Clearfield FieldSmart Splice Only Manuale utente

FieldSmart®Fiber Distribution Point (FDP)
Splice Only Pedestal
Installation Manual ____________________________________________________
Manual 020017 REV A - Oct 2018

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
2
FieldSmart®Fiber Distribution Point (FDP)
Splice Only Pedestal
Installation Manual ______________________________________________________
Manual 020017 REV A - Oct 2018
Table of Contents
Application 3
Description 3
Technical Specications 3
Components 4
Pedestal Access 6
Cable Preparation & Installation 7
Grounding 9
Fiber Splicing 9
Closing the Pedestal 12
Standard Warranty 13
Proprietary Notice 14
Technical Support 14

3
FieldSmart®Fiber Distribution Point (FDP)
Splice Only Pedestal
________________________________________________________Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
Manual 020017 REV A - Oct 2018
Application
Description
The FieldSmart FDP Splice Only Pedestal provides splice or interconnect connectivity at
the access point for the last mile drop. The FieldSmart FDP Splice Only Pedestal
incorporates eld-tested slack management and ber splice trays to provide a craft-
friendly splice only access solution. The splice only pedestal can be congured to support
the specic drop cable, multi-ber and ring cut requirements. The Cleareld® designed
back plane makes it possible for the bulkheads to integrate into industry standard
pedestals.
Technical Specications
The FieldSmart FDP Pedestal is a value added version of an Emerson BD5 distribution
pedestal. This style pedestal is a round-cornered, square-design telephone distribution
pedestal accepted for use by the RDUP (formerly RUS). The pedestal has been modied
to accommodate the use of ber optic distribution and drop splices.
This pedestal is designed to accommodate outside plant cables with a loose tube/buffer
tube construction. It can handle both armored and non-armored cables. If cables are to
be installed in a ring cut/mid-span opening conguration, then only cables capable of
passing the RDUP mid-span criteria of the PE-91 specication are allowed.
Included in this pedestal are: a splice tray bracket, one splice tray, a dielectric wrap
around shield, radius limiting spools, Velcro style cable management, cable securing zip
ties and a shield isolation bonding/grounding bracket assembly.
FieldSmart Splice
Only Pedestal Metallic Emerson BD5 Non-metallic ProFORM 12 Non-metallic Pencell
10 x 10
Dimension 43.25” H x 10.5” W x 10.5” D 45” H x 10.5” W x 14.5” D 31.4” H x 13” W x 13” D
Cover Height 31.25” 30” 20”
Base Height (Buried) 12” 15” 11.4”
Material Galvanized steel High performance thermo-plastic HDPE/LDPE
Density Up to 384 splices Up to 144 Splices
Number of Splice Trays Up to 16 Up to 6
Splice Capacity 24 splices in each splice tray
Splice Tray Dimensions 10 mm H x 163 mm W x 126 mm D

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
4
FieldSmart®Fiber Distribution Point (FDP)
Splice Only Pedestal
Installation Manual ______________________________________________________
Manual 020017 REV A - Oct 2018
2
3
7
1
4
5
6
8
1. Radius limiting spool
2. Velcro cable management
3. Splice tray
4. Secondary splice tray holder mounting location
5. Distribution and drop cables
6. Vinyl dust /UV shield
7. Zip Tie cable management
8. Security screw
9. Grounding/Bonding Plate
10. Outside cover
10
9
Metallic Emerson BD5
Components

5
FieldSmart®Fiber Distribution Point (FDP)
Splice Only Pedestal
________________________________________________________Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
Manual 020017 REV A - Oct 2018
Non-metallic Pencell 10 x 10
1. Radius limiting spool
2. Velcro cable management
3. Splice tray
4. Outside cover
5. Security screw
1
2
34
5

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
6
FieldSmart®Fiber Distribution Point (FDP)
Splice Only Pedestal
Installation Manual ______________________________________________________
Manual 020017 REV A - Oct 2018
The interior of the pedestal can be accessed by loosening the security screw on the right hand side of the pedestal
using a 7/16” thin wall socket or a telecommunications industry “can wrench”.
Then, by supporting the top of the cover and pulling out and up on the handle, the outer cover of the pedestal can be
removed to provide access to the interior.
Pedestal Access
1.
2.
Metallic Emerson BD5
Non-metallic Pencell 10 x 10
The interior of the pedestal can be accessed by
turning the security screw on the pedestal using a 7/16”
thin wall socket or a telecommunications industry “can
wrench”.
The cover can then be lifted away.
1.
2.

7
FieldSmart®Fiber Distribution Point (FDP)
Splice Only Pedestal
________________________________________________________Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
Manual 020017 REV A - Oct 2018
Ring cut/Mid-span opening
OSP distribution cables that are entering or exiting the pedestal can be prepped in either a ring cut/mid-span opening fash-
ion or at the end of the cable.
End of the cable
Cable Preparation & Installation
3M 2172
The pedestal is designed to hold more than 20 feet of buffer tube from a 144 OSP cable, but most manufacturers recom-
mend not exposing more than 20 feet in an OSP environment. This rule is especially true for ring cut applications (see
RDUP PE91).
In either cable prep method, please verify with your cable manufacturer to see if a central strength member clamp (3M 2172
or equivalent) must be installed to secure the central strength member, in order to maintain the cable warranty.
Cable clamp installed

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
8
FieldSmart®Fiber Distribution Point (FDP)
Splice Only Pedestal
Installation Manual ______________________________________________________
Manual 020017 REV A - Oct 2018
If a shielded cable is to be used and grounded in this application,
then a bonding clamp (3M 4460-D or equivalent) shall be attached
in addition to the strength member clamp.
3M 4460-D Bonding clamp installed
Cables to be installed can be secured to the
back plane of the pedestal using the zip tie
mounts found at the bottom of the pedestal.
When attaching the cables to the back plate using zip ties, it is very important to
not fully tighten the zip ties around the cable. Each zip tie should allow at least
1/8” of clearance on all sides. This is important as the cable will need to piston
or freely move inside the zip tie independently from the pedestal in the case of
pedestal shifting. Be sure to leave at least 4 - 6 inches of cable from the zip tie
to the strength member tie-off.
Note: A drop cable is also installed in this picture.
The excess buffer tube should then be routed loosely around the radius limiters
provided and then secured loosely with the Velcro management that is installed
in the pedestal.
Zip tie locations

9
FieldSmart®Fiber Distribution Point (FDP)
Splice Only Pedestal
________________________________________________________Installation Manual
Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
Manual 020017 REV A - Oct 2018
Each pedestal comes with a pre-installed grounding and bonding plate.
Grounding
Fiber Splicing
The pedestal is capable of holding up to 144 splices by adding up to eleven 12 ber trays (part number 004834), one
at a time to the included bracket.
Note: If more than 6 trays are used, you will not be able to hinge the entire stack to access lower splices. Although the
bracket will accomodate12 trays, Cleareld recommends only using 6 trays for 72 splices. Trays can be added by sliding the
new tray onto the hinge pins and then folding it down to snap the tray in place.
1.

Direct: 763.476.6866 • National: 800.422.2537 • www.SeeCleareld.com • [email protected]
10
FieldSmart®Fiber Distribution Point (FDP)
Splice Only Pedestal
Installation Manual ______________________________________________________
Manual 020017 REV A - Oct 2018
Align the pins and insert into position Fold the tray down and snap in place
Additional capacity (up to 12 more trays) can be added to the pedestal by adding a second splice tray bracket (part
number 005622) to the back wall.
2.