Challenger SLFLO460B Manuale utente

High Lumen LED Floodlights
460w, 600w
Models: SLFLO460B, SLFLO600B
SLFLO460B
SLFLO600B
Installation Manual

Introduction
Thank you for purchasing your Challenger high lumen led floodlight,
these instructions should be read carefully and retained for further
reference and maintenance.
IMPORTANT
•Installation must be carried out by a skilled electrician who is
familiar with the appropriate standards and technical
requirements of the appliance also taking in to consideration
the latest building regulations.
•The person carrying out the installation is to check and verify
that the total load on the circuit, including the rating of the
cable, fuse and/or circuit breaker is not exceeded.
•nsure there is adequate ventilation around the luminaire
•nsure the AC mains supply is isolated when installing or
servicing.
•This product must be earthed.
•Once illuminated DO NOT look or stare at the L D fitting
directly when in close proximity.
•Never modify the luminaire, there are no user serviceable parts
inside.
•The luminaire has a selectable wattage output (600W model
only). Please ensure that the correct wattage out ut has been
selected as this will have an impact on the lighting design to
ensure the correct light levels are achieved.

S ecification
•High lumen output L D floodlights
•Slimline lightweight design
•Polycarbonate encapsulated lens module
•Lumiled 5050 L D chip
•Pre-wired cable – 1m
•90° x 120° beam angle
•5000k Colour temperature
•IP65 ingress protection
•IK09 impact protection
•50,000 hours rated life
•Input voltage – 100-277V AC 50/60Hz
•Power factor - PF≥0.9
•CRI rating - >70
•Operating temperature -40°~+40°c
•5-year warranty
•Selectable wattage on the SLFLO600B
Model Lumens
Wattage
Dimensions
(mm)
In ut
Current
Weight
SLFLO460B
65996 460w 340x647x115
5.6A 11.88kg
SLFLO600B
81229
71936
60014
46343
600w
500w
400w
300w
651x323x136
8A 15.94kg

Installation
•nsure the electrical AC power is switched OFF before and
during installation
•For the AC supply cable and connections, a cable that is rated
to 90°C should be used
•nsure the luminaire is securely fixed to a surface/ceiling free
from vibration
•When adjusting the angle of the fitting please ensure that there
is enough slack in the cable so the range of movement of the
luminaire is unhindered
•A suitable IP rated junction box is required for the premade AC
electrical connections (Brown = Live, Blue = Neutral and
Yellow/Green = arth). This luminaire must be earthed
•Check the lighting fixture is firmly fixed and the Allen bolts have
been inserted in to the bracket
•Ensure that the correct wattage out ut has been selected
(600W model only) as this will have an impact on the lighting
design to ensure the correct light levels are achieved.
•Check all the connections are wired and terminated correctly

Refer to the following diagram when you install the fixture:
SLFLO460B:
SLFLO600B:

1. Turn off the AC Supply
2. Fix the luminaire bracket to the
surface.
3. Keep enough slack in cable to
ensure when adjusting the
angle, the movement is
unhindered
4. Connections- AC-Live: Brown, AC-Neutral: Blue, GND arth:
Yellow-Green.
5. Ensure that the correct wattage out ut has been selected
(600W model only) as this will have an impact on the lighting
design to ensure the correct light levels are achieved.
6. Check the circuit and connections are correct prior turning on
the AC supply
Adjust the wattage via di switch
( lease remove the screw on ca and re lace)
Ensure that the correct wattage out ut
has been selected (600W model only) as
this will have an impact on the lighting
design to ensure the correct light levels
are achieved.
SLFLO600B
Please Note: The cable must be
connected either through a waterproof
connector or junction box. The
waterproof connector or junction box is
not supplied and will need to purchase
separately.

Maintenance
Repairs should only be carried out by a suitably qualified person.
Regular cleaning of luminaires should be carried out at regular
intervals not only to ensure good optical performance but also ensure
that dirt does not accumulate to such an extent as to impair the
electrical or thermal safety of the fitting. This should be done with the
luminaire switched off/isolated and a soft damp cloth should be used,
do not use any chemicals or abrasives.
Light Source Maintenance
The light source of this luminaire is not replaceable; in case the light
source needs to be replaced (e.g. at the end of its life), the whole
luminaire shall be replaced.
Warranty
This product is covered by an extended warranty for 5 years from date
of purchase.
The extended warranty is available for installations in the UK or Ireland
by a competent person in accordance with the current building and I
wiring regulations.
If the defective product is no longer available, then Challenger may
provide alternatives of similar specification and quality.
The ambient temperatures and environment and voltage range
according to manufacturer specifications are not exceeded
The product is not exposed to any adverse mechanical stresses or
impact
For full terms and conditions in regard to our extended warranty
please refer to the website.

Follow us for all the latest news and product information
CHALLENGER SECURITY PRODUCTS
10 Sandersons Way,
Blackpool, FY4 4NB
mail: e[email protected]
Web: www.challenger.co.uk
Due to our policy of continuous improvement we reserve the right to change specification
without prior notice. rrors and omissions excepted. These instructions have been carefully
checked prior to publication. However, no responsibility can be accepted by Challenger for any
misinterpretation of these instructions.
Challenger_SLFLO460B_SLFLO600B_Instructions_Rev01
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Challenger Proiettore