Comelit HUB32LCD Istruzioni operative e di manutenzione

EN
TECHNICAL
MANUAL
Quick installation manual for wireless intruder alarm
control panel HUB32LCD Passion.Technology.Design.

2
Index
Index ................................................................................................. 2
Available documentation ................................................................ 3
System overview ............................................................................. 3
System technical specifications .............................................................4
Product range .................................................................................. 5
Package Contents ........................................................................... 5
Description of the control panel .................................................... 6
Installing the control panel............................................................. 6
Removing the backplate..........................................................................6
Installing the LAN module .......................................................................7
Installing the 2G/3G module....................................................................7
Replacing the backplate..........................................................................7
Choosing the correct mounting position...............................................8
Connecting/replacing the battery...........................................................8
Installing the wall mounting backplates ................................................9
Installing the desk base...........................................................................9
The front panel............................................................................... 10
Switching on for the first time...................................................... 10
Installation Wizard......................................................................... 11
Set GSM/3G ............................................................................................11
Connect to Wi-Fi? ..................................................................................11
Connect to LAN? ....................................................................................11
Set date/time? ........................................................................................11
Set entry/exit times?..............................................................................11
Set RF zones?.........................................................................................12
Add RF sirens? .......................................................................................12
Add users?..............................................................................................12
Set phonebook? .....................................................................................12
Connect to APP? ....................................................................................13
Service............................................................................................ 14
Accessing the Installer menu................................................................14
Activating the installation wizard .........................................................14
Perform a walk test (zone test).............................................................14
RSSI test .................................................................................................14
Search for a device ................................................................................14
Consult event log ...................................................................................15

3
System overview
Comelit art. HUB32LCD is a wireless intruder alarm control panel for use in residential applications and in small- and medium-
sized commercial applications. It has a 16 x 2-character display and a Capsense keypad which allows rapid navigation of the
installer and user menus.
A fundamental advantage of art. HUB32LCD lies in its easy installation and programming: a built-in installation wizard allows
quick system startup, even without using a PC. The programming tools include Windows-based software with configuration
level selection and an integrated text menu.
Featuring native support for Internet and cloud connection via built-in WiFi and LAN, art. HUB32LCD uses cloud-based
communication for configuration and remote use, without requiring port forwarding on the router.
Communication between the control panel and the wireless devices takes place by means of a secure and encrypted two-way
protocol which makes it possible to constantly monitor message transmission eciency.
In addition to the built-in keypad and the two-way remote controls, users can fully manage art. HUB32LCD using Comelit app,
the application for mobile devices (iOS and Android platforms) which also utilises all the system video verification functions if
IP cameras are installed in the network. Up to four HD IP cameras can be recorded continuously to capture CCTV relating to
events, including 10 seconds of pre-event recording. Live streaming of cameras is also available on the app (MAX 16 cameras).
Thanks to the built-in loudspeaker and microphone, art. HUB32LCD oers two-way audio communication for personal use
or audio verification of alarms using the 2G or 3G module. For greater usability, voice messages can be enabled for the main
system procedures.
A full set of event signalling channels is provided to satisfy all requirements, including push notifications with video verification,
e-mail and IP-based digital protocols for alarm receipt control panels. When a 2G or 3G GSM module is installed, SMS, voice
calls and digital audio protocols are also available.
A wide range of wireless devices is available to satisfy all installation requirements. Refer to the pages below for details of
available products.
Available documentation
• Quick installation manual: This document contains all the information required for product installation and initial startup.
• HUB32LCD installation and programming manual: this document contains all the information required to program a Secur
HUB system via keypad.
• Secur HUB Manager programming manual: this document contains all the information required to program a Secur HUB
system using Secur HUB Manager software.
• HUB32LCD user manual: this document contains all the information required by the end user of a Secur HUB system.
• The documentation is available online, at mycomelit.com
The SECUR HUB system comes with a series of technical manuals containing detailed information for the installation,
programming and use of the control panel and the available accessories.

4
System technical specifications
HUB32LCD
Radio functions
Wireless technology Two-way - BeaconPlus
Frequency band 868 MHz
Max. radio transmission range in an open area 1500 m
Max. number of wireless zones 32
Wireless outputs 32
Max. number of RF remotes 32
Sensor supervision Yes, adjustable
System technical
specifications
User codes 32
Installer codes 2
Arming mode Full, Partial 1, Partial 2
Video verification Yes
Time programs 16
Arming programs 16
Macro 10
Hardware technical
specifications
Number of wired outputs 2
Number of wired zones 2 (balancing NO, NC, single, double. Balancing resistor 1K8)
Indoor siren Built-in speaker (2 WATTS)
Keypad technology Capsense
Display 16 x 2-character LCD
Tamper Built-in lever switch
SD card slot Yes, micro-SD (MAX. 32 GB)
CCTV technical
specifications
IP camera recording 4 cameras @ 5fps, 384 kbps, HD
Live cameras 16 (viewing via Comelit app)
Communications
GSM/GPRS channel 2G or 3G module
SIM card Micro-SIM (not included)
TCP-IP channel Built-in
WiFi Built-in
“Access point” function Yes
Programming ports USB, LAN, WIFI
Signalling protocols Voice, SMS, e-mail, CID, SIA, SIAIP, CID IP, SIA SMS, CID SMS, APP
Two-way audio Yes
Voice menu Yes
Audio module Built-in
Customisable audio events Yes
Voice guide Yes
Applications / Software
User APP Yes, iOS/Android
Desktop Secur HUB manager
Built-in installation wizard Yes
Electrical specifications
Power supply 90-240 Vac 50/60 Hz
Consumption 7W
Number of built-in auxiliary power outputs 1
Auxiliary power supply characteristics 13.8 V / 50 mA
Wired output characteristics Open collector, 12 V, 100 mA
Built-in battery Yes (3.6 V, 4250 mAh)
General
Dimensions (L x H x P) 150 x 230 x 31
Weight 632 g
Support backplates Wall mounting (built-in terminal block), desk base (optional)
Additional backplate for side cable input Yes
IK protection rating IK06
Operating temperature -10°C to +40°C

5
Product range
Comelit code Description
HUB32LCD 32-ZONE RADIO CONTROL PANEL, LCD INTERFACE, IP (Wi-Fi & LAN)
HUB2G 2G MODULE FOR HUB RADIO CONTROL PANEL
HUB3G 3G MODULE FOR HUB RADIO CONTROL PANEL
RF4KEY 4-BUTTON REMOTE CONTROL
RFPA RADIO PANIC BUTTON
RF1MCW MAGNETIC CONTACT WITH 1 WIRELESS INPUT, WHITE
RF1MCB MAGNETIC CONTACT WITH 1 WIRELESS INPUT, BROWN
RF2MCW MAGNETIC CONTACT WITH 2 WIRELESS INPUTS, WHITE
RF2MCB MAGNETIC CONTACT WITH 2 WIRELESS INPUTS, BROWN
RF12PIR WIRELESS VOLUMETRIC SENSOR, 12 M
RFSMK RADIO SMOKE DETECTOR, SERIES 2
RFH2O RADIO FLOODING SENSOR, SERIES 2
RFSIR702 OUTDOOR RADIO SIREN, SERIES 2
HUBDESK DESK BASE FOR HUB CONTROL PANELS
BRK004 WALL/CEILING BACKPLATE FOR WIRELESS PIR SENSOR
Package Contents
• Control panel with battery and wall mounting backplate
• Additional backplate with side cable routing
• Ethernet and I/O interface
• Stick-on cover for Ethernet and I/O interface
• Quick installation manual
• Quick-start guide manual

6
Description of the control panel
2
3
14
5
8
7
6
10 11
9
1. LCD/CAP-SENSE front panel
2. Microphone
3. Micro USB connectors
4. Battery
5. Battery connector
6. Loudspeaker
7. 2G/3G module connector
8. Tamper switch
9. RJ45 Ethernet connector
10. Wired I/O terminal block
11. A/C supply terminal block
Installing the control panel
Removing the backplate
21

7
Installing the LAN module
21
Installing the 2G/3G module
Replacing the backplate
21
3
21

8
Choosing the correct mounting position
Connecting/replacing the battery
When choosing the correct mounting position for the control panel, take the following factors into account.
Functional factors:
• When the control panel is on and running, a wireless network is generated: avoid fitting the control panel near sources of
RF electromagnetic disturbance, such as large electrical appliances or air conditioners.
• The control panel should be located in a central position in relation to the wireless peripherals (sensors, sirens).
• Avoid positioning the control panel near large metal objects or surfaces.
• Radio frequency transmission is adversely aected by metal-based building materials; consider the option of minimising
this type of obstruction.
• Depending on the communication channels you intend to use, the control panel should be fitted so as to oer good GSM
or WiFi signal strength.
• You will need to consider the availability of electricity mains and Ethernet connections.
Safety factors:
• The control panel should be fitted so that access while it is armed activates at least one detection zone.
• Install the control panel in a place that cannot be seen from outside the monitored areas.
• Keep it out of reach of children, to avoid unforeseen and unintentional operation.
Usability factors
• The control panel should be mounted at a height between 1.2 m and 1.8 m.
• Avoid installing the control panel behind doors or other obstacles which could cause delays in using it.
Once the battery has been replaced, the control panel should be reconnected to the backplate immediately so that it can start
up using the main power supply and not just the battery.
Observe local regulations for correct battery disposal.

9
Installing the wall mounting backplates
Installing the desk base
21 3
2A1A 3A
21 3
54 6

10
Switching on for the first time
The first time it is switched on, the control panel will ask you to select a language.
Use the Down/Up arrow on the navigation keypad to select the language you want and confirm by pressing Return.
The front panel
1
2
34
56 7
1. 16 x 2-character LCD.
2. LED indicators: green, orange, red.
3. Alphanumeric keypad.
4. Arming/disarming buttons.
5. Back/Cancel/Delete button.
6. Enter/Confirm button.
7. Navigation keypad / menu button.
• Green LED: indicates the system is armed (lit steadily) or in “not ready to arm” condition (flashing). The LED is o if the
system is ready for arming.
• Orange LED: indicates a fault (lit steadily) or isolated / bypassed zones (flashing).
• Red LED: indicates an alarm / tampering in progress (lit steadily) or an alarm in the memory (flashing).
Altri manuali per HUB32LCD
2
Indice
Altri manuali Comelit Pannello di controllo