CAME FA70230CB Manuale utente

Swing-gate operator
FA70230CB
INSTALLATION MANUAL
FA01335-EN
EN
English

1
23
5
6
4

p. 3- Manual FA01335-EN - 04/2019 - © CAME S.p.A. - The contents of this manual may change, at any time, and without notice. - Original instructions
GENERAL PRECAUTIONS FOR INSTALLERS
Important safety instructions.
Follow all of these instructions. Improper installation can cause serious bodily harm.
Before continuing, also read the general precautions for users.
Use this product only for its specifically intended use. Any other use is hazardous. • The manufacturer can not be held
liable for any damage caused by improper, unreasonable, and erroneous use. • This manual's product is defined by the
Machinery Directive 2006/42/CE as partly-completed machinery. • Partly-completed machinery is an assembly that
almost constitutes a machine, but which, alone, cannot ensure a clearly defined application. • Partly-completed machinery
is only destined to be incorporated or assembled to other machinery or other partly-completed machinery or apparatuses
to build machinery that is regulated by the Machinery Directive 2006/42/EC. • The final installation must comply with
the Machinery Directive 2006/42/EC and the current European reference standards. • The manufacturer declines any
liability for using non-original products; which would result in warranty loss. • All operations indicated in this manual must
be carried out exclusively by skilled and qualified personnel and in full compliance with current regulations. • Laying of
cables, installation and testing must follow state-of-the-art procedures as dictated by applicable standards and laws. • All
the components (e.g. control panels, photocells, sensitive edges, etc.) necessary for the conformity of the final installation
in accordance with the Machinery Directive 2006/42/EC and with the reference harmonized technical standards are
identified in the CAME products general catalog or in the website www.came.com. • Make sure the mains power supply
is disconnected during all installation procedures. • Check that the temperature ranges given and those of the location
match. • If necessary, add suitable reinforcements to the anchoring points. If necessary, add suitable reinforcements
to the anchoring points. • Make sure that the operator, in the installation place, does not get wet by direct jets of water
(sprinklers, water cleaners, etc.). • Make sure you have set up a suitable dual pole cut off device along the power
supply that is compliant with the installation rules. It should completely cut off the power supply according to category III
surcharge conditions. • Demarcate properly the entire site to prevent unauthorized personnel to enter; especially children
and minors. • In case of manual handling, have one person for every 20 kg that need hoisting; for non manual handling
use proper hoisting equipment in safe conditions. • Use suitable protections to prevent any mechanical hazards due to
persons loitering within the operating range of the operator. • The electric cables must pass through special pipes, ducts
and cable glands in order to guarantee adequate protection against mechanical damage. • The electrical cables must not
touch any parts that may overheat during use (such as the motor and the transformer). • Before the installation, check that
the guided part is in good mechanical condition, and that it opens and closes correctly. • The product cannot automate
any guided part that includes a pedestrian gate, unless the latter can be enabled only when the pedestrian gate is secured.
• Make sure that people cannot be entrapped between the guided and fixed parts, when the guided part is set in motion.
• All fixed controls must be clearly visible after installation, in position that the guided part is directly visible, but far away
from moving parts. In the case of a maintained action command, this must be installed at a minimum height of 1.5 m from
the ground and must not be accessible to the public. • If not already present, apply a permanent tag, that describes how
to use the manual release mechanism, close to the mechanism. • Make sure that the operator has been properly adjusted
and that the safety and protection devices, and the manual release, are working properly. • Before turning over to the final
user, check that the system complies with the harmonized standards and the essential requisites of Machinery Directive
2006/42/CE. • Any residual risks must be indicated clearly with proper signage affixed in visible areas. All of which must
be explained to end users. • Fit, in plain sight, the machine's ID plate when the installation is complete. • If the power-
supply cable is damaged, it must be immediately replaced by the manufacturer or by an authorized technical assistance
center, or in any case, by qualified staff, to prevent any risk. • Keep this manual inside the technical folder along with
the manuals of all the other devices used for your automation system. • Remember to hand over to the end users all the
operating manuals of the products that make up the final machinery.

p. 4- Manual FA01335-EN - 04/2019 - © CAME S.p.A. - The contents of this manual may change, at any time, and without notice. - Original instructions
Main points of danger for people
Do not transit through during maneuvering.
Danger of entrapment.
Danger of hand entrapment.
Danger of foot entrapment.
DISMANTLING AND DISPOSAL
CAME S.p.A. employs an Environmental Management System at its premises. This system is certified and compliant with the UNI EN ISO 14001 regulation
standard to ensure that the environment is respected and safeguarded. Please continue safeguarding the environment. At CAME we consider it one of the
fundamentals of our operating and market strategies. Simply follow these brief disposal guidelines:
DISPOSING OF THE PACKAGING
The packaging materials (cardboard, plastic, and so on) should be disposed of as solid household waste, and simply separated from other waste for recycling.
Always make sure you comply with local laws before dismantling and disposing of the product.
DISPOSE OF RESPONSIBLY!
DISPOSING OF THE PRODUCT
Our products are made of various materials. Most of these (aluminium, plastic, iron, electrical cables) are classified as solid household waste. They can be recycled
by separating them before dumping at authorized city plants.
Whereas other components (control boards, batteries, transmitters, and so on) may contain hazardous pollutants.
These must therefore be disposed of by authorized, certified professional services.
Before disposing, it is always advisable to check with the specific laws that apply in your area.
DISPOSE OF RESPONSIBLY!

p. 5- Manual FA01335-EN - 04/2019 - © CAME S.p.A. - The contents of this manual may change, at any time, and without notice. - Original instructions
PRODUCT DATA AND INFORMATION
Legend
This symbol shows which parts to read carefully.
This symbol shows which parts describe safety issues.
This symbol shows which parts to tell users about.
The measurements, unless otherwise stated, are in millimeters.
Description
Irreversible operator with control board and jointed transmission-arm for swing gates with each leaf up to 2.3 m long.
Intended use
Ideal for applying in private homes and apartment buildings, on small-to-medium gate posts
Any installation and/or use other than that specified in this manual is forbidden.
Description of parts
Gearmotor
1
Cover
2
Control board
3
Release hatch
4
Brace for fastening to gate
5
Joint arm
6
Transmission arm
7
Transformer
8
Gearmotor
9
Rubber shim
10
Brace for fastening to the post
11
Limit-switch microswitch
1
2
11
3
4
6
7
8
10
9
5

p. 6- Manual FA01335-EN - 04/2019 - © CAME S.p.A. - The contents of this manual may change, at any time, and without notice. - Original instructions
Control board
All wiring connections are quick-fuse protected.
For the system to work properly, before fitting any plug-in card, you MUST CUT OFF THE MAIN POWER SUPPLY and remove any batteries.
Before working on the control panel, cut off the mains power supply and remove the batteries, if any.
1
Gearmotor terminals
2
Line fuse
3
Power supply terminal board
4
Terminal board for connecting the transformer
5
Control board fuse
6
Terminal board for connecting control and safety devices
7
programming status warning LED
8
Terminal board for connecting the antenna
9
Connector for plug-in radio frequency card (AF)
10
DIP for programming
11
ACT Trimmer: automatic closing time adjustment
12
Trimmer OP.TIME: adjustment of gearmotor working time
13
Trimmer DELAY 2M: adjustment of the M2 motor closing delay time
14
Button for programming
15
Accessories fuse
24V
TS 5C1 7 2 1 11 10 ES ES 12V 0CT
U V W X Y E L N
L2T L1T
1 32
4
6
8
7
5
1012 11
15
14
13
9

p. 7- Manual FA01335-EN - 04/2019 - © CAME S.p.A. - The contents of this manual may change, at any time, and without notice. - Original instructions
Dimensions
200 235
230
Limits to use
With irreversible gearmotors, an electric lock must be installed.
MODELS FA70230CB
Gate-leaf length (m) 2,3 2 1,5 1
Gate-leaf weight (Kg) 200 215 250 300
Technical data
MODELS FA70230CB
Power supply (V - 50/60 Hz) 230 AC
Motor power supply (V) 230 AC
Board power supply (V) 24 AC
Stand-by consumption (W) 5,5
Power (W) 160
Condenser (µF) 10
Current draw (mA) 1,4
Working temperature (°C) -20 ÷ +55
Torque (Nm) 180
Opening time at 90° (s) 15
Work time (s) 14 ÷ 120
Duty cycle (%) 30
Motor thermal protection (°C) 150
Protection rating (IP) 54
Insulation class I
Reduction ratio (i) 735
Fuse table
MODELS FA70230CB
Line fuse 5 A F
Control-board fuse 315 mA F
Accessories fuse 3.15 A F

p. 8- Manual FA01335-EN - 04/2019 - © CAME S.p.A. - The contents of this manual may change, at any time, and without notice. - Original instructions
Cable types and minimum thicknesses
Cable length (m) up to 20 from 20 to 30
230 V AC Power supply 3G x 1.5 mm2 3G x 2.5 mm2
Power supply to motor 230 V AC 3G x 1.5 mm2 3G x 2.5 mm2
TX Photocells 2 x 0.5 mm2 2 x 0.5 mm2
RX photocells 4 x 0.5 mm2 4 x 0.5 mm2
12 V DC electric lock 2 x 1 mm2 2 x 1.5 mm2
Command and control devices * no. x 0.5 mm2 * no. x 0.5 mm2
*no. = see product mounting instructions - Warning: the cable section is merely indicative as it depends on the motor power and cable length.
When operating at 230 V and outdoors, use H05RN-F-type cables that are 60245 IEC 57 (IEC) compliant; whereas indoors, use H05VV-F-type cables that
are 60227 IEC 53 (IEC) compliant. For power supplies up to 48 V, you can use FROR 20-22 II-type cables that comply with EN 50267-2-1 (CEI).
To connect the antenna, use the RG58 (we suggest up to 10 m).
If cable lengths differ from those specified in the table, establish the cable sections depending on the actual power draw of the connected devices and
according to the provisions of regulation CEI EN 60204-1.
For multiple, sequential loads along the same line, the dimensions on the table need to be recalculated according to the actual power draw and
distances. For connecting products that are not contemplated in this manual, see the literature accompanying said products

p. 9- Manual FA01335-EN - 04/2019 - © CAME S.p.A. - The contents of this manual may change, at any time, and without notice. - Original instructions
INSTALLATION
The following illustrations are just examples, as the space available for fitting the operator and accessories varies depending on the area where it is
installed.
The drawings refer to the left-side gearmotor.
Preliminary operations
Set up the junction boxes and corrugated tubes you will need to make connections coming from the junction pit.
An operator (FA70230CB) and a gearmotor (FA70230) must be installed on two-leaf gates .
FA70230CB must be installed on the leaf that must start the opening maneuver first.
FA70230 must be installed on the leaf that must start the opening maneuver subsequently.
The number of tubes depends on the type of system and the accessories that are going to be fit.
Setting up the gearmotor
Carefully remove the gearmotor cover.
4
2
1
2
3

p. 10 - Manual FA01335-EN - 04/2019 - © CAME S.p.A. - The contents of this manual may change, at any time, and without notice. - Original instructions
Establishing the brackets fastening points
First determine where the gate fastening bracket has to be positioned, then where the brace for fastening to the post has to be positioned.
Respect the values indicated in the table.
Leaf opening
arc (°)
A B D E C Max
90° 140 420 (490 with item 801XC-0070) Min. 200 260 (350 with item 801XC-0070) 200 (300 with item 801XC-0070)
90° 160 380 (460 with item 801XC-0070) Min. 220 240 (320 with item 801XC-0070) 200 (300 with item 801XC-0070)
90° 180 380 (460 with item 801XC-0070) Min. 240 240 (320 with item 801XC-0070) 200 (300 with item 801XC-0070)
110° 220 380 (450 with item 801XC-0070) Min. 280 310 (400 with item 801XC-0070) 50 (50 with item 801XC-0070)
110° 240 380 (450 with item 801XC-0070) Min. 300 310 (400 with item 801XC-0070) 50 (50 with item 801XC-0070)
AB
120 min
C MAX
47,5
E
D
173
94
40
120
100
60
18
Fastening the braces
Drill the fastening points.
Altri manuali per FA70230CB
3
Indice
Altri manuali CAME Apricancello

CAME
CAME BX Series Manuale utente

CAME
CAME FA7024CB Manuale utente

CAME
CAME Ferni Series Manuale utente

CAME
CAME BXL04AGE Manuale utente

CAME
CAME FA4024CB Manuale utente

CAME
CAME F500 Manuale utente

CAME
CAME ATS-S5 KIT Manuale utente

CAME
CAME ATS-S524 KIT Manuale utente

CAME
CAME BX10 Manuale utente

CAME
CAME BK Series Manuale utente

CAME
CAME VER10 Manuale utente

CAME
CAME AMICO Series Manuale utente

CAME
CAME ATI-P3 Manuale utente

CAME
CAME ZCX10 Manuale utente

CAME
CAME BY-3500T Manuale utente

CAME
CAME FROG-AV Manuale utente

CAME
CAME BX708ALS Manuale utente

CAME
CAME F7001 Manuale utente

CAME
CAME ATS30DGS Manuale utente

CAME
CAME STYLO ME Manuale utente