comfortel CINDERALLA Manuale utente

These instructions show how to install and maintain your comfortel product.
Specic adjustments vary according to each model.
www.comfortel.com.au
OWNERS GUIDE
PEDICURE SPA
CINDERALLA

2
www.comfortel.com.au
CINDERALLA
Dimensions:
W: 75cm L: 140cm
Code: 6715
WELS RATING
THIS MANUAL IS FOR:
The Cinderella is one of the latest additions to our exclusive range of pedicure spas. Featuring Shiatsu massage,
manicure armrests, adjustable footrest and full electric seat and back adjustment.

3
www.comfortel.com.au
CONTENTS
NOTE
PURCHASE DATE ..............................................................................................
INVOICE NUMBER ...........................................................................................
WARRANTY PERIOD BY PRODUCT...................................................4
SAFETY PRECAUTIONS......................................................................5
POSITIONING
POSITIONING...................................................................................6
PEDICURE SPA - INSTALLATION........................................................7
PEDICURE SPA - CONFIGURATION..................................................8
OPERATING THE PEDICURE SPA.......................................................9
OPERATION - MASSAGE AND SEAT ADJUSTMENT ..........................10
EXTRACTION PUMP - OPTIONAL .....................................................11
CLEANING AND MAINTENANCE
CLEANING AND MAINTENANCE ....................................................12

4
www.comfortel.com.au
WARRANTY PERIOD BY PRODUCT
NOTICE
The information contained in this document is subject to change without notice and should not be construed as a commitment by
Comfortel Furniture Pty Ltd.
Comfortel Furniture Pty Ltd. assumes no responsibility for any errors that may appear in this document nor does it make expressed or
implied warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and
tness for a particular purpose.
Comfortel Furniture Pty Ltd. shall not be liable for incidental or consequential damages in connection with or arising out of the use of
this document and the program material.
PERIOD AND DESCRIPTION PRODUCTS
12 MONTHS PARTS AND LABOUR All products
2 YEARS PARTS ONLY All products excluding small electrical appliances
3 YEARS PARTS ONLY All electric actuators
5 YEARS PARTS ONLY Taps cartridge, Ceramic basins
10 YEARS PARTS ONLY Taps – all parts excluding the cartridge Gas-lis and gas-li swivel plates
TERMS AND CONDITIONS
SEE WARRANTY CARD FOR MORE DETAILS ON TERMS AND CONDITIONS.
For more information about our warranty, see our warranty card, which is available from Comfortel or contact us at
www.comfortel.com.au.
All rights are reserved. No part of this document may be photocopied, reproduced or
translated to another language without prior written consent of Comfortel Furniture Pty Ltd.

5
www.comfortel.com.au
SAFETY PRECAUTIONS
LISTED BELOW ARE ESSENTIAL SAFETY PRECAUTIONS:
GENERAL SAFETY
1. Read carefully and keep these instructions in a safe place.
2. Use this product only for its intended function and do not use
attachments not recommended by the manufacturer.
3. Do not use outdoors.
ELECTRICAL APPLIANCES
4. All GPO’s must be installed by a qualied Electrician in
accordance with Australian standards.
5. DO NOT allow children to operate the electric motors in
this product.
6. Turn the power o and remove the plug when not in use.
7. Turn the power o and remove the plug when cleaning
the chair cushions.
8. Do not let the power cord get damaged in any way.
9. Keep the power cord away from heat sources.
10. Do not use an extension cord unless the cord complies with
Australia/New Zealand electrical safety standards.
11. Periodically inspect the power cord for signs of damage.
12. Do not operate any electrical item with a damaged
power cord.
PLUMBING
13. This unit must be plumbed by a licensed plumber.
IMPORTANT
DO NOT ALLOW CHILDREN AROUND THE
PEDICURE SPA WHEN IN USE
CONTRAINDICATIONS
CLIENTS WITH ANY INFECTIOUS SKIN OR NAIL CONDITIONS, OR
ANY OTHER PEDICURE CONTRAINDICATIONS.
CLIENTS WHO SUFFER FROM SERIOUS NECK OR BACK PROBLEMS
MAY BE CONTRAINDICATED TO THE
SHIATSU MASSAGE.
PREGNANT CLIENTS SHOULD NOT USE MASSAGE FUNCTIONS
CAUTION
NEVER USE ANY OF THE PLUMBING FITTINGS TAPS, DIVERTER ETC
OR THE FOOTREST TO LIFT THE PEDICURE SPA.

www.comfortel.com.au
6
POSITIONING
CONNECTION
1. Connect waste pipe (Installed) to 32/40mm waste outlet.
2. Connect hot and cold (½”connection) to respective hot
and cold supplies.
ELECTRICAL REqUIREMENTS
2 x 10 amp GPO required
MASSAGE: 240V, 50/60Hz, 1.0A
PUMP: INPUT 240V, 50/60Hz 0.25A
CAUTION
EXCESS TWISTING/MOVEMENT OF THE WASTE PIPE CAN CAUSE
LEAKING AT THE CONNECTION WITH THE PLUG & WASTE.
POSITIONING
DIAGRAM A DIAGRAM B
• Allow 470mm of space behind your Spa to provide room for recline of back rest.
PLUMBING AND WASTE
Follow diagram above for plumbing specications. All plumbing
must be installed by a licensed plumber in accordance with
local regulations.
REAR DRAIN
Exit water from rear. If water can not drain by gravity in compliance
of plumbing regulations, an extraction pump is required.
Cinderalla Spa Side View Cinderalla Spa Above View
01 01
02
03
04
1400mm
1400mm 750mm
470mm
470mm
HOT COLD
850mm
WALL
1/2” male hot & cold inlets
Mixer tap
32/40mm waste pipe
Drain
Whirlpool pump
01
02
03
04
05
ø75mm
P TRAP
01
03
04
02
CAUTION
NEVER USE ANY OF THE PLUMBING
FITTINGS TAPS, DIVERTER ETC OR
THE FOOTREST TO LIFT THE PEDICURE SPA.
WALL
05

www.comfortel.com.au
7
PEDICURE SPA - INSTALLATION
PLUMBING AND WASTE
• Allow for the necessary room around the unit for free movement.
DIAGRAM C DIAGRAM D
SPA ASSEMBLY
1. Mixer tap
2. Spa On/O
3. Adjustable foot-rest
4. Hand held shower
5. Water inlet spout
6. Pipeless Water Jet
7. Drain open/close
8. Drain plug
9. Diverter - hand held
shower/water inlet
Foot bath
03
05
08
06
04
01
09
02
03
07
05

8
www.comfortel.com.au
PEDICURE SPA - CONFIGURATION
DIAGRAM H
From rear of spa

9
www.comfortel.com.au
OPERATING THE PEDICURE SPA
CAUTION
ALWAYS CHECK WATER TEMPERATURE BEFORE USE;
HOT WATER CAN BURN SKIN. WATER TEMPERATURE
SHOULD NOT EXCEED 41° C 105° F.
03
05
08
06
04
01
09
02
03
07
05
OPERATING THE PEDICURE SPA
1. Turn the drain open/close counter clockwise to close drain.
2. Using the diverter, select the hand held shower or water
inlet spout.
3. Using the mixer tap to add water to the basin, continue to
add water until the ll line is reached or water massage jets
are fully covered.
4. Start or stop the massage water jets by pressing the spa on/
o button.
ADDING WATER
5. Turn the drain open/close counter-clockwise to close drain.
6. Using the diverter select the hand held shower or water
inlet spout.
7. Using the mixer tap to add water to the basin. Continue to
add water until the ll line is reached or pipeless water Jet
are fully covered.
8. Start or stop the massage water jets by pressing the spa on/
o button.
REMOVE WATER FROM THE PEDICURE FOOT BATH
9. Ensure the water massage jets are turned o by pressing the
spa on/o button.
10. Open the drain by turning the drain open/close in a
clockwise direction until it stops.
PEDICURE ASSEMBLY COMPONENTS
1. Mixer tap
2. Spa On/O
3. Adjustable foot-rest
4. Hand held shower
5. Water inlet spout
6. Pipeless Water Jet
7. Drain open/close
8. Drain plug
9. Diverter - hand held
shower/water inlet
DIAGRAM I
Foot bath
DIAGRAM J

10
www.comfortel.com.au
OPERATION
- MASSAGE AND SEAT ADJUSTMENT
OPERATING THE MASSAGE/ SEAT ADJUSTMENT
1. On/O button
2. Back rest - up
3. Back rest - down
4. Chair forward
5. Chair back
6. Rolling massage On/O - anti-clockwise (Light)
7. Rolling massage On/O - anti-clockwise (Medium)
8. Rolling massage On/O - anti-clockwise (High)
9. Rolling massage On/O - clockwise (Light)
10. Rolling massage On/O - clockwise (Medium)
11. Rolling massage On/O - clockwise (High)
4 5
2 3
1
118
107
96
DIAGRAM K
TIP
REMEMBER TO TURN MASSAGE OFF WHEN
CLIENT LEAVES THE CHAIR
Indice