WARRANTY
All electronic controls are warranted to be free of defects in manufactur-
ing, material and workmanship for a period of one year from the date of
purchase by the owner/end-user.
Limitations
This warranty does not apply to the bathtub and/or spa but solely to the
components manufactured by CG AIR SYSTÈMES INC.
This warranty shall not apply to the following incorrect operating proce-
dures, breakage or damages caused by fault, abuse, misuse, careless-
ness, misapplication, alteration, modification, improper maintenance of
the unit, as well as an act of God, fire, chemical or natural corrosion or
any other casualty.
The owner of the product covered by the present warranty is entirely
responsible for the proper installation of the product in accordance with
the installation manual provided. CG AIR SYSTÈMES INC. neither installs
nor supervises nor contracts for the installation and consequently cannot
be held responsible for the installation.
CG AIR SYSTÈMES INC. is not responsible for any damages or claims result-
ing from defects that could have been discovered, repaired or avoided
by inspection and testing prior to installation.
CG AIR SYSTÈMES INC. makes no express warranty, no warranty for mer-
chantability, no warranty of fitness for particular purposes, neither any other
warranty implied or statutory for its products other than specified above.
In no event shall CG AIR SYSTÈMES INC.’s liability exceed the purchase
price of the defective part.
If any such product proves to be defective within the warranty period,
CG AIR SYSTÈMES INC. reserves the right to repair or replace the defec-
tive product with one of equal value.
Commercial limitations
In addition to the above conditions and limitations, if the product is to be
used as a display, the warranty period begins when the product has
been placed on display. Under no circumstances will CG AIR SYSTÈMES
INC. be responsible for any profit loss due to a malfunction of the unit. This
warranty gives the owner/end-user specific legal rights and the
owner/end-user may have other rights which vary from one
state/province to another.
CG AIR SYSTÈMES INC. reserves the right to discontinue and/or change
models, colors and specifications in design together with replacement
parts without notice and without incurring any obligations.
TROUBLESHOOTING
Always switch off power before servicing.
The electronic control fails to operate:
1. Verify electric power supply. Reset circuit or replace fuse if necessary.
2. Verify all electrical connections (including keypad connection).
3. Verify that the Ground Fault Circuit Interrupter (G.F.C.I.) has not
tripped.
4. If the system has been functioning for quite some time, it is possible that
the thermal protection has shut off the motor. It is programmed to
switch off the system and to wait for at least 30 minutes before using it
again. Verify that air is flowing through all jets. If not, cover the jets with
warm water, then switch system ON and OFF several times. The air out-
lets should be cleared. If this is not sufficient, carefully knock on the jet
heads with the handle of a screw driver or a similar plastic tool while
the blower is running.
5. If you have added a keypad extension, make sure that it has been cer-
tified by the manufacturer of the electronic control. It could be the
cause of your problem.
The blower or pump never stops:
1. Verify that the blower is well connected to the control box.
2. Verify the keypad connection.
3. Verify that there is no water reaching the electrical components under
your bathtub.
The pump starts but stops after about 1 second:
1. Verify the keypad connection.
2. The water level sensor does not detect water in the bathtub. Water
must reach at least 2 inches (5cm) above the highest jet, add water
and restart. If there is sufficient water, the water level detectors may
not be installed properly.
3. Contact your dealer for further troubleshooting.