CDVI V1SR Manuale utente

V1SR
V3S
V3SR
V3SRB
V4S
V4SR
V4SRB
V5S
V5SR
V5SRB
V3S - V3SR - V3SRB
V1SR V4S - V4SR - V4SRB
V5SRB
V5S - V5SR - V5SRB
FR
EN
FRANCAIS
ENGLISH
INSTALLATION MANUAL
Range: Locking Devices /
Surface Mount Electromagnetic locks
* Refer to limited lifetime warranty conditions. / Voir conditions de garantie à vie limitée.
MANUEL D’INSTALLATION
Gamme: Verrouillage
Ventouses électromagnétiques appliques

EN
V1SR - V3S - V3SR - V3SRB - V4S - V4SR - V4SRB - V5S - V5SR - V5SRB
Surface mount Electromagnetic locks
INSTALLATION MANUAL
1] PRODUCT PRESENTATION
The V3S, V4S and V5S series
with signalling are suitable for
the new regulations covering
assistance to persons with
reduced mobility.
Thank you for buying our products and for the confi dence you placed
in our company.
180, 300, 400 or 500kg**.
Electronic protection
to eliminate back EMF.
Electromagnetic lock dimensions (L x W x D):
- V1SR = 167 x 34 x 21mm.
- V3S series = 248 x 45 x 26mm,
- V4S series = 255 x 50 x 27mm,
- V5S series = 266 x 66 x 40mm.
Armature dimensions (l x w x d):
- 180kg = 130 x 32 x 9mm,
- 300kg = 185 x 38 x 11mm,
- 400kg= 185 x 45 x 12mm,
- 500kg = 185 x 60 x 12mm.
Silent operation.
Power supply: 12/24V dc.
Power absorption:
- 12 V DC = 550mA,
- 24 V DC = 275mA.
Refs Holding
force
Visual
feedback
Audible
feedback Relay Moni-
tored
V1SR 180 kg
-
- -
V3S 300kg - - -
V3SR 300kg -
V3SRB 300kg
V4S 400kg - - -
V4SR 400kg -
V4SRB 400kg
V5S 500kg - - -
V5SR 500kg -
V5SRB 500kg
EC certifi cation
WEEE
IP42
cdvi.com
cdvigroup.com
COLOUR CODES
BLUE ACTIVE VOLTAGE
RED LOCKED
GREEN OPEN
BLUE LOCKED
GREEN OPEN + BUZZER
RoHS
ARD212 BS60
Recommended
power supplies
* Refer to limited lifetime warranty conditions.
** Depending on the version.
2] REMINDERS AND RECOMMENDATIONS
The function of an electromagnetic lock is to ensure the locking of an access point. This document is a guide
of installation which will allow you to secure the installation according to the characteristics of the product,
the site and the environmental requirements.

EN
V1SR - V3S - V3SR - V3SRB - V4S - V4SR - V4SRB - V5S - V5SR - V5SRB
Surface mount Electromagnetic locks
INSTALLATION MANUAL
3
cdvi.com
cdvigroup.com
POWER SUPPLY
An electromagnetic lock always operates in DC current, a very low safety voltage. The Diax® electromagnetic
lock is recommended for use with power supplies manufactured by CDVI, however, other power supplies
may be used on condition that they are of equivalent quality and characteristics recti ed, ltered, regulated
and protected by fuse in primary and secondary sectors.
MOUNTING RECOMMENDATIONS
- De ne the level of security of the access.
- Determine the maximum strength of holding force to this level of security.
- Select the Diax® electromagnetic lock according to the environment, the inside, the outside, the climatic
constraints, (For example: stainless steel dedicated to an outside use).
- Always install the electromagnetic lock on the secure side of the place to be secured.
- Indeed make sure that the frame and opening, receiving or supporting the electromagnetic lock, armature
plate and their accessories, are solid and resistant to damage or wear over a period of time.
- Consider any bracketry required for the assembly according to the type of support receiving
the electromagnetic lock and armature plate.
- De ne the passage of cables to ensure the protection against the vandalism and the environmental
requirements (in particular through fl exible hoses of door, glands, gutters, cross cables, plastic tubes).
Security ropes
The electromagnetic lock undergoes repeated
shocks and the vibration at the points of fi xation
on the frame (frequencies of openings / closures,
attempt of opening wears closed and attempts
of vandalism) which can loosen the fi xing bolts/
screws. To prevent the risk of the electromagnetic
block from falling, install both security ropes
supplied, to guarantee the safety of the users
(see attached plan).
Security rope
( xing on the magnetic lock and the frame)
APPROVAL RELATIVE TO EMERGENCY EXITS:
In the case of an installation of electromagnetic lock on emergency exits, it is imperative to make sure that
these exit points will be automatically free in case of re alarm, to open in the event of a re alarm to allow
evacuation of the premises. The electromagnetic lock installed on emergency exits must be in accordance
with the re approval department (Ex: In France = NF 61-937).
For more information, contact CDVI, the local fi re offi cer or the safety offi cer responsible for the building.
Armature plate
- It is vital to fi x the electromagnetic lock
and armature plate solidly on their supports.
- Make sure that the magnet and the armature
meet evenly over their entire mating surfaces.
- The Armature plate must be able to pivot
slightly about its center mounting screw
to compensate for any door misalignment.

EN
V1SR - V3S - V3SR - V3SRB - V4S - V4SR - V4SRB - V5S - V5SR - V5SRB
Surface mount Electromagnetic locks
INSTALLATION MANUAL
4cdvi.com
cdvigroup.com
3] PACKAGE CONTENTS
Surface
mount
magnetic
lock
Armature
plate Fixing
plate Roll pin
5x16 Steel
washer
4x25
wood
screw
Key
3mm Key
5mm
11122711
M8x35
screw M8x25
screw
3x8
self-tapping
screw
Guide
piece Cap
nut Safety
rope
Rubber
washer
Installation
manual
11111211
Surface
mount
magnetic
lock
Armature
plate Fixing
plate Roll pin
5x16 Steel
washer
3x25
wood
screw
Key
3mm Guide
piece Cap
nut Installation
manual M5x20
screw
11122511111
ELECTROMAGNETIC LOCK V1SR
ELECTROMAGNETIC LOCK V3S - V3SR - V3SRB - V4S - V4SR - V4SRB - V5S - V5SR - V5SRB
MAINTENANCE
The Electro magnet and armature plate have a speci c treatment which strengthens the protection against wear
and corrosion. These products do not require high maintenance. Nevertheless to ensure optimum performance,
it is recommended to clean regularly the surfaces in contact of the electro magnet and armature plate with a cloth
and non abrasive products. If traces of corrosion appear, it is recommended to clean and oil the contact surfaces.
Check and tighten regularly all the xings of the Electro magnet and ensure that while the armature is able to pivot
on its mounting, the xing bolt is not liable to loosen (we recommend thread-lock for all xing bolts).

EN
V1SR - V3S - V3SR - V3SRB - V4S - V4SR - V4SRB - V5S - V5SR - V5SRB
Surface mount Electromagnetic locks
INSTALLATION MANUAL
5] ELECTRICAL CONNECTIONS
The NO/NC signal only switches when the door is closed with the power to it on.
TERMINAL
BLOCK CORRESPONDENCE V3S
V4S - V5S V3SR - V3SRB - V4SR
V4SRB - V5SR - V5SRB
+12 or 24V dc
-- 0 V
N.C NC (Normally closed) -
COM COM -
N.O NO (Normally open) -
WITH BUILT-IN PCB BOARD
12V dc
Factory
Setup
12V dc 12V dc24V dc 24V dc 24V dc
Voltage selection jumpers
Voltage selection jumpers
Voltage selection jumpers
5
cdvi.com
cdvigroup.com
4] OPTIONAL ACCESSORIES
References L3L4L5 Z3Z4Z5 UBKU UBKP AMA3AMA5 DPM300
DPM500 LZ1
Description L-shaped bracket
for lock Z-shaped bracket
for lock
Armature base
for glass door
Universal base
for glass door Armature base
Door position
monitoring
L & Z-shaped
bracket
for 180kg lock
V3S - V4S - V5S V3SR - V4SR - V5SR
V3SRB - V4SRB - V5SRB
-+
Surface
mount
magnetic
lock
Armature
plate Fixing
plate Roll pin
5x16 Steel
washer
4x25
wood
screw
Key
3mm Key
5mm
11122711
M8x35
screw M8x25
screw
3x8
self-tapping
screw
Guide
piece Cap
nut Safety
rope
Rubber
washer
Installation
manual
11111211

EN
V1SR - V3S - V3SR - V3SRB - V4S - V4SR - V4SRB - V5S - V5SR - V5SRB
Surface mount Electromagnetic locks
INSTALLATION MANUAL
Security
rope
6cdvi.com
cdvigroup.com
6]
INSTALLATION (EXAMPLE: V3S SERIES)
DIRECT CONNECTION
12V DC 24V DC CONTACT
Red Red Yellow NC
Blue COM
Orange NO
++
White White
--
Green Green
Black Black
xing plate Security
rope
Security
rope
Armature plate
M8
screw
Cap nut
Guide piece
Rubber washer
Roll pin
Steel washer Rubber washer
Fixing plate
Door frame
Outwards opening
door (push door).
Electromagnetic
lock
Armature
plate
Cap nut
Guide piece
M8 screw
OUTSIDE
Door
Installation on an outward opening
door (Push door)
Check the jumper position before connecting the lock to the input current.
A wrong position could damage the lock. This type of damage is not covered
by the warranty.
IMPORTANT NOTE

EN
V1SR - V3S - V3SR - V3SRB - V4S - V4SR - V4SRB - V5S - V5SR - V5SRB
Surface mount Electromagnetic locks
INSTALLATION MANUAL
Electromagnetic lock
Armature plate
Adjustable
Inward opening door (Pull door)
(installed with “Z” and “L” brackets)
Z shaped bracket
:
Z3Z4Z5
L shaped bracket
:
- L3L4 (300 - 400 Kg),
- L5 (500kg).
L shaped bracket
Z shaped
bracket
Installation on an inward opening
door (Pull door)
Fixing screw
Rubber washer
Roll pin
Steel washer
Armature plate
M8 screw
DOOR FRAME
OUTSIDE
INSIDE
DOOR
7] INSTALLATION WITH ACCESSORIES
Fixing plate
Security
rope
Security
rope
Security
rope
Security
rope
Armature housing
Armature plate
Rubber washer
Roll pin
Steel washer
Armature
screw
Outwards opening door (push door).
(installed with armature housing)
OUTSIDE
INSIDE
Installation with an Armature
housing
Armature housing
AMA3 or AMA5
DOOR FRAME
Electromagnetic
lock
DOOR
EXT.
opening
7
cdvi.com
cdvigroup.com

EN
V1SR - V3S - V3SR - V3SRB - V4S - V4SR - V4SRB - V5S - V5SR - V5SRB
Surface mount Electromagnetic locks
INSTALLATION MANUAL
8cdvi.com
cdvigroup.com
Fixing plate Security
rope
Security
rope
Armature housing for glass door
UBKU
Rubber washer
Roll pin
Steel washer
Armature
screw
Outward opening door (Push door)
(installed with UBKU brackets)
Installation with base for glass door
OUTSIDE
INSIDE
DOOR FRAME
Electromagnetic lock
Universal base for glass
door UBKU
DOOR
Fixing plate
Armature
plate
DOOR
GLASS
FRAME
Adjustable
UBKP
Inward opening door (Pull door)
(installed with “UBKP”, “L3L4L5”
and Z3Z4Z5 brackets)
Installation with base
for glass door
Universal
housing for
glass door
UBKP
Rubber washer
Steel washer
Armature
plate
Armature
screw
Security
rope
Security
rope
Roll pin
OUTSIDE
INSIDE
Z shaped bracket
Z3Z4Z5
L shaped bracket
:
- L3L4 (300 - 400 Kg),
- L5 (500kg).

FR
V1SR - V3S - V3SR - V3SRB - V4S - V4SR - V4SRB - V5S - V5SR - V5SRB
Ventouses électromagnétiques appliques
MANUEL D’INSTALLATION
8] FAULT FINDING
Installation with DPM300 - DPM400 - DPM500 (Door position monitoring)*
Roll pin
Armature plate Electromagnetic lock
DPM300
Fixed on the armature
DPM300
Fixed on the
electromagnetic lock
PROBLEM POSSIBLE CAUSE SOLUTION
Door
locking
impossible
The lock is not receiving
DC current.
- Check that the wires are connected to the right
terminals.
- Check that the power supply is compatible.
- Check that the lock is connected to the circuit
correctly.
Holding
force
reduced
The lock and the armature are
not lined up with each other.
- Check that the lock is connected to the circuit
correctly.
- Check that the electromagnet and the armature
are properly aligned.
- Check that the contact faces are free from dirt and rust.
- Check that the armature is soft mounted.
Low voltage or armature
jammed.
- Check that the lock is receiving the correct power
supply satisfactorily.
- check the tightening of the armature
and the condition of the rubber.
Faulty
reed
switch
Voltage too low. Misalignment.
- Check the power supply.
- Cable cross section to be determined according
to the power supply and the locking.
- e.g.: 2 x 1.5mm2 ≥ 10m.
9
cdvi.com
cdvigroup.com
* Optional. Sold separately.

EN
9] LIMITED LIFETIME WARRANTY [EXTRACT]*
CDVI warrants this product to be free from defects in material and workmanship, when it has been installed
in accordance with the manufacturer’s instructions and has not been modi ed or tampered with. Only product
recognized by CDVI to be defective should be returned under these warranty terms if accompanied
by an RMA (Return Material Authorization Number) provided by CDVI. CDVI, at its option, shall repair
or replace the defective product at CDVI premises or at any CDVI approved service center. This warranty
does not cover any damage due to accident, misuse, abuse or negligence. This warranty is valid only
if the product is registered, within 1 month from delivery to the nal costumer. To obtain full details of this
warranty and to register the product to commence the “Limited Lifetime Warranty”, complete the enclosed
registration card and return it, either by e-mail or post, to the relevant CDVI address or completion of the
on line registration at www.cdvigroup.com. Repair or replacement of the defective product is the exclusive
remedy. CDVI shall not be liable for any incidental or consequential damages arising from any defect in, or
malfunction of, its product. In no event the entire liability can not exceed the purchase price of the product.
The CDVI local country contact details can be found on line by visiting www.cdvigroup.com or on the back
cover of the installation manual.
DISCLAIMER OF WARRANTY: EXCEPT AS STATED ABOVE, CDVI MAKES NO WARRANTIES, EITHER
EXPRESS OR IMPLIED, AS TO ANY MATTER WHATSOEVER, INCLUDING THE CONDITION OF ITS PRODUCTS,
THE TRANSPORTATION, THEIR MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.
10] NOTES
* Refer to complete limited lifetime warranty on cdvigroup website.
INSTALLATION MANUAL
V1SR - V3S - V3SR - V3SRB - V4S - V4SR - V4SRB - V5S - V5SR - V5SRB
Surface mount Electromagnetic locks
10 cdvi.com
cdvigroup.com
Altri manuali per V1SR
4
Questo manuale è adatto per i seguenti modelli
9
Indice
Lingue:
Altri manuali CDVI Serratura

CDVI
CDVI V3E36R Manuale utente

CDVI
CDVI BO600EVO Manuale utente

CDVI
CDVI SHL1200 Manuale utente

CDVI
CDVI V1ER Manuale utente

CDVI
CDVI I180SR Manuale utente

CDVI
CDVI I180ER Manuale utente

CDVI
CDVI DWAA35 Guida utente

CDVI
CDVI GARH Manuale utente

CDVI
CDVI SM300 Manuale utente

CDVI
CDVI PROFIL100EINT Manuale utente