fluctuates.
Reflection copy light process: the light source and the camera
must be positioned on the same side of the material web that has
to be scanned. The camera records the light from the light source
that is reflected from the material web. The reflection copy process
enables lines, grooves, creases, etc., to be recorded as well.
All of the data coming from and going to the camera is transferred
via a CAN-interface.
A keypad with 8 keys and a graphics display is used for executing
the basic operating functions and displaying the web position(s).
1.3 Safety information
The safety relevant information in accordance with DIN EN ISO
13857, EN 349 and the industry specific safety regulations must be
taken into consideration when installing the BST-eltromat
equipment in the production machine, these include:
•There must be a safe distance between the BST-eltromat
equipment and the machinery already installed on-site, such as
machine panels, building structure, etc.
•The interconnecting lines between the control equipment and
the control components or edge sensors must be laid so that
nobody can trip over them, they are not taught and they are well
anchored.
Only trained specialist personnel are permitted
to carry out the assembly, installation and
commissioning!
The mains power must be switched off before the
equipment is opened.
If it becomes necessary to work on the open
equipment with voltage applied, then only Protection
class IP 20 is provided.
There is always increased danger because of the
mains voltage!
1.4 Emissions
The A-evaluated equivalent continuous noise level generated by
the equipment is les than 70 dB(A).