Centrix SA1DK Manuale utente

SA1DK
Instruction Manual

3
CONTENT
INTRODUCTION
TechnicalSpecications
KeyFeatures
INSTALLATION
MountingtheSA1DKController
WiringDiagrams
FEATURES AND CONCEPTS
Normal,Secure&MasterUsers
ModesofOperation
ChangingtheModelofOperation
RequestToExit(REX)Button
CaseandBackTamper
BL-D40ExternalSounder
PROGRAMMING THE SA1DK
EnteringProgrammingMode
ExitingProgrammingMode
1 ChangingtheOpenCode1
2 ChangingtheOpenCode2
3 ChangingtheProgrammingCode
4 ChangingtheNormal/SecureCode
5 ChangingtheNormal/BypassCode
DoorChimeSettings
6 SettingFailSafe/SecureOperation
SettingTamperSirenTime
7 EnrollingPrimaryandSecondaryCodes
8 DeletingPrimaryandSecondaryCodes
0 ReturntoFactoryDefaultSettings
ReplacingalostProgrammingCode
ReplacingalostNormal/SecureCode
APPENDIX
Glossary
...........................................................................................................................3
....................................................................................................4
.....................................................................................................................5
.............................................................................................................................6
........................................................................................6
...............................................................................................................8
...................................................................................................9
.......................................................................................9
........................................................................................................10
...................................................................................11
........................................................................................12
..................................................................................................12
..............................................................................................13
................................................................................................14
..........................................................................................15
.............................................................................................15
.............................................................................................16
............................................................................................16
..................................................................................17
.............................................................................18
.............................................................................18
..............................................................................20
.......................................................................21
.........................................................................24
..................................................................................26
..............................................................................................26
..........................................................................................27
...................................................................................................................................28
................................................................................................................................28
TheSA1DKisakeypadaccesscontrolunit.
Theunitacceptsupto500usersandprovidesentryviatheuseofPINcodes.
Equipmentprovided
ThefollowingisprovidedaspartofeverySA1DKpackage:
-SA1DKAccessControlUnit
-InstallationKit
-InstallationandOperatingInstructions
Additional Equipment Required
1) Electric Lock Strike Required
FailSafe(PowertoLock)orFailSecure(PowertoOpen)
2) Power Supply with Backup Battery
12to16VDC(FromaRegulatedPowerSupply)
3) Request To Exit (REX) Button
NormallyOpenType-Switchisclosedwhenpressed
4) BL-D40 External Sounder (Optional)
ProvidesSiren,Bell,andChimefunctionstoSA1DK
Introduction

45
Electrical Characteristics
Operating Voltage Range :
12to16VDC FromaRegulatedPowerSupply
Maximum Input Current :
Standby:20mA Notincludingattacheddevices
Max:60mA Notincludingattacheddevices
Relay Outputs :
LockStrikeRelay Electronic,3.5A
withbuiltinsuppressorprotection
Inputs :
REX N.O.,DryContact
LEDs
TwoTri-coloredLEDs
Environmental Characteristics
Operating Temperature : -25°Fto145°F(-31°Cto63°C)
Operating Humidity: 0to95%(Non-Condensing)
Mechanical Characteristics
Dimensions:
3.62“(92mm)Lx3.62:(92mm)Wx0.94”(24mm)D
Weight :
0.3lbs(130g)
Here are some of the SA1DK’s key features:
•BuiltinKeypadforPINcodeentry
•InternalBuzzer
•Comeswithsecurityscrewandsecurityscrewtool
•TwoStatus/ProgrammingInterfaceLED’s
•ThreeUserLevels
•(NormalUser,SecureUser,MasterUser)
•ThreeModesofOperation
•(NormalMode,BypassMode,SecureMode)
•“CodeSearch”featuremakesmaintainingusercodeseasier
•InputforRequesttoExit(REX)button
•LockStrikeElectronicRelaywithbuilt-insuppressorprotection
•Comeswithmountingtemplateforeasierinstallation
•BuiltinCaseandBackTamper
•Bell,Chime,SirenandStrobefeaturesavailablewithBL-D40
•Bell,Chime,Siren,BatteryBackup,TamperOutput(OpenCollector20mA)features
availablewithPS-X41(OutputPower1.2A)andPS-X42(OutputPower1.8A)
•ProgrammableSirenTime
•ProgrammableLockStrikeReleaseTime
•ComeswithSuppressionDiode(1N4004)
Technical Specication Key Features

6 7
Mounting the SA1DK Controller
1)Beforestarting,selectthelocationtomounttheSA1DKcontroller.Thislocationshouldbeat
shoulderheightandonthesamesideasthedoorhandle.
2)TheSA1DKisdesignedtobeeasilymountedtoaUSGangBox.RemovetheBezelScrew.
(UsethediagrambelowtohelpyoulocatetheBezelScrew)
3)ScrewthecontrollerontoaUSGangBoxthroughthetwoMountingHolesprovided.(See
diagramonthenextpagetohelpyoulocatetheUSGangBoxmountingholes)
4)Passthewiresthroughtheexit/entryholesandattachthemtothecontrollersterminalblocksas
showninthewiringdiagrams.(Wiringdiagramsforcommoninstallationscanbefoundonpages
9to11).
5)Replacethecontroller’sbezelandreplacethefactorydefaultscrewwiththesecurityscrewthat
isprovidedintheInstallationKit.AsecurityscrewtoolisalsoprovidedintheInstallationKit.
Installation
ModeLED DoorLED
3x4MatrixKeypad
TerminalBlocks
MountingHole MountingHole
BezelScrew
BellButton

8 9
Wiring Diagrams Normal, Secure & Master Users
SA1DK
SA1DK
BL-D40
Wiring the Lock Strike Relay and REX
Wiring the BL-D40 External Sounder
TheSA1DKacceptsupto500usersandprovidesentryviatheuseofPINcodes.Eachuseris
providedwithtwocodememoryslots,MemorySlot1(PrimaryCode)andMemorySlot2(Secondary
Code).
Thewayinwhichthetwomemoryslotsareprogrammeddeterminesausersaccesslevelandalso
determinesthewayinwhichtheSA1DKgrantsaccessinitsthreeModesofOperation.
There are three user levels:
Normal User
ANormalUseronlyhasaPrimaryCodeandisonlygrantedaccesswhentheSA1DK
isinNormalorBypassMode.
Secure User
ASecureUsermusthaveaPrimaryandSecondaryCodeprogrammed,thetwocodes
mustnotbethesame.TheSecureUsercangainaccesswhentheSA1DKisinanyof
itsthreeModesofOperation.InNormalModetheSecureUsermustusetheirPrimary
Codetogainentry.InSecureModetheSecureusermustpresentboththeirPrimary
andSecondaryCodesinordertogainentry.
Master User
AMasterUsermusthavebothPrimaryandSecondaryCodesprogrammedwiththe
samePINcode.TheMasterUsercangainaccessduringanyModeofOperationby
presentingtheirPINcodetothecontroller.(TheMasterUserisconvenientbutisless
securethanaSecureUser).

10 11
Changing the Modes of OperationModes of Operation
Changing from Normal Mode to Secure Mode :
ThedefaultfactorysettingfortheNormal/SecureCodeis3838
1)Enterthe4-digitNormal/SecureMode
•ModeLEDwillFlashred
2)Pressthe“#”keytoconrmtheModeChange
•ModeLEDisred
Changing from Secure Mode to Normal Mode :
ThedefaultfactorysettingfortheNormal/SecureCodeis3838
1)Enterthe4-digitNormal/SecureMode
•ModeLEDwillFlashgreen
2)Pressthe“#”keytoconrmtheModeChange
•ModeLEDisgreen
Changing from Normal Mode to Bypass Mode :
Seepage18tocreate/modifytheNormal/BypassCode
1)Enterthe4-digitNormal/BypassMode
•ModeLEDwillFlashorange
2)Pressthe“#”keytoconrmtheModeChange
•ModeLEDisgreen
Changing from Bypass Mode to Normal Mode :
Seepage18tocreate/modifytheNormal/BypassCode
1)Enterthe4-digitNormal/SecureMode
•ModeLEDwillFlashgreen
2)Pressthe“#”keytoconrmtheModeChange
•ModeLEDisgreen
The SA1DK has 3 Modes of Operation:
1) Normal Mode
•ModeLEDisgreen
NormalModeisthedefaultmode.InnormalModethedoorislockeduntilaPrimaryCode
ispresentedtothecontroller.Specialcodessuchas“OpenCode1”and“OpenCode2”
areactiveinNormalmode.(SeePage16formoreinformationonOpenCode1&Open
Code2).
2) Bypass Mode
•ModeLEDisorange
IsBypassMode,accesstothepremisesisdependentonwhetherthecontroller’sLock
StrikeRelayisprogrammedforFailSafeOperationonFailSecureOperation.
WhentheLockStrikeRelayisprogrammedforFailSecureOperation,thedoor
islockeduntiltheDoorBellButtonispressed.
WhentheLockStrikeRelayisprogrammedforFailSafeOperation,thedooris
constantlyunlocked.
3) Secure Mode
•ModeLEDisred
OnlySecureandMasterUserscanaccessthepremisesduringtheSecuredMode.
ASecureUsermustentertheirPrimaryandSecondaryCodestogainentry.
AfterenteringtheirPrimaryCodetheDoorLEDwillashgreenfor10seconds,
duringwhichtheSecondaryCodemustbeentered.
AMasterUseronlyneedstopresenttheirPINcodeoncetogainentry.

12 13
Request to Exit (REX) Button BL-D40 External Sounder
Case and Back Tamper
TheREXbuttonmustbelocatedinsidethepremisestobesecuredandisusedtoopenthedoor
withouttheuseofaproximitycardorPINcode,itisusuallylocatedinaconvenientlocation,e.g.
Insidethedoororatareceptionist’sdesk.ThefunctionoftheREXbuttondependsonwhetherthe
LockStrikeRelayisprogrammedforFailSafeOperationorFailSecureOperation.Thedoorchime
intheBL-D40doesnotsoundwhentheREXbuttonisusedtoopenthedoor.
1)FailSecureOperation:FromthemomenttheREXbuttonispressed,thedoorwillbeunlocked
untilthe“LockStrikeReleaseTime”haspassed.Afterthistime,thedoorwillbelockedevenifthe
REXbuttonhasnotbeenreleased.
2)FailSafeOperation:FromthemomenttheREXbuttonispressed,thedoorwillbeunlockeduntil
theREXbuttonisreleased,plusthe“LockStrikeReleaseTime”.Inthiscasethe“LockStrike
Relay”onlybeginsitscountdownoncetheREXbuttonhasbeenreleased.
TheBL-D40ExternalSounderiscompatiblewiththeAC-X31,AC-X32,AC-x41andAC-X42series
StandaloneControllers(Foramoreup-to-datelistofcompatibleproductschecktheRosslareWeb
Siteatwww.rosslare.com.hk).Itisdesignedtooperateindoorsandinstalledwithinthepremisesto
besecured.TheSoundercanbepoweredby16VDCor12to24VDCpowersupply.
TheBL-D40iscapableofemittingfourdifferenttypesofalertsbothaudibleandvisual;Bell,Door
Chime,SirenandStrobeLight.
1)TheBellalwayssoundswhenthecontroller’sdoorbellbuttonispressed.
2)TheDoorChimecanbeprogrammedtosoundwheneverthecontrollerunlocksthedoor(the
DoorChimedoesnotsoundwhentheREXbuttonisusedtoopenthedoor).
3)TheSirencanbeprogrammedtosoundwhenthecaseofthecontrollerisopenedorwhenthe
controllerisremovedfromthewall.ThecontrollercanalsoprogramthelengthoftheSireninthe
BL-D40.
TheControllercommunicateswiththeBL-D40usingacodedproprietaryRosslarecommunications
protocol. This provides a more secure link between the Controller and the BL-D40. If the BL-D40
receives any unrecognized codes on its communication line or communication between the
controllerandtheBL-D40aresevered,theStrobewithashrepeatedlyuntilthecommunication
problemhasbeenresolved.
Ifthecaseofthecontrollerisopenedorthecontrollerisremovedfromthewall,atampereventis
triggeredandacodedtampersignalissenttoaBL-D40,PS-X41SeriesorPS-x42SeriesPower
Supply,orothercompatibledevice.
IftheBL-D40ExternalSounder,PS-X41SeriesorPS-X42SeriesPowerSuppliesreceiveaTamper
EventSignal,theywillactivateaSirenandifavailableaStrobeLight.TheSirentimecanbeeasily
programmedintheSA1DKfrom0to9minutes.
ClearingatampereventisdonebyenteringavaliduserorOpenCodethatwillopentheLockStrike
OutputinthecurrentModeofOperation.Forexample,whileinSecureMode,usingtheOpenCode
tocleartampereventwillnotworkbecausetheOpenCodedoesnotworkisSecureMode.However,
applyingaMasterCodeorSecureCodewillclearthetampereventinSecureMode.

14 15
Programming the SA1DK Entering Programming Mode
Exiting Programming Mode
Programming Menu
ProgrammingtheSA1DKisdonesolelyviatheunit’skeypaddrivenProgrammingMenuSystem.
ToreachtheProgrammingMenuSystemtheSA1DKmustrstbeplacedintoProgrammingMode.
See“EnteringProgrammingMode”onPage15formoreinformation.
DuringtheSA1DK’smanufacturingprocesscertaincodesandsettingsarepre-programmed.These
settingsarethecalledthe“DefaultFactorySettings”.
ThetablebelowshowsthenamesofalltheSA1DKMenus.ItalsoshowsofalltheSA1DK’sdefault
factorycodesandsettings.
1)Pressthe“#”keyfor2seconds
•ModeLEDwillturnoff
•DoorLEDwillturnred
2)Enteryour4-digitProgrammingCode
IftheProgrammingCodeisvalidthedoorLEDwillturngreenandtheSA1DKwillbein
ProgrammingMode.
Note: -TheSA1DKmustbeinNormaModetoentertheProgrammingMode
-ThefactorydefaultProgrammingCodeis1234
-IfaProgrammingCodeisnotenteredwithin5seconds,theSA1DKwillreturntoNormal
Mode
1)ToexittheProgrammingModeatanytime:
Pressthe“#”keyfor2seconds.
•Youwillhear3beeps
•TheDoorLEDwillbeoff
•TheModeLEDwillturngreen
ThisindicatesthattheSA1DKhasreturnedtoNormalMode.
2)WrongentriesmayresetthecontrollerbacktoNormalMode.
3)WhileinProgrammingModeifnokeyispressedfor1minutetheSA1DKwillexitprogramming
modeandreturntoNormalMode.
4)AShortpresson“#”keymayalsoreturnthesystemtoNormalModeincertainProgramming
Modes.
You will ndcomplete description andinstructions for each ofthe above menuitems on the
followingpages.
Factory
Settings
Menu Description
2580
0852
1234
3838
N/A
0004
ChangeOpenCode1
ChangeOpenCode2
ChangeProgramCode
ChangeNormal/SecureCode
ChangeNormal/BypassCode
ChangeDoorRelease Time
EnrollPINCode
DeletePINCode
ReturntoDefaultFactorySetting
1
2
3
4
5
6
7
8
0
Menu Number

16 17
Changing the Open Code 1
Changing the Open Code 2
Changing the Programming Code
TheOpenCode1ismainlyusedasamethodtoquicklytesttheLockStrikeRelayduringinstallation.
The Default factory Setting for the Open Code 1 is 2580. When the rst user is added to the
controller,thedefaultOpenCodewillautomaticallybedeleted,readyforanewOpenCode1to
bere-entered.
1)EnterProgrammingMode
2)Press“1”toenterMenu 1
•TheModeLEDwillturnred
3)Enterthenew4-digitcodeyouwishtosetasOpenCode1
4)SystemreturnstoNormalMode
•Youwillhear3beeps
•TheDoorLEDwillturnoff
•TheModeLEDwillturngreen
Note: -OpenCode1doesnotfunctioninSecureMode.
-WrongentrieswillreturnthecontrollertoNormalMode.
-Code0000willeraseanddeactivatetheOpenCode.
1)EnterProgrammingMode
2)Press“2”toenterMenu 2
•TheModeLEDwillturnorange
3)Enterthenew4-digitcodeyouwishtosetasOpenCode2
4)SystemreturnstoNormalMode
•Youwillhear3beeps
•TheDoorLEDwillturnoff
•TheModeLEDwillturngreen
Note: -OpenCode2doesnotfunctioninSecureMode.
-WrongentrieswillreturnthecontrollertoNormalMode.
-Code0000willeraseanddeactivatetheOpenCode.
1)EnterProgrammingMode
2)Press“3”toenterMenu 3
•TheModeLEDwillturngreen
3)Enterthenew4-digitcodeyouwishtosetasProgrammingCode
4)SystemreturnstoNormalMode
•Youwillhear3beeps
•TheDoorLEDwillturnoff
•TheModeLEDwillturngreen
Note: -ProgrammingCodecannotbeerased,i.e.thecode0000isnotvalidandwillnoterase
theProgrammingCode.
TheOpenCode2ismainlyusedasamethodtoquicklytesttheLockStrikeRelayduringinstallation.
TheDefaultFactorySettingfortheOpenCode2is0852.Whentherstuserisaddedtothecontroller,
thedefaultOpenCodewillautomaticallybedeleted,readyforanewOpenCode2tobere-entered.

18 19
Changing the Normal / Secure Code
Changing the Normal / Bypass Code and
Door Chime Settings
1)EnterProgrammingMode
2)Press“4”toenterMenu 4
•TheModeLEDwillashred
3)Enterthenew4-digitcodeyouwishtosetasNormal/SecureCode
4)SystemreturnstoNormalMode
•Youwillhear3beeps
•TheDoorLEDwillturnoff
•TheModeLEDwillturngreen
TheNormal/BypassCodeisalsousedtoturntheDoorChimeoffandon.
1)EnterProgrammingMode
2)Press“5”toenterMenu 5
•TheModeLEDwillashorange
3)BelowisalistofthefourdifferentwaysthattheNormal/BypassCodeandDoorChimecan
beprogrammed.
a)DisableBypassMode-DisableDoorChime
b)DisableBypassMode-EnableDoorChime
c)EnableBypassMode-DisableDoorChime
d)EnableBypassMode-EnableDoorChime
a) Disable Bypass Code - Disable Door Chime
Enterthe4-digitcode0000
b) Disable Bypass Code - Enable Door Chime
Enterthe4-digitcode0001
c) Enable Bypass Code - Disable Door Chime
Enterany4-digitcodeendingwith0
d) Enable Bypass Code - Enable Door Chime
Enterany4-digitnotendingwith0
4)SystemreturnstoNormalMode
•Youwillhear3beeps
•TheDoorLEDwillturnoff
•TheModeLEDwillturngreen
Note: -TheDoorisonlygeneratedwhentheLockStrikeRelayisactivatedduetoavalidcode
entry.
Indice