1.2 Technical Data
Hot water
Input ........................................... 28.90 kW 98612 Btu/h
Output.. ...................................... 23.00 kW 78480 Btu/h
Water flow raised
45 “C (81 OF).............................. 7.4 Ymin 1.7 gaI/min
Water flow raised
35 OC(63 OF).............................. 9.5 Ymin 2.1 gaifmin
Water ffow raised
30 ‘C (54 OF).
............................. 11.1 Ymin 2.5 gallmin
Maximum temperature.. ............. 50 OC 140 OF
Maximum pressure.. ................... 10 bar 150 psi
Minimum working pressure.. ...... .6 bar 9 psi
Gas rate.. .................................... 2.743 m%-r 96.87
ft3fh
Burner pressure.. ........................ 11.8 mbar 4.7 in wg
Central heating
Maximum input.. ........................ 27.64 kW 94313 Btulh
Maximum output.. ...................... 22.00 kW 75068 Btu/h
Gas rate (maximum). .................. 2.63’m3/h 92.98 f&h
Burner pressure.. ........................ 11.2 mbar 4.5 in wg
Minimum input.. ........ ................. 10.85 kW 37020 Btu/h
Minimum output.. ....................... 7.64 kW 26062 Btu/h
Gas rate (miniium) ................... 1.Om?h 35.31
ft3lh
Burner pressure.. ........................ 1.5 mbar 0.6 in wg
Minimum flow rate ..................... 3OOK-l 1.1 gai/min
Maximum pressure.. ................... 2.5 bar 36.5 psi
Natural gas
Manifold injectors 14 of.. ............ 1.28 mm 0.05 in
Pilot injector.. .............................. 0.3 mm 0.01 in
Gas section restrictors 2/3 valves 4.4 mm 0.17in
l/3 valve.. 2.3 mm 0.09 in
Connections
Gas.. ............................................................ 22 mm copper
Heating flow ................................................ 22 mm copper
Heating return. ............................................. 22 mm copper
Mains cold water inlet ..............._.................. 15 mm copper
Hot water outlet ._........................... .............. 15 mm copper
Electricai supply 240 V - 50 Hz, fused at 3A.
Electrical consumption ................................. 195 watts
Internally fused, two at 2A (BS 4265)
Weight ......................................................... 42 kg 92.4 lb
Water capacity ............................................. 4 litres 7 pints
Ignition - Anstoss continuous spark generator
Electrode - Chaffoteaux et Maury Ltd, spark gap 5 mm
Boiler thermostat - EGO (82’C)
Boiler limit thermostat - SOPAC /JAEGER (85X)
Hot
water
fim?t thermostat - SOPAC /JAEGER (57°C + 3°C)
Safety overheat thermostat (Tokoswitch - (lOSaC)
(Eimwood - (105°C)
Gas valve - AEMF
Fan motor - SEL.
Pressure switch - DUNGS 102 Pa / 55 Pa
Pump head - GRUNDFOS UP 15160
C.H. expansion vessel initial charge piessore - 0.65 bar (9.6 psi)
Domestic expansion vessel initii charge pn?ssure - 2 bar (30 psi)
1.3 Minimum Clearances around Boiler
Top above air duct .. ... 50 mm (2 in)
Bottom below case. ____._._. 150mm (6in)
Sides . . . . . 100mm (4ir-l)
Front. . 6GOmm(24in)
I
1.4 Wall Thicknesses
The standard flue assembly can accomodate the foliowing thicknesses.
Rear : from 55 mm to 576 mm
Side : from 55 mm to 392 mm
(this allows for a minimum clearance of 100 mm between the appliance and the side waii. As this dimension
increases. so the maximum side wail thickness available decreases).
Extension flue assemblies are available to accomodate wali thicknesses of:
Rear : from 577 mm to 2876 mm
Side : from 393 mm to 2692 mm
See figs. 2 and 3 for details of number of extensions required.
IMPORTANT NOTE : The extension ducts supplied, up to a maximum of 3, wili in fact permit a greater length than
indicated to be covered. The ducts MUST be cut so that the maximum length from the centre line of the flue turret to
the outermost point of the air duct DOES NOT EXCEED 3 metres horizontal. Greater length must not be used.
See sections 1.4.1. 1.4.2. 1.4.3.
3