Campbell CS205 Manuale utente

Model CS205 10-Hour
Fuel Temperature Stick
Revision: 5/08
Copyright © 1998-2008
Campbell Scientific, Inc.

Warranty and Assistance
The MODEL CS205 10-HOUR FUEL TEMPERATURE STICK is
warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in
materials and workmanship under normal use and service for twelve (12)
months from date of shipment unless specified otherwise. Batteries have no
warranty. CAMPBELL SCIENTIFIC, INC.'s obligation under this warranty is
limited to repairing or replacing (at CAMPBELL SCIENTIFIC, INC.'s option)
defective products. The customer shall assume all costs of removing,
reinstalling, and shipping defective products to CAMPBELL SCIENTIFIC,
INC. CAMPBELL SCIENTIFIC, INC. will return such products by surface
carrier prepaid. This warranty shall not apply to any CAMPBELL
SCIENTIFIC, INC. products which have been subjected to modification,
misuse, neglect, accidents of nature, or shipping damage. This warranty is in
lieu of all other warranties, expressed or implied, including warranties of
merchantability or fitness for a particular purpose. CAMPBELL SCIENTIFIC,
INC. is not liable for special, indirect, incidental, or consequential damages.
Products may not be returned without prior authorization. The following
contact information is for US and International customers residing in countries
served by Campbell Scientific, Inc. directly. Affiliate companies handle
repairs for customers within their territories. Please visit
www.campbellsci.com to determine which Campbell Scientific company
serves your country. To obtain a Returned Materials Authorization (RMA),
contact CAMPBELL SCIENTIFIC, INC., phone (435) 753-2342. After an
applications engineer determines the nature of the problem, an RMA number
will be issued. Please write this number clearly on the outside of the shipping
container. CAMPBELL SCIENTIFIC's shipping address is:
CAMPBELL SCIENTIFIC, INC.
RMA#_____
815 West 1800 North
Logan, Utah 84321-1784
CAMPBELL SCIENTIFIC, INC. does not accept collect calls.

CS205 Table of Contents
PDF viewers note: These page numbers refer to the printed version of this document. Use
the Adobe Acrobat® bookmarks tab for links to specific sections.
1. General Description.....................................................1
2. Specifications ..............................................................1
3. Installation....................................................................1
4. Wiring............................................................................2
5. Datalogger Programming............................................3
5.1 CR1000 Programming..............................................................................3
5.2 CR10X Programming...............................................................................4
6. Maintenance and Calibration......................................4
Figures
3-1. Exploded View of CS505 and CS205 Mounting ....................................1
3-2. CS205 Mounts on the Mounting Stake with the CS505..........................2
6-1. 107 Thermistor Probe Schematic ............................................................4
Tables
4-1. Wiring for CS205....................................................................................2
This is a blank page.
i


Model CS205 10-hour Fuel Temperature
Stick
1. General Description
The CS205 Temperature Stick is a Ponderosa pine dowel 4.5 inches long and
0.5 inches in diameter. The dowel is fabricated to USFS specifications, to be
used as a fuel moisture sensor. Campbell Scientific, Inc. has bored a hole and
cut a split into one end of the dowel. A model 107 Temperature Probe is
inserted into the CS205 to measure fuel temperature.
The CS205 Fuel Temperature Stick mounts on the 10974 Fuel
Moisture/Temperature Mounting Stake. The CS205 is most commonly
installed along with a CS505 Fuel Moisture Sensor but can be used alone.
2. Specifications
Fuel Temperature Stick
Diameter 0.5 inches
Length 4.5 inches
Wood Type Ponderosa Pine
Bore Hole about 1/4 inch
3. Installation
Insert a 107 temperature probe into the CS205 Fuel Moisture Stick. The
CS205 installs in the white compression fitting on the 10974 Fuel Moisture/
Temperature Mounting Stake. Loosen the compression fitting so that the
CS205 can be inserted. The CS205 inserts into the compression fitting so that
compression is applied to the split end of the stick gripping the 107 probe.
Please refer to the 107 probe manual for a complete discussion of the 107
probe.
FIGURE 3-1. Exploded View of CS505 and CS205 Mounting
1

Model CS205 10-hour Fuel Temperature Stick
FIGURE 3-2. CS205 Mounts on the Mounting Stake with the CS505
4. Wiring
Connections to Campbell Scientific dataloggers are given in Table 4-1.
Temperature is measured with one Single-Ended input channel and an
Excitation channel.
TABLE 4-1. Wiring for CS205
Color
Description
CR800
CR5000
CR3000
CR1000
CR510
CR500
CR10(X)
CR21X
CR7
CR23X
Black Excitation Switched
Excitation Switched
Excitation Switched
Excitation
Red Temperature
Signal Single-Ended
Input Single-Ended
Input Single-Ended
Input
Purple Signal Ground
AG
Clear Shield
G
Please refer to the 107 probe manual for a complete discussion of the 107
probe.
2

Model CS205 10-hour Fuel Temperature Stick
5. Datalogger Programming
This section is for users who write their own datalogger programs. A
datalogger program to measure this sensor can be created using Campbell
Scientific’s Short Cut Program Builder software. You do not need to read this
section to use Short Cut.
The Temp107 measurement instruction (P11), is used with dataloggers that are
programmed with Edlog (e.g. CR10X, CR23X) to measure the 107 probe. P11
makes half bridge voltage measurement, and converts the measurement result
to temperature using a fifth order polynomial. With a multiplier of 1 and an
offset of 0, the output is temperature in degrees C. With a multiplier of 1.8 and
an offset of 32, the output is temperature in degrees F.
The Therm107 measurement instruction is used with dataloggers that are
programmed with CRBasic (e.g. CR1000) to measure the 107 probe.
Therm107 makes a half bridge voltage measurement, and converts the
measurement result to temperature using the Steinhart-Hart equation. With a
multiplier of 1 and an offset of 0, the output is temperature in degrees C. With
a multiplier of 1.8 and an offset of 32, the output is temperature in degrees F.
5.1 CR1000 Programming
'CR1000
'This example program measures a single 107 Thermistor probe
'every 10 seconds and stores the average temperature every 60 minutes.
'Declare the variables for the temperature measurement
Public T107_C
'Define a data table for 60 minute averages:
DataTable(Table1,True,-1)
DataInterval(0,60,Min,0)
Average(1,T107_C,IEEE4,0)
EndTable
BeginProg
Scan(10,Sec,1,0)
'Measure the temperature
Therm107(T107_C,1,1,Vx1,0,_60Hz,1.0,0.0)
'Call Data Table
CallTable(Table1)
NextScan
EndProg
3

Model CS205 10-hour Fuel Temperature Stick
5.2 CR10X Programming
;{CR10X}
*Table 1 Program
01: 10 Execution Interval (seconds)
1: Temp (107) (P11)
1: 1 Reps
2: 1 SE Channel
3: 21 Excite all reps w/E1, 60Hz, 10ms delay
4: 1 Loc [ T107_C ]
5: 1.0 Multiplier
6: 0.0 Offset
3: If time is (P92)
1: 0 Minutes (Seconds --) into a
2: 60 Interval (same units as above)
3: 10 Set Output Flag High (Flag 0)
4: Set Active Storage Area (P80)
1: 1 Final Storage Area 1
2: 101 Array ID
5: Real Time (P77)
1: 1220 Year,Day,Hour/Minute (midnight = 2400)
6: Average (P71)
1: 1 Reps
2: 1 Loc [ T107_C ]
6. Maintenance and Calibration
The 107 Probe requires minimal maintenance. Please refer to the 107 manual
for more detail.
The CS205 Fuel Moisture Stick should be changed annually or more
frequently as required. The wood should visually appear fresh and new not
gray or discolored.
FIGURE 6-1. 107 Thermistor Probe Schematic
4

This is a blank page.

Campbell Scientific Companies
Campbell Scientific, Inc. (CSI)
815 West 1800 North
Logan, Utah 84321
UNITED STATES
www.campbellsci.com
Campbell Scientific Africa Pty. Ltd. (CSAf)
PO Box 2450
Somerset West 7129
SOUTH AFRICA
www.csafrica.co.za
Campbell Scientific Australia Pty. Ltd. (CSA)
PO Box 444
Thuringowa Central
QLD 4812 AUSTRALIA
www.campbellsci.com.au
Campbell Scientific do Brazil Ltda. (CSB)
Rua Luisa Crapsi Orsi, 15 Butantã
CEP: 005543-000 São Paulo SP BRAZIL
www.campbellsci.com.br
Campbell Scientific Canada Corp. (CSC)
11564 - 149th Street NW
Edmonton, Alberta T5M 1W7
CANADA
www.campbellsci.ca
Campbell Scientific Ltd. (CSL)
Campbell Park
80 Hathern Road
Shepshed, Loughborough LE12 9GX
UNITED KINGDOM
www.campbellsci.co.uk
Campbell Scientific Ltd. (France)
Miniparc du Verger - Bat. H
1, rue de Terre Neuve - Les Ulis
91967 COURTABOEUF CEDEX
FRANCE
www.campbellsci.fr
Campbell Scientific Spain, S. L.
Psg. Font 14, local 8
08013 Barcelona
SPAIN
www.campbellsci.es
Please visit www.campbellsci.com to obtain contact information for your local US or International representative.
Altri manuali per CS205
1
Indice
Altri manuali Campbell Regolatori di temperatura

Campbell
Campbell 110PV Manuale utente

Campbell
Campbell Wintersense Manuale utente

Campbell
Campbell IR100 Manuale del proprietario

Campbell
Campbell ASPTC Manuale del proprietario

Campbell
Campbell CS225 Manuale utente

Campbell
Campbell HygroVUE 5 Manuale utente

Campbell
Campbell CS240 Manuale utente

Campbell
Campbell IR100 Manuale utente

Campbell
Campbell CS241 Manuale utente

Campbell
Campbell IRTS-P Manuale utente