www.colorato.net
USAGE AND MAINTENANCE MANUAL
FOR A SOLID FUEL STOVE
1. Technical specification:
MODEL BULK DIMENSION NET
WEIGHT
THERMAL
POWER
OUTER
DIAMETER OF
SMOKE PIPE
CLWS-O8G 465 x 390 x 790 mm 54 kg 7-8 kW 120 mm
CLWS-08GO 465 x 390 x 990 mm 57 kg 7-8 kW 120 mm
CLWS-07G 330 x 360 x 930 mm 39 kg 5-7 kW 120 mm
CLWS-12OV 500 x 450 x 1030 mm 98 kg 10-12 kW 120 mm
CLWS-09SSD 450 x 490 x 930 mm 55 kg 8-9 kW 120 mm
CLWS-09CSD 450 x 490 x 930 mm 66 kg 8-9 Kw 120 mm
CLWS-09CRS 450 x 490 x 930 mm 64 kg 8-9 kW 120 mm
CLWS-09CRC 450 x 490 x 930 mm 75 kg 8-9 kW 120 mm
2. Installation:
- the stove must not be placed near wooden or plastic furniture parts, nor near cooling
devices. Minimum distance between the stove and such elements must be 30 cm.
- if the stove is placed on the floor made from combustible materials (wood, itison, floor
plastic, etc.) it is necessary to protect the floor with metal sheet 10 cm width from the sides
of the stove, and 50 cm from the front side of the stove.
- the stove should be attached to a chimney with inner diameter of at least 120 mm and
height of 6 m. If multiple stoves are attached to a single chimney, the attachment distance
should be at least 2 m.
3. Usage:
- the stove uses wood, wood briquettes or a coal with less calories (brown coal, lignite…) as
a fuel
- the heating strength depends on the type and quality of fuel used
- the initial heating of the stove should be gradual to avoid sudden stresses on the material.
Do not use the stove with capacity during the first 8-10 hours (1-2 days) of firing.
- Thermoresistant color on the stove will be fully formed after the first firing of the stove
- make sure that the air regulator (located on the front side of the stove) and stack valve
regulator (located at the chimney spout) are fully opened when starting a fire
- the combustion intensity is regulated with the air regulator located at the front of the stove
by turning it left-right, and with stack valve regulator located at the chimney spout by
rotating it