Comet System Web Sensor T5540 Manuale utente

COMET SYSTEM
www.cometsystem.cz
Web Sensor T5540
Web Sensor T5541
Web Sensor T6540
Web Sensor T6541
USER GUIDE

IE-SNC-T5(6)5xx-04
2
©Copyright: COMET System, s.r.o.
Is prohibited to copy and make any changes in this manual, without explicit agreement of
company COMET System, s.r.o. All rights reserved.
COMET System, s.r.o. makes constant development and improvement of all its products.
Manufacturer reserves the right to make technical changes without previous notice.
Misprints reserved.
Manufacturer is not responsible for damages caused by using the device in conflict with
this manual. To damages caused by using the device in conflict with this manual can not be
provided free repairs during the warranty period.
This user manual describes devices with firmware version 1-5-5-x. For devices with older
firmware versions 1-5-2-x and 1-5-3-x please read manual IE-SNC-T5(6)5xx-03.

IE-SNC-T5(6)5xx-04
3
Table of contents
Introduction........................................................................................................................................................4
General safety rules .....................................................................................................................................5
Device description and important notices...............................................................................................5
Getting started....................................................................................................................................................7
What is needed for operation ....................................................................................................................7
Mounting the device....................................................................................................................................7
Device settings .............................................................................................................................................8
Checking functions....................................................................................................................................10
Device setup .....................................................................................................................................................11
Setup using web interface.........................................................................................................................11
Setup using TSensor software .................................................................................................................18
Factory defaults..........................................................................................................................................19
Communication protocols .............................................................................................................................21
Website........................................................................................................................................................21
SMTP –sending e-mails...........................................................................................................................21
SNMP ..........................................................................................................................................................22
Modbus TCP ..............................................................................................................................................23
SOAP...........................................................................................................................................................24
Syslog...........................................................................................................................................................26
SNTP ...........................................................................................................................................................26
Troubleshooting...............................................................................................................................................27
I forgot the device IP address..................................................................................................................27
I can not connect to the device...............................................................................................................27
I forgot the password for setup...............................................................................................................28
Factory defaults..........................................................................................................................................28
Display is off...............................................................................................................................................28
Device error states.....................................................................................................................................29
Technical specifications..................................................................................................................................30
Dimensions.................................................................................................................................................30
General parameters....................................................................................................................................31
Measured values.........................................................................................................................................33
Temperature measurement ......................................................................................................................33
Relative humidity measurement ..............................................................................................................33
CO2concentration measurement............................................................................................................34
Computed quantities .................................................................................................................................34
Operating terms .........................................................................................................................................36
End of operation .......................................................................................................................................37
Technical support and service .................................................................................................................37
Preventive maintenance............................................................................................................................37
Optional accessories........................................................................................................................................38

IE-SNC-T5(6)5xx-04
4
Introduction
This chapter provides basic information about device. Before starting please read
this manual carefully.
The Web Sensor devices are designed for measurement of temperature, relative humidity
and carbon dioxide concentration of air without aggressive substances. Measured quantities
are according device type. Devices with relative humidity measurement can show one of
computed quantities: dew point temperature, absolute humidity, mixing ratio and specific
enthalpy. Temperature units are °C or °F. Communication interface of Web Sensors is
Ethernet. Device types:
Type
Temperature
Relative humidity
CO2concentration
Computed quantity
T5540
T5541
T6540
T6541
Models marked TxxxxZ are custom-specified devices. Description of these devices is not
included in this manual.
CO2concentration measurement is based on Non-Dispersive Infrared Technology
(NDIR). CO2measurement is maintenance free due to the patented auto-calibration
feature. Auto-calibration compensates effects of aging the CO2 sensor and therefore is
guaranteed outstanding long-term stability. If the device is in operation permanently, an
auto-calibration will start each 24 operating hours.
Measured values can be read in „SLOW mode“ (filtered, averaged) or in „FAST mode“
(current values without averaging). „SLOW mode“ has advantages in applications like
climate control because of filtering short time peaks. As an example exhaled air from an
employee passing the sensor could affect the climate control negatively with a short
response time because the control would trigger a change of the ventilation based on this
one-time measurement. On the contrary in „FAST mode“ no software filter is used for
calculating the output value. This fact adds a noise of typ. ±30ppm which has to be
considered in terms of accuracy. Of principle measurement is the measured value of CO2
concentration depends on the value of air pressure - altitude at the installation site. For this
reason, it is suitable for accurate measurement to set the altitude of the installation site.
After power up of the device starts internal test. During this time (about 20s) LCD display
shows (----) instead of CO2concentration value. Web pages show n/a.
Chapter
1

IE-SNC-T5(6)5xx-04
5
General safety rules
The following summary is used to reduce the risk of injury or damage the device.
To prevent injury, please follow instructions.
The device can be services only by a qualified person. The device contains no
serviceable parts inside.
Don’t use the device, if it doesn’t work correctly. If you think, that the device is
not working correctly, let check it by qualified service person.
It’s forbidden to use the device without the cover. Inside the device can be a dangerous
voltage and may be risk of electric shock.
Use only the appropriate power supply adapter according to manufacturer specifications
and approved according to relevant standards. Make sure, that the adapter does not have
damaged cables or covers.
Connect the device only to network parts approved according to relevant standards.
Connect and disconnect the device properly. Don’t connect or disconnect Ethernet cable,
if the device is powered.
The device may be installed only in prescribed areas. Never expose the device to higher or
lower temperatures than is allowed. The device has not improved resistance to moisture.
Protect it from dripping or splashing water and do not use at areas with condensation.
Devices are not designed for locations with chemically aggressive environment.
Temperature and humidity sensors must not be exposed to direct contact with water or
other liquids. It is not allowed to remove the sensor cover to avoid any mechanical damage
of the sensors.
Don’t use device in explosive environments.
Don’t stress the device mechanically.
Device description and important notices
This chapter contains informations about basic features. Also there are
important notices concerning to functional safety.
Measured values can be displayed on LCD display or can be read using an Ethernet
connection. The visual indication of CO2concentration is provided by three-color LED.
The following formats are supported:
Web pages with user changeable look and XML files
Modbus TCP protocol
SNMPv1 protocol
SOAP protocol
The device can also be used to check measured values and if the limit is exceeded, device
sends warning messages. Possible ways to sending warning messages:

IE-SNC-T5(6)5xx-04
6
Sending e-mails up to 3 e-mail addresses
Sending SNMP traps up to 3 configurable IP addresses
Displaying the alarm status on web page
Sending messages to Syslog server
The device setup can be made by the TSensor software or web interface. TSensor software
can be free downloaded from the manufacturer’s website. Also you will find there latest
firmware for your device. Do not upload to your device firmware which is not designed for
it. Unsupported firmware can damage your device.
Device does not support powering over Ethernet cable (PoE). PoE splitter must be used.
Compatible PoE splitter can be purchased as optional accessories. Splitter must have 12V
output with approximately 1W.
Reliability of warning messages delivering (e-mail, trap, syslog), depends on
actual availability of necessary network services. The device should not be used
for critical applications, where malfunction could cause to injury or loss of
human life. For highly reliable systems, redundancy is essential. For more
information please see standard IEC 61508.
Never connect the device directly to the Internet. If it is necessary connect the
device to the Internet, properly configured firewall must be used. Firewall can
be partially replaced by the NAT.

IE-SNC-T5(6)5xx-04
7
Getting started
Here you can find informations necessary to put newly purchased equipment to
operation. This procedure is only informative.
What is needed for operation
To install the unit you need to the following equipment. Before installation check if it’s
available.
Web Sensor Tx5xx device
power supply adapter 9 - 30V/200mA
RJ45 LAN connection with appropriate cable
free IP address in your network
Mounting the device
check if the equipments from previous chapter are available
install the latest version of TSensor software. This software is used to all
device settings.
TSensor software can be free downloaded from the manufacturer’s website.
Software can be also supplied on CD. Device configuration can be made
using web interface. For web configuration is not TSesnor software necessary.
contact your network administrator to obtain following informations for the
connection to the network:
IP address:
_____._____._____._____
Default gateway:
_____._____._____._____
DNS serer IP:
_____._____._____._____
Subnet mask:
_____._____._____._____
check if there is no IP address conflict when you connect the device into
network for the first time. The device has from factory set the IP address to
Chapter
2

IE-SNC-T5(6)5xx-04
8
192.168.1.213. This address must be changed according to informations from
the previous point. When you installing several new devices, connect them to
the network one after another.
connect the Ethernet connector
connect the power adapter 9 - 30V (e.g. 12V/200mA)
LEDs on LAN connector should blink after connecting the power and LCD
start showing measured values.
Device settings
run configuration software TSensor on your PC
switch to an Ethernet communication interface
press button Find device...

IE-SNC-T5(6)5xx-04
9
the window shows all available devices on your network
click to Change IP to set new address according to network administrator
instructions. If your device is not listed, then click Help! My device wasn’t
found! Then follow the instructions. MAC address is on product label. The
device is factory set to IP 192.168.1.213.
gateway may not be entered if you want to use the device only in local
network. If you set the same IP address which is already used, the device will
not work correctly and there will be collisions on the network. If the device
detects a collision of IP address then reboot is performed automatically.
after changing IP address device is restarted and new IP address is assigned.
Restart of the device takes about 10 seconds.
connect to device using TSensor software and check the measured values. Set
the other parameters (alarm limits, SMTP server, etc.). Settings are saved after
click on button Save changes.

IE-SNC-T5(6)5xx-04
10
Checking functions
The last step is to check measured values on the device website. In the address bar of the
web browser, enter the device IP address. If the default IP address was not changed, then
insert http://192.168.1.213.
Displayed web page lists actual measured values. If the web pages are disabled, you can see
text Access denied. In the case of measurement error a text Error is shown instead value.