MAP2 Elevator Control
INSTALLATION GUIDE
April 2020

MAP2 Elevator Control Page 2 of 16
Installation Guide April 2020 • Rev. 1.0
Table of Contents
Introduction .............................................................................................................................................................. 3
Overview ................................................................................................................................................................... 4
Requirements ........................................................................................................................................................... 4
H1000 Panel Layout ................................................................................................................................................. 5
Elevator Control Configurations and Wirings........................................................................................................ 6
16 Floor Elevator System.........................................................................................................................6
32 Floor Elevator System.........................................................................................................................7
48 Floor Elevator System.........................................................................................................................8
64 Floor Elevator System.......................................................................................................................10
MAP2 and H1000 Control Panel LED Indicators...................................................................................................12
MAP2 PLM Communication................................................................................................................13
MAP2 to H1000 Panel Communication LEDs.......................................................... 13
H1000 EX1000 Communication..........................................................................................................14
H1000 to MAP2 Communication LEDs....................................................................14
H1000 RD8, RD7, RD6 LEDs ...................................................................................14
Connection to the Elevator Controls .....................................................................................................................15
Isolating relays........................................................................................................................................15
Safety ......................................................................................................................................................15
Fire Alarm ..............................................................................................................................................15
Service Override Switch.........................................................................................................................15
Host Communication Wiring ..................................................................................................................................16
Wiegand-Compatible Reader Wiring .....................................................................................................................16
© Copyright 2020 Cansec Systems, Ltd.

MAP2 Elevator Control Page 3 of 16
Installation Guide April 2020 • Rev. 1.0
Introduction
The MAP2 elevator controller has been designed to handle access up to 64 floors with the add-on
H1000 panels. In the elevator application, the credential owners simply present their credentials to the
reader mounted inside the elevator cab to gain access to their assigned floors. This prevents access to
unauthorized elevator floors and at the same time allows the building owner to isolate different
organizations that cohabit the same building.
The MAP2 elevator controller is a cost effective solution allowing the building owner to purchase the
correct number of controllers required to control the number of elevator floors. A single MAP2
elevator controller can control up to 16 floors. However, the add-on H1000 panels may be added to
accommodate 32, 48 and 64 floors.
Elevator MAP2 Panel
H1000 Panel
H1000 Panel
H1000 Panel
Floors 1-16
Floors 17-32
Floors 33-48
Floors 49-64
Optional: H1000 Panels
Elevator MAP2 Panel
Elevator MAP2 Panel must be provisioned by Cansec each time an additional add-on H1000 is added

MAP2 Elevator Control Page 4 of 16
Installation Guide April 2020 • Rev. 1.0
Overview
The MAP2 elevator control panel and the H1000 panel are designed to interface with the elevator
electronics using the “Form C” relay output contacts of the panels. These relay output contacts make
or break the connection to individual elevator floor buttons. The connection to these buttons is
provided by the elevator company.
The Wiegand Reader (located in the elevator cab) requires 6 conductors which will be connected to the
elevator travel cable used by the elevator. The elevator travel cable terminates in the elevator control
room, and from this location the 6 reader wires will be used to connect to the reader port of the MAP2
Elevator control panel.
The “Form C” relay output contacts of the MAP2 and H1000 panels are designed to switch only low
voltage. An Elevator Relay Interface Box is required to make the actual connection to the floor buttons
in the elevator electronics. The Elevator Relay Interface Box must be supplied by the elevator
contractor. 12 volt relays are to be used in the interface box. The MAP2 and H1000 panels’ output
relay contacts will switch the 12 volt coil of the relay in the interface box.
Under no circumstance is 110/120 or higher voltage to be present in the access control panel (many
elevators use 110Volts AC or DC in the floor button circuitry which is considered a lethal voltage). A
service bypass switch must be installed in the Elevator Relay Interface Box to allow for fire alarm release
of all the floors in the event of a fire alarm and to allow service of either the access control system or
the physical elevator. If a bypass switch is not installed, both technical parties need to be present during
service of either the access control system or the elevator, and that can be quite costly.
Requirements
Wiegand reader mounted inside the elevator cab.
Elevator Relay Interface Box, supplied by elevator contractor.
MAP2 and optional H1000 controllers mounted in the elevator control room.
Refer to reader manufacturer for reader wire specifications.
MAP2 and H1000 relays should be used to switch low DC voltage, e.g. 12VDC.
Optional H1000 V1.1 controller and daughter card EX100 V1.1.
MAP2 Elevator Control Panel
Wiegand Reader
6 conductors
Travel Cable
6 conductors
Elevator Cab

MAP2 Elevator Control Page 5 of 16
Installation Guide April 2020 • Rev. 1.0
H1000 Panel Layout

MAP2 Elevator Control Page 6 of 16
Installation Guide April 2020 • Rev. 1.0
Elevator Control Configurations and Wirings
16 FLOOR ELEVATOR SYSTEM
This configuration is used when connecting to an elevator system of up to 16 floors. This consists
of one MAP2 elevator control panel.
Create Panel
Define Floor Group
Floor Group Assignment
See First Access Operator Guide for more details

MAP2 Elevator Control Page 7 of 16
Installation Guide April 2020 • Rev. 1.0
32 FLOOR ELEVATOR SYSTEM
This configuration is used when connecting to an elevator system of up to 32 floors. This consists
of one MAP2 elevator control panel and one H1000 panel.
MAP2 Elevator Panel
H1000 Panel
RS485 communication wires
Controls floors 1 to 16
Controls floors 17 to 32
See First Access Operator Guide for more details
Create Panel
Define Floor Group
Floor Group Assignment
1. Dipswitch Settings:
OPT1: ON
OPT2: OFF
OPT3: OFF
OPT4: OFF
2. Jumper Setting:
3. Address Setting:
Address set to 1
Create Panel
Elevator MAP2 Panel must be provisioned by Cansec each time an additional add-on H1000 is added

MAP2 Elevator Control Page 8 of 16
Installation Guide April 2020 • Rev. 1.0
48 FLOOR ELEVATOR SYSTEM
This configuration is used when connecting to an elevator of up to 48 floors. This consists of one
MAP2 elevator control panel and two H1000 panels.
H1000 Panel 1
H1000 Panel 2
1. Dipswitch Settings:
OPT1: OFF
OPT2: ON
OPT3: OFF
OPT4: OFF
1. Dipswitch Settings:
OPT1: ON
OPT2: OFF
OPT3: OFF
OPT4: OFF
2. Jumper Setting:
2. Jumper Setting:
3. Address Setting:
3. Address Setting:
Panel address is set to 1
MAP2 Elevator Panel
RS485 communication wires
Controls floors 1 to 16
Panel address is set to 1
H1000 Panel 1: Controls floors 17- 32
H1000 Panel 2: Controls floors 13- 48
Elevator MAP2 Panel must be provisioned by Cansec each time an additional add-on H1000 is added

MAP2 Elevator Control Page 9 of 16
Installation Guide April 2020 • Rev. 1.0
Create Panel
Define Floor Group
Floor Group Assignment
See First Access Operator Guide for more details

MAP2 Elevator Control Page 10 of 16
Installation Guide April 2020 • Rev. 1.0
64 FLOOR ELEVATOR SYSTEM
This configuration is used when connecting to an elevator of up to 64 floors. This consists of one
MAP1 elevator control panel and three H1000 panels.
MAP2 Elevator Panel
H1000 Panel 1: Controls floors 17- 32
H1000 Panel 2: Controls floors 33- 48
H1000 Panel 3: Controls floors 49- 64
Controls floors 1 to 16
RS485 communication wires
Elevator MAP2 Panel must be provisioned by Cansec each time an additional add-on H1000 is added