Troubleshooting
This troubleshooting section lists common problems and their solutions. If a troubleshooting procedure directs
you to replace a module of the node, see Removing and Replacing Modules.
•OIB, on page 1
•Troubleshooting the node, on page 2
OIB
There are 3 LEDs on the OIB, Heartbeat LED, Communication LED, and Power LED.
Communication
LED
Heartbeat LEDPower
LED
Condition
Normal behaviorSteady blinkSteady blinkOnNormal
Check power supply and power supply
voltages. Check cabling and that the
appropriate power shunts are installed in the
launch amplifier.
OffOffOffPower supply
fault
If Heartbeat LED and Communication LED
blink on power up and then stay off, problem
is with boot. Can be a device failure or
software is not loaded. Try cycling power.
Not blinkNot blinkOnError #1
OS is ok but node control software is not
running or is stuck. If this condition persists
for more than a minute or two after power
up, check all the cables connecting the lid
and launch amplifier. Try cycling power.
Not blinkSteady blinkOnError #2
This condition should not be possible unless
Heartbeat LED is damaged.
Steady blinkNot blinkOnError #3
Troubleshooting
1