Contents
GeneralSafetyInstructions 3
ConditionsofUse 3
ElectricalSafety 4
SafeOperatingPractices 5
BatteryInformation 7
Introduction 8
Performance 8
InstallationInstructions10
PhysicalAppearance11
FrontPanelOperationalIndicators12
Operation13
Specification14
Maintenance15
SoftwareInstallation16
Loadconfigurereference20
Troubleshooting21

A: 8 Distribuon Pl, Seven Hills NSW 2147
Customer Care New Zealand P: 8 0077 6969 F: 8 0088 6969 E: [email protected]o.nz W: cabac.co.nz
3
3 of 21
General safety instructions
This manual contains important safety instructions that should be followed
duringtheinstallationandmaintenanceoftheUPS.
Pleasereadthismanualthoroughlybeforeattemptingtoinstalloroperatethis
UPS.
DO NOTunder any circumstances attempt to remove the UPS cover. It may
containhazardousvoltagesinternallythatmaycauseelectricshock.Thereare
no userserviceable parts inside. For service, please contact your nominated
serviceagent.
Conditions of Use
This equipment is designed for domestic use only. Themanufacturer neither
recommends nor knowingly sells this product for use in critical life support
applications.
1. Intendedforinstallationinacontrolledenvironment.
a. Thecontrolledenvironmentshouldbeinaccordancewith
therequirementofthespecification
b. DonotinstalloroperateyourUPSinornearwater.
c. DonotplaceUPSonanunstablecart,standortable.
d. Do not place UPS under direct sunlight or close to heat
emittingsources.
e. DonotplaceUPSpowercordinanyareawhereitmayget

A: 8 Distribuon Pl, Seven Hills NSW 2147
Customer Care New Zealand P: 8 0077 6969 F: 8 0088 6969 E: [email protected]o.nz W: cabac.co.nz
4
4 of 21
damagedbyheavyobjects.
2. Placing magnetic storage media on top of the UPS may result in data
corruption.
3. YourUPSprovidesconditionedpowertoconnectedequipment.Maximum
load must not exceed that shown on the UPS rating label. If uncertain,
contactLegend
Electrical Safety
DO NOTunder any circumstances attempt to remove the UPS cover. It may
containhazardousvoltagesinternallythatmaycauseelectricshock.Thereare
no userserviceable parts inside. For service, please contact your nominated
serviceagent.
1. TheCabacUPSwillprovidea220~240VAC1φ(singlephase)ratepower
source.PleaseverifythatthismodelmatchesyourACmains/loadvoltage
requirements.
2. TheCabacUPSmustbeearthedatalltimesduringoperation.Thiscanbe
achieved by only connectingthe input power chord to a mains supply
socketoutletwithanintegralearthterminal.Ameansofdisconnectingthe
mainssupplyshouldbewithin2metersoftheUPS.
3. OutputsocketsontheUPSareelectricallyliveiftheUPSisswitchedON,
eveniftheUPSisnotpluggedintomainssupply.TheOn/Off button on

A: 8 Distribuon Pl, Seven Hills NSW 2147
Customer Care New Zealand P: 8 0077 6969 F: 8 0088 6969 E: [email protected]o.nz W: cabac.co.nz
5
5 of 21
theUPSdoesnotelectricallyisolatetheinternalparts.ToisolatetheUPS,
switchtheUPSOFFfirst,thenunplugitfromthemains.
4. Toreducetheriskoffire,usefuseswiththecorrectratingwhenreplacing
fuses.
5. TheUPSreliesonyourbuildingwiringovercurrentprotection,whichmust
beratedbetween1016amperes.
6. When using the communication features on the UPS, ensure the cabling
connectedtotheUSBcommunicationportarekeptseparatedbyatleast
25mmfromthepowercordstoandfromtheUPSinputandoutput.
Safe Operating Practices
ThispluggabletypeAequipmenthasfactoryinstalledbatteries,andhencemay
beoperatedbyanyonethathasreadandunderstoodthismanual.
Duringtheinstallationofthisequipment,itshouldbeassuredthatthesumof
the leakage currents of the UPS and the connected loads does not exceed
3.5mA.
1. The mains socketoutletthat suppliestheUPSshallbeinstallednearthe
UPSandshallbeeasilyaccessible.
2. When replacing batteries, replace with the same type and number of
batteries.
3. TurnoffandunplugyourUPSbeforecleaning.Donotuseliquidoraerosol
cleaners.Adryclothisrecommendedtoremovedustfromthesurfaceof
yourUPS.
4. Do not handle any metallic connector before the power has been

A: 8 Distribuon Pl, Seven Hills NSW 2147
Customer Care New Zealand P: 8 0077 6969 F: 8 0088 6969 E: [email protected]o.nz W: cabac.co.nz
6
6 of 21
disconnected.
5. TurnoffandunplugyourUPSfromtheoutletandcontactyournominated
serviceagentif:
oThepowercordorplugdamaged.
oLiquidhasbeenspilledontheUPS.
oThefuseblowsfrequently.
oThe UPS does not operate even when user follows the
operatinginstructions.

A: 8 Distribuon Pl, Seven Hills NSW 2147
Customer Care New Zealand P: 8 0077 6969 F: 8 0088 6969 E: [email protected]o.nz W: cabac.co.nz
7
7 of 21
Battery Information
1. CAUTION:Donotdisposeofbatteriesinafire,thebatterymayexplode.
2. CAUTION: Do not open or damage the battery or batteries,asreleased
electrolyteisharmfultotheskinandeyes.
3. Abatterycanpresentariskofelectricshockandhighshortcircuitcurrent.
Thefollowingprecautionshouldbeobservedwhenworkingonbatteries:
Remove watches, rings or other metal objects. Use tools with insulated
handles.
4. NOTE. The batteries used in your CabacUPS aremaintenance free. This
meansthatyouDONOTneedtocheckthebatteryfluidlevels.Tryingtodo
so may cause injury to yourself, or may cause a fault with the battery/
UPS.
5. The battery backup runtime is affected by the state of charge of the
batteries,theageofthebatteriesandgeneralconditionofthebatteries.

A: 8 Distribuon Pl, Seven Hills NSW 2147
Customer Care New Zealand P: 8 0077 6969 F: 8 0088 6969 E: [email protected]o.nz W: cabac.co.nz
8
8 of 21
Introduction
The CabacUPScan instantly switch your computer to emergency battery
backup power and allows you to work through mains power outages without
datalossor downtime.Itcontinuouslyconditionsthe power comingintoyour
computerandprovidesapowersourcewithvirtuallyzerointerruption.
This UPSis specially designed for PC users and also suitable for computer
peripheralsorPOS.Amicrocontrollerisusedasthemaincontrollerthatrenders
theproductanintelligentUPS,capableofselfprotectionandfaultdiagnosis.A
builtinAVRfunctionautomaticallyadjustsitselftomaintainapowersupplyof
stable voltage when the utility power is of high or low voltage.
Highperformance surge suppression protects your computer from electrical
noiseanddamagingpowersurges.
Performance
YourCabacUPSprovidesthefollowinghighperformancefeatures:
•UninterruptiblePower
Protectsyourdatabysupplyingbatterybackupwhenpowerfails.
•MicrocontrollerControl
Bymeans ofinnovativesoftwarecontrolprograms, the complicatedhardware
circuitry is inlaidin the powerful microcontroller. Apart from reduced size, it
alsolowerstherateofUPSfailure.
•LEDIndicators
Operationalstatusisindicatedbyaseriesof3easytoreadLED’s.

A: 8 Distribuon Pl, Seven Hills NSW 2147
Customer Care New Zealand P: 8 0077 6969 F: 8 0088 6969 E: [email protected]o.nz W: cabac.co.nz
9
9 of 21
•AudibleAlarms
Activelyletsyouknowiftheunitisinbatterymode,ifthebatteryislow,orif
thereisanoverloadcondition.
•Highqualitybattery
The selection of high quality sealed leadacid maintenance free batteries
maximisesthelifespanofthebatteryforprolongedperformanceandenhanced
economicbenefits.
•AutomaticDetection
When the UPS is turnedON, it immediately performs an inspection of the
batterycapacity.
•AutomaticVoltageRegulation
Correctsoverandundervoltages,withoutdrainingthebattery.Thispreserves
batteryresourcesandensuresyourUPSwillprovidetheoptimumruntimeand
optimumvoltagesourceduringapowerblackout.
•SurgeProtection
Protectshardwarefromdamageduetounexpectedpowersurges.
•AutomaticCharge
TheUPSchargesitsbatterywheneveritisconnectedtoutilitypower.TheUPS
canbeineithertheONorOFFmode.
•AutoRestart(ColdStart)
If the UPS has shutdown during a battery backup session due to discharged
batteries, the UPS will automatically restart once mains power has been
restoredtosupplymainspowerandrechargethebatteries.

A: 8 Distribuon Pl, Seven Hills NSW 2147
Customer Care New Zealand P: 8 0077 6969 F: 8 0088 6969 E: [email protected]o.nz W: cabac.co.nz
10
10 of 21
Installation Instructions
1. Inspection
Inspectthe UPS upon receipt.The packagingisrecyclable.Save it for reuseor
disposeofitproperly.EnsuretheUPSisphysicallyundamagedduetotransit.
2. Placement
InstalltheUPSinaprotectedareawithadequateairflow,andawayfromdirect
sunlightandexcessivedust.DonotoperatetheUPSwherethetemperatureand
humidityisoutsidethespecifiedlimitsintheSpecificationsTable.
3. ConnecttoMainsPower
ConnecttheACinputpowercordtoasocketoutlettopoweruptheUPS.
ThebatteryintheUPSwilllosesomechargeduringshippingandstorage.Itwill
rechargecompletely after approximately 8 hours of normal operation. Do not
expectfullbatteryruntimeduringthisinitialrechargeperiod.
4. Connecttheloads
PlugtheloadsintotheoutputsocketsontherearoftheUPS.EnsuretheUPSis
sizedcorrectlysothattheUPSisnotrunatfullloadconstantly.
Caution: NDO NOT connect a laser printer or plotter to the UPS with other
computerequipment.A laser printer or plotter periodically draws significantly
morepowerthanwhenidle,andmayoverloadtheUPS.
Questo manuale è adatto per i seguenti modelli
2
Indice
Manuali UPS popolari di altre marche

Pylontech
Pylontech Victron & Pylontech US5000 Manuale utente

Tecnoware
Tecnoware EVO DSP PLUS MM 6.8 Manuale utente

Mecer
Mecer ME-1000-WTU Manuale utente

Mustek
Mustek PowerMust 530(B) Plus Manuale di installazione e funzionamento

Emerson
Emerson Liebert NXL series Manuale utente

MAKELSAN
MAKELSAN BOXER SERIES Manuale utente