Celsius EVAP 2600 Manuale utente

USER GUIDE
EVAP 2600

WARNING—READ AND SAVE THE AIR COOLER GUIDE AND USER MANUAL
The Air Cooler Guide and User Manual are intended to provide important
information needed to set up, operate, maintain and troubleshoot your Air
Cooler. Failure to follow these instructions may damage and/or impair its
operation, create hazards, and void the warranty. In case there is any
inconsistency or conflict between the English version and any other language
version of the content of this material, the English version shall prevail.
When using electrical appliances, basic safety precautions should always be
followed
This appliance can be used by children aged from 8 years and above and
persons with reduced physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards
involved. Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
DO NOT operate with a damaged cord or plug. If the supply cord is damaged,
it must be replaced with a supply cord which is as per manufacturers
specifications, by the authorized service centre or its service agent or a
similarly qualified person in order to avoid a hazard.
Before operating the product, remove the packaging and check that product
is in good condition.
DO NOT allow children to play with this appliance, packaging or plastic bags.
Check the household voltage to ensure it matches the appliance’s rating
specifications.
DO NOT use an extension cord with this unit.
DO NOT run power cord under carpeting, or cover it with rugs or runners.
Keep the cord away from areas where it may be tripped over.
Always ensure the water tank is filled with water above the "min." level mark,
when operating the air cooler in evaporative COOLING mode.
Always unplug the Air Cooler before refilling the water tank, cleaning,
servicing or relocating the unit.
WARNINGS

Never pull the cord. Remove it from the electrical outlet/ socket by grasping
and pulling on the plug-end of the cord.
This appliance has been manufactured for use in domestic environments and
must not be used for other purposes.
DO NOT use in areas where gasoline, paint or other flammable goods and
objects are stored.
DO NOT operate the unit on COOL setting with an empty tank as this may
result in damage to the water pump.
DO NOT attempt to repair or adjust any electrical or mechanical functions of
the Air Cooler, as this may void the warranty.
DO NOT cover the cooler’s air inlet or outlet, as this may damage the motor.
DO NOT insert or allow objects to enter any ventilation or exhaust opening, as
this may damage the unit and may cause electrical shock or fire.
DO NOT operate with the Honeycomb Cooling Media removed, as this will
overload and damage the motor.
DO NOT leave the operating appliance unattended for an extended period of
time.
DO NOT operate this unit if it is damaged or malfunctions. Refer to the
Troubleshooting section.
If problem still exists contact the Customer Support Center.
Always place the unit on a dry level floor.
DO NOT use in bathrooms or near water. DO NOT keep the product where it
may fall into water or a water container.
Store in a dry area when not in use.
Always grip the side handles to move the Air Cooler.
WARNING: To reduce the risk of fire or electric shock, do not use this appliance
with any solid state speed control device.

WHAT IS EVAPORATIVE COOLING?
Honeywell Evaporative Air Coolers are built to maximize energy efficiency and
keep energy costs low. Warm air is drawn into the cooler and enters the
Honeycomb Cooling Media. Water pumped from the water tank pours over the
Honeycomb Cooling Media. As the warm air passes through the Honeycomb
Cooling Media, the water absorbs the heat, naturally cooling and humidifying the
air. A fan propels the cooled air out into the room. This no-compressor system
cools naturally, efficiently and inexpensively.
The recommended maximum relative humidity level is 60% or less, which allows a
noticeable temperature decrease. The temperature will be lower in drier climates
because higher evaporation occurs when the humidity is low.

TROUBLE SHOOTING
GUIDE


1) Control Panel
2) Lever for Horizontal Louvers
3) Louvers
4) Water Level Indicator
5) Water Fill Door
6) Handle
7) Side Grill
8) Casters
9) Rear Grill Screws
10) Rear Grill
11) Water Tank
12) Drain Plug
13) Water Inlet Valve
14) Power Cord & Plug

SPEED / ON - OFF
Connect to the power supply and turn the SPEED knob. The fan will
start. Change the speed from 3 to 1 (1 for Low, 2 for Medium and 3 for
High fan speed). To switch OFF the unit, turn the SPEED knob to 0.
COOL
You must add water before operating the unit on Cool mode. Turn the
COOL knob to the ON position to activate evaporative cooling. The
water pump will operate and you will feel the cooler air after the
Honeycomb Cooling Media is completely wet.
SWING
Turn the SWING knob to the ON position to activate the movement of
the louvers. The louvers will begin to move left to right automatically.
Vertical Air Flow - You can manually adjust the lever located at the
front of the unit to change vertical air flow.
CONTROL PANEL

It is ideal to use the Continuous Water Supply Connection to run the unit for long
periods of time without refilling the tank. This also helps prevent pump failure in
case the cooler is running with inadequate water in the tank.
CAUTION: Unplug the unit from the electrical power outlet before filling or
emptying the water tank. Continuous Water Supply Connection:
For a continuous water supply, you will need a garden hose that is connected to a
main water supply.
• Locate the male connector at one end of the garden hose. Insert the garden hose
connector into the water inlet valve of the cooler. Screw and tighten the water
inlet valve onto the threaded part of the garden hose connector, making sure the
hose connector is secured to ensure there will be no leaks. If there is leakage, the
hose and the water inlet valve may not be connected properly. Try to disconnect,
replace and tighten the water inlet valve again.
• When the connection is secured, turn ON the water supply and the water will
flow into the water tank of the cooler.
• The cooler is now set so the water refills automatically when the water tank is
empty, or when the water reaches below a minimum level.
• When the water tank is full, the water inlet valve will automatically.
• Please open the water valve for minimum flow as too
much pressure could damage the inlet pressure control system. WARNING: The
maximum water inlet pressure is 0.5 MPa.
FILLING WITH WATER

MANUAL WATER TANK REFILL
• Using a portable container or a garden hose, you can refill the water tank
manually by pouring water into the water tank through the water inlet hole
located at the top of the air cooler.
• Check the water level indicator to know when the water tank is full. Do not fill
water above the "Max." water level mark to avoid water droplets collecting on the
louvers.
NOTE
WARNING: Always ensure the water in the water tank is above the minimum (Min.)
water level mark for both Continuous & Manual Water Refill. Running the unit in
Cool mode with inadequate water may cause pump failure.
The water capacity refers to the total volume of water that can be contained
within the air cooler water tank and water distribution system. The water capacity
in the tank at the “Max.” indicator level may be lower than the actual water
capacity of the air cooler.
WARNING: Do not fill water tank with dirty water or salt water. This can damage
the unit and Honeycomb media.
In Cooling Mode, when water in the tank is below the minimum indicator level, the
air cooler water pump will automatically turn off. This helps to protect the water
pump from running without water in the tank. When the water pump is turned off,
the air coolers stops evaporative cooling.
To reactivate the water pump and restart the unit in Cooling Mode, first switch
OFF the unit and unplug from the power outlet. Fill the water tank with fresh water
above the minimum level mark. Plug in and switch the unit ON again.
Questo manuale è adatto per i seguenti modelli
4
Indice
Altri manuali Celsius Condizionatore d'aria