Chemyx OEM 30050 Manuale utente

OEM
USER MANUAL
INTELLECTUAL PROPERTY
All Intellectual Properties, as dened below, owned by or which is otherwise the property of Chemyx Inc. or its suppliers relating to the Chemyx syringe pumps, including but not limited to, accessories,
parts or software relating thereto (Chemyx Syringe Pumps), are proprietary to federal and state laws, and international treaty provisions. Intellectual Property includes but is not limited to, inventions
(patentable or unpatentable), patents, trade secrets, copyrights, software, rmware, computer programs, and related documentation and other works of authorship. Moreover, you agree that you will
not, and will not attempt to, modify, prepare derivative works of, reverse engineer, disassemble the Chemyx syringe pumps, decompile or otherwise attempt to create source code from the related
software/rmware. No title to or ownership in Intellectual Property is transferred to you. All applicable rights of the Intellectual Property shall remain with Chemyx and its suppliers.

2
EU Declaration of Conformity (DoC) 3
Safety Information 7
Product Overview 5
Product Drawings 6
Data Sheet 8
Loading a Syringe 9
Pump Control by Computer 10
Conytroller Programs 11
Commands 12
Pump Maintenance 13
Syringe Pump Accessories 14
Warranty and Repair Information 15
Appendix A: Syringe Volume/Diameter Reference Table 16
Table of Contents

3
EU Declaration of Conformity (DoC)
We:
Declare that the DoC is issued under the sole responsibility of the manufacture and belongs to
the following product(s):
All Syringe Pump Model Names, including:
- Fusion 100
- Fusion 200
- Fusion 4000
- Fusion 6000
- Nexus 3000
- Nexus 6000
- NanoJet StereoTaxic
- Fusion 100T
- OEM
The object of the declaration described above is in conformity with the relevant Union harmo-
nization legislation:
The technical documentation required to demonstrate that the products meet the
requirements of the LV and EMC directives has been compiled and is available for
inspection by the relevant enforcement authorities.
Signature on behalf of manufacturer:
Authority:
Date:
Chemyx, Inc.
10905 Cash Road
Stafford, TX 77005
(281) 277-5499
sales@chemyx.com
- EN 613326-1: 2013 Electrical Components for measurement, control, and
laboratory use - EMC requirements - Part 1: General Requirements
- EN 61010-1: 2010 European Low Voltage Directive 2014/35/EU Safety
requirements for electrical equipment for measurement, control, and
laboratory use Part 1: General Requirements
- Directive 2011/65/EU of the European Parliament and of the Council of 8 June
2011 on the restriction of the use of certain hazardous substances in electrical
and electronic equipment.
Attention!
The attention of the specifier, purchaser, installer, or user is drawn to special measures and limitations to use which
must be observed when these products are taken into service to maintain compliance with the above directives.
Details of these special measures and limitations to use are available on request,
and are also contained in the product manuals.
Jeff Wu, Senior Engineer, Chemyx, Inc.
Date: March 1, 2018
Declaration of Conformity

4
Safety Information
Please read the following safety precautions to ensure personal safety and operational longevity of the Chemyx syringe pump.
Chemyx is not responsible for the equipment if used in a manner not specied by the manufacturer; warranty coverage
provided by the equipment may be dropped as a result.
CHEMYX PRODUCTS ARE NOT APPROVED FOR CLINICAL USE ON HUMANS.
Chemyx is not responsible for the use of power supplies outside the stated electrical specications or failure to switch the
power converter from 220V to 110 V while in the 220V environment or vice versa.
The product should be properly grounded.
Use Proper Power Supply
Ground Product
Warranty coverage will be lost if the pump is opened without authorization from Chemyx. Do not touch any electrical
connectors on or in the product.
Even though the pump can operate at extremely fast speeds, the user must determine the proper ow rate for any given
application. For instances, pumping at 90 mL/min using a 20-gauge needle will cause stalls and/or potential bursting of the
syringe. Chemyx is not responsible for any damage that might result from situations similar to the example above.
Do Not Open The Pump
Do Not Operate With Suspected Failures
Do not place ngers between the pusher block and the end block while the pump is running.
Read all labels on the product to ensure proper usage.
The user is responsible for wetting ground glass syringes and setting and tightening the safety collar/bar appropriately.
Pinch Hazard
Observe all Warning labels on Product
Chemyx is not Responsible for Syringe Damage

5
Product Overview
The Chemyx OEM syringe pump is a bolt-on microuidic pump designed for integration into analytical instruments requiring
precision ow functionality with a removable syringe. OEM series syringe pumps are capable of delivering microliter accurate
ows from a wide range of syringe sizes. This OEM module system is ideal for a multitude of applications like an injection into a
mass spectrometer, microuidics, and diagnostic instrument integration.
OEM - Model 30050 OEM Full Case Module - Model 30060

6
OEM Drawings - Model 30050
Product Drawings

7
OEM Drawings - Full Case Model 30060
Product Drawings

8
!"#$%&"'%&( ( (((((((((((((((((!"#$%&'($)$*"+$,-./$)$+"#$01%%$-'23/4$$566"6$)$77$)$8"9$2:;$
)$"*+,( ( ((((((((((((((((((((((((((((((((((((9$%<4
-$*./0,'-1(2'#3/"0%2$((((((((((((((((( =>?$@==?$>AB?$C&DE
6*$F=
Model SKE 50 - Data Sheet
!"#$%&"'%&( ( (((((((((((((((((!"#$%&'($)$*"+$,-./$)$+"#$01%%$-'23/4$$566"6$)$77$)$8"9$2:;$
)$"*+,( ( ((((((((((((((((((((((((((((((((((((9$%<4
-$*./0,'-1(2'#3/"0%2$((((((((((((((((( =>?$@==?$>AB?$C&DE
24 DC
WEIGHT 5 lbs
REGULATORY COMPLIANCE CE, FCC, ETL, RoHS
DIMENSIONS 8.7 long x 4.3 wide x 3.7 tall inches (22.2 x 11 x 9.5 cm)
OEM - Model 30050 OEM Full Case Module - Model 30060
OEM Modules
Data Sheet
0.0001ul/min (with 0.5ul syringe)
140mL/min (with 50mL syringe)

9
The OEM can accommodate one syringe. The volume of the syringes can vary from a minimum of 0.5 μL up to a maximum of 60
mL. Syringes of any material (e.g., glass, plastic, stainless steel, etc.) can be used; however, some use cases may require syringes
that are more accurate and durable.
1. If necessary, move and tighten the infusion safety collar
(see Adjusting the Safety Collar).
2. While pressing in the lock-release button, slide the pusher
block all the way to the left.
3. Pull up on the spring-loaded syringe clamp and place
the syringe in one of the channels of the syringe-holder
block. Ensure that the ange of the syringe barrel is ush
against the edge of the syringe-holder block. Slowly lower
the syringe clamp to secure the syringe in place.
231
4. Press the lock-release button and slide the pusher block
to the right until it is ush against the syringe plunger.
The Fusion OEM pump moter can generate up to a maximum of 30 lbs. Some syringes made of more fragile materials may not
be able to withstand the full linear force of the pump.
Loading a Syringe
Motor Power
OEM

10
The OEM syringe pumps can be controlled with an external computer using an RS232 serial connection.
Two types of connections are available for external computer control: DB9 and USB, cables for each are available for purchase
through Chemyx (call 1-281-277-5499 or visit www.chemyx.com/contact-us).
Most computer operating systems (e.g., Windows, macOS, Linux, etc.) have built-in terminal programs that can be used to
type in the commands that run the pump. On Windows XP and earlier, HyperTerminal can be used to control to the pump. On
macOS and Linux, the screen command in Terminal can also be used to control the pump. There are also numerous third-party
programs for serial connections that exist for each operating system that may be easier to use and provide more features. A
third-party program will be necessary to connect with computers running Windows Vista and later.
For tips on operating the built-in terminal programs and information on available third-party programs, please visit www.
chemyx.com/support.
For the DB9 serial connection, a Male-to-Female DB9 cable must be used. Do not use any “null modem,” “crossover”, or “crossed-
over” cables. The cable can be of any length up to 50 ft; however, the speed of the connection is often detrimentally aected
at lengths over 15 ft.
For a USB serial connection, a USB-A to USB-B cable should be used. The maximum possible length of a single USB cable is 15 ft;
however, USB cables should be less than 10 ft for optimum performance. Multiple USB cables can be chained together to make
a longer connection as long as the hub connecting each individual cable is connected to a power supply.
A USB-to-DB9 serial adapter can be used to connect a DB9 serial connection to the USB port on a computer.
All of these connections require the proper drivers to be installed on the computer. Typically, most current operating systems
already contain drivers for the USB serial connection. They may also already have drivers for the DB9 serial connection. USB-to-
DB9 adapters typically need to have a USB-to-serial driver installed. For more information on downloading and installing drivers
please visit www.chemyx.com/support.
DB9 Serial Cable (Male-to-Female)
Cable Requirements
Connecting
TTL Connection
USB-A to USB-B cable
Pump Control by Computer
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Chemyx Pompa dell'acqua
Manuali Pompa dell'acqua popolari di altre marche

Sykes AmeriPumps
Sykes AmeriPumps GP100M Guida alla risoluzione dei problemi

DUROMAX
DUROMAX XP WX Series Manuale utente

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 Manuale utente

Franklin Electric
Franklin Electric IPS Manuale utente

Xylem
Xylem e-1532 Series Manuale utente

Milton Roy
Milton Roy PRIMEROYAL Manuale utente