Working conditions:
o o
temperature: -20 C ~ +50 C
RH:≤95%
Current and voltage requirements:
DC input: +12V - +24V
AC input: ~ 12V - 24V
standby current: ≤80mA
working current: ≤110mA
Applicable card mode:
EM ID card(Default)
T5557/T5567 card(Setting required)
Effective distance: 5cm
Capacity:
ZONE 1: up to 1000 passwords & card holders
ZONE 2: up to 10 passwords OR card holders
1. With internal EM reader.
2. Frequency: 125KHz.
3. Effective distance: 5cm.
4. ZONE 1: up to 1000 passwords & card holders.
ZONE 2: up to 10 passwords OR card holders.
5. Card access, code access and combined access.
6. Digital keypad operation.
7. Built-in pickproof function.
8. Watchdog timer, powerful reboot and self-recovery watchdog can connect with
the external unlock button.
9. Dual relay outputs.
10. Unlock output delay time: 0~99s.
11. IP rating: 65.
12. Dimension: 120*76*22mm.
13. Dual relay outputs for door opening, door status detecting, open door by button.
The function of door status detecting is for ZONE 1 only.
DH16A-10DT
DH16A-10DTQ
-2-
1. With internal EM reader.
2. Frequency: 125KHz.
3. Effective distance: 5cm.
4. ZONE 1: up to 1000 passwords & card holders.
ZONE 2: up to 10 passwords OR card holders..
5. Card access, code access and combined access.
6. Digital keypad operation.
7. Built-in pickproof function.
8. Watchdog timer, powerful reboot and self-recovery watchdog can connect with
the external unlock button.
9. Dual relay outputs.
10. Unlock output delay time: 0~99s.
11. IP rating: 65.
12. Dimension: 120*76*28mm.
13. Dual relay outputs for door opening, door status detecting, open door by button.
The function of door status detecting is for ZONE 1 only.
DH16A-20DT
DH16A-20DTQ
Working conditions:
o o
temperature: -20 C ~ +50 C
RH: ≤95%
Current and voltage requirements:
DC input: +12V - +24V
AC input: ~ 12V - 24V
standby current: ≤80mA
working current: ≤110mA
Applicable card mode:
EM ID card(Default)
T5557/T5567 card(Setting required)
Effective distance: 5cm
Capacity:
ZONE 1: up to 1000 passwords & card holders
ZONE 2: up to 10 passwords OR card holders
Mode indicator
Door indicator
Antenna
Matrix keypads
Case screw
NO. Description
Mode indicator
Door indicator
Antenna
Touch keypads
Case screw
Night-lighting indicator
NO. Description

-3-
1. With internal EM reader.
2. Frequency: 125KHz.
3. Effective distance: 5cm.
4. ZONE 1: up to 1000 passwords & card holders.
ZONE 2: up to 10 passwords OR card holders..
5. Card access, code access and combined access.
6. Digital keypad operation.
7. Built-in pickproof function.
8. Watchdog timer, powerful reboot and self-recovery watchdog can connect with
the external unlock button.
9. Dual relay outputs.
10. Unlock output delay time: 0~99s.
11. IP rating: 65.
12. Dimension: 120*76*28mm.
13. Dual relay outputs for door opening, door status detecting, open door by button.
The function of door status detecting is for ZONE 1 only.
DH16A-30DT
DH16A-30DTQ
Working conditions:
o o
temperature: -20 C ~ +50 C
RH: ≤95%
Current and voltage requirements:
DC input: +12V - +24V
AC input: ~ 12V - 24V
standby current: ≤80mA
working current: ≤110mA
Applicable card mode:
EM ID card(Default)
T5557/T5567 card(Setting required)
Effective distance: 5cm
Capacity:
ZONE 1: up to 1000 passwords & card holders
ZONE 2: up to 10 passwords OR card holders
-4-
1. With internal EM reader.
2. Frequency: 125KHz.
3. Effective distance: 5cm.
4. ZONE 1: up to 1000 passwords & card holders.
ZONE 2: up to 10 passwords OR card holders..
5. Card access, code access and combined access.
6. Digital keypad operation.
7. Built-in pickproof function.
8. Watchdog timer, powerful reboot and self-recovery watchdog can connect with
the external unlock button.
9. Dual relay outputs.
10. Unlock output delay time: 0~99s.
11. IP rating: 65.
12. Dimension: 123*79*21mm.
13. Dual relay outputs for door opening, door status detecting, open door by button.
The function of door status detecting is for ZONE 1 only.
DH16A-50DT
DH16A-50DTQ
Working conditions:
o o
temperature: -20 C ~ +50 C
RH: ≤95%
Current and voltage requirements:
DC input: +12V - +24V
AC input: ~ 12V - 24V
standby current: ≤80mA
working current: ≤110mA
Applicable card mode:
EM ID card(Default)
T5557/T5567 card(Setting required)
Effective distance: 5cm
Capacity:
ZONE 1: up to 1000 passwords & card holders
ZONE 2: up to 10 passwords OR card holders
Mode indicator
Door indicator
Antenna
Matrix keypads
Case screw
NO. Description
Mode indicator
Matrix keypads
Antenna
Case screw
NO. Description

-5-
Working conditions:
o o
temperature: -20 C ~ +50 C
RH:≤95%
Current and voltage requirements:
DC input: +12V - +24V
AC input: ~ 12V - 24V
standby current: ≤80mA
working current: ≤110mA
Applicable card mode:
EM ID card(Default)
T5557/T5567 card(Setting required)
Effective distance: 5cm
Capacity:
ZONE 1: up to 1000 passwords & card holders
ZONE 2: up to 10 passwords OR card holders
DH16A-60DT
DH16A-60DTQ
-6-
1. With internal EM reader.
2. Frequency: 125KHz.
3. Effective distance: 5cm.
4. ZONE 1: up to 1000 passwords & card holders.
ZONE 2: up to 10 passwords OR card holders.
5. Card access, code access and combined access.
6. Digital keypad operation.
7. Built-in pickproof function.
8. Watchdog timer, powerful reboot and self-recovery watchdog can connect with
the external unlock button.
9. Dual relay outputs.
10. Unlock output delay time: 0~99s.
11. IP rating: 65.
12. Dimension: 120*76*22mm.
13. Dual relay outputs for door opening, door status detecting, open door by button.
The function of door status detecting is for ZONE 1 only.
1. With internal EM reader.
2. Frequency: 125KHz.
3. Effective distance: 5cm.
4. ZONE 1: up to 1000 passwords & card holders.
ZONE 2: up to 10 passwords OR card holders..
5. Card access, code access and combined access.
6. Digital keypad operation.
7. Built-in pickproof function.
8. Watchdog timer, powerful reboot and self-recovery watchdog can connect with
the external unlock button.
9. Dual relay outputs.
10. Unlock output delay time: 0~99s.
11. IP rating: 65.
12. Dimension: 152*44*23.5mm.
13. Dual relay outputs for door opening, door status detecting, open door by button.
The function of door status detecting is for ZONE 1 only.
DH16A-12DT
DH16A-12DTQ
Working conditions:
o o
temperature: -20 C ~ +50 C
RH: ≤95%
Current and voltage requirements:
DC input: +12V - +24V
AC input: ~ 12V - 24V
standby current: ≤80mA
working current: ≤110mA
Applicable card mode:
EM ID card(Default)
T5557/T5567 card(Setting required)
Effective distance: 5cm
Capacity:
ZONE 1: up to 1000 passwords & card holders
ZONE 2: up to 10 passwords OR card holders
Mode indicator
Door indicator
Antenna
Matrix keypads
Case screw
NO. Description
Mode indicator
Matrix keypads
Antenna
Case screw
NO. Description

-7-
DH16A-32DTQ
DH16A-32DT
Working conditions:
o o
temperature: -20 C ~ +50 C
RH: ≤95%
Current and voltage requirements:
DC input: +12V - +24V
AC input: ~ 12V - 24V
standby current: ≤80mA
working current: ≤110mA
Applicable card mode:
EM ID card(Default)
T5557/T5567 card(Setting required)
Effective distance: 5cm
Capacity:
ZONE 1: up to 1000 passwords & card holders
ZONE 2: up to 10 passwords OR card holders
-8-
1. With internal EM reader.
2. Frequency: 125KHz.
3. Effective distance: 5cm.
4. ZONE 1: up to 1000 passwords & card holders.
ZONE 2: up to 10 passwords OR card holders..
5. Card access, code access and combined access.
6. Digital keypad operation.
7. Built-in pickproof function.
8. Watchdog timer, powerful reboot and self-recovery watchdog can connect with
the external unlock button.
9. Dual relay outputs.
10. Unlock output delay time: 0~99s.
11. IP rating: 65.
12. Dimension: 155*44*10mm.
13. Dual relay outputs for door opening, door status detecting, open door by button.
The function of door status detecting is for ZONE 1 only.
1. With internal EM reader.
2. Frequency: 125KHz.
3. Effective distance: 5cm.
4. ZONE 1: up to 1000 passwords & card holders.
ZONE 2: up to 10 passwords OR card holders..
5. Card access, code access and combined access.
6. Digital keypad operation.
7. Built-in pickproof function.
8. Watchdog timer, powerful reboot and self-recovery watchdog can connect with
the external unlock button.
9. Dual relay outputs.
10. Unlock output delay time: 0~99s.
11. IP rating: 65.
12. Dimension: 152*45*25mm.
13. Dual relay outputs for door opening, door status detecting, open door by button.
The function of door status detecting is for ZONE 1 only.
DH16A-52DT
DH16A-52DTQ
Working conditions:
o o
temperature: -20 C ~ +50 C
RH: ≤95%
Current and voltage requirements:
DC input: +12V - +24V
AC input: ~ 12V - 24V
standby current: ≤80mA
working current: ≤110mA
Applicable card mode:
EM ID card(Default)
T5557/T5567 card(Setting required)
Effective distance: 5cm
Capacity:
ZONE 1: up to 1000 passwords & card holders
ZONE 2: up to 10 passwords OR card holders
Mode indicator
Case screw
Touch keypads
Antenna
NO. Description
Mode indicator
Door indicator
Antenna
Matrix keypads
Case screw
NO. Description

-9-
1. With internal EM reader.
2. Frequency: 125KHz.
3. Effective distance: 5cm.
4. ZONE 1: up to 1000 passwords & card holders.
ZONE 2: up to 10 passwords OR card holders..
5. Card access, code access and combined access.
6. Digital keypad operation.
7. Built-in pickproof function.
8. Watchdog timer, powerful reboot and self-recovery watchdog can connect with
the external unlock button.
9. Dual relay outputs.
10. Unlock output delay time: 0~99s.
11. IP rating: 65.
12. Dimension: 165*45*23.5mm.
13. Dual relay outputs for door opening, door status detecting, open door by button.
The function of door status detecting is for ZONE 1 only.
DH16A-62DT
DH16A-62DTQ
Working conditions:
o o
temperature: -20 C ~ +50 C
RH: ≤95%
Current and voltage requirements:
DC input: +12V - +24V
AC input: ~ 12V - 24V
standby current: ≤80mA
working current: ≤110mA
Applicable card mode:
EM ID card(Default)
T5557/T5567 card(Setting required)
Effective distance: 5cm
Capacity:
ZONE 1: up to 1000 passwords & card holders
ZONE 2: up to 10 passwords OR card holders
1. With internal EM reader.
2. Frequency: 125KHz.
3. Effective distance: 5cm.
4. ZONE 1: up to 1000 passwords & card holders.
ZONE 2: up to 10 passwords OR card holders..
5. Card access, code access and combined access.
6. Digital keypad operation.
7. Built-in pickproof function.
8. Watchdog timer, powerful reboot and self-recovery watchdog can connect with
the external unlock button.
9. Dual relay outputs.
10. Unlock output delay time: 0~99s.
11. IP rating: 65.
12. Dimension: 150*44*24mm.
13. Dual relay outputs for door opening, door status detecting, open door by button.
The function of door status detecting is for ZONE 1 only.
DH16A-82DT
DH16A-82DTQ
Working conditions:
o o
temperature: -20 C ~ +50 C
RH: ≤95%
Current and voltage requirements:
DC input: +12V - +24V
AC input: ~ 12V - 24V
standby current: ≤80mA
working current: ≤110mA
Applicable card mode:
EM ID card(Default)
T5557/T5567 card(Setting required)
Effective distance: 5cm
Capacity:
ZONE 1: up to 1000 passwords & card holders
ZONE 2: up to 10 passwords OR card holders
-10-
Mode indicator
Door indicator
Antenna
Matrix keypads
Case screw
NO. Description
Mode indicator
Door indicator
Antenna
Matrix keypads
Case screw
NO. Description

-12-
o
20
Picture 1 Picture 2 Picture 3
Attention items of disassembly
(DH16A-10/12/20/30DT DH16A-10/12/20/30DTQ)
Shift the
front cover up
1. Please remove the cover carefully following the manual. Not
permitted to remove with sudden force.
2. Before remove the cover, push up the front cover a few
millimeters, then follow Picture 3, lift the lower cover for less
0
than 20 and remove the front cover gently.
1. With internal EM reader.
2. Frequency: 125KHz.
3. Effective distance: 5cm.
4. ZONE 1: up to 1000 passwords & card holders.
ZONE 2: up to 10 passwords OR card holders..
5. Card access, code access and combined access.
6. Digital keypad operation.
7. Built-in pickproof function.
8. Watchdog timer, powerful reboot and self-recovery watchdog can connect with
the external unlock button.
9. Dual relay outputs.
10. Unlock output delay time: 0~99s.
11. IP rating: 65.
12. Dimension: 150*44*24mm.
13. Dual relay outputs for door opening, door status detecting, open door by button.
The function of door status detecting is for ZONE 1 only.
DH16A-83DT
DH16A-83DTQ
Working conditions:
o o
temperature: -20 C ~ +50 C
RH: ≤95%
Current and voltage requirements:
DC input: +12V - +24V
AC input: ~ 12V - 24V
standby current: ≤80mA
working current: ≤110mA
Applicable card mode:
EM ID card(Default)
T5557/T5567 card(Setting required)
Effective distance: 5cm
Capacity:
ZONE 1: up to 1000 passwords & card holders
ZONE 2: up to 10 passwords OR card holders
-11-
Notice
Mode indicator
Door indicator
Antenna
Matrix keypads
Case screw
NO. Description

-13- -14-
Applicable model: DH16A-12/52/62/82/83DT
DH16A-12/52/62/82/83DTQ
Before installation, position the location where the controller unit is
mounted. Please operate it according to the following steps:
1. Open the controller and remove the back case at the bottom
with the special tool.
2. Use the provided drilling template to accurately locate and drill
the required holes. The four drilling holes are marked "B".
Then insert the screw anchors in the holes.
3. Use the screws provided to mount the back case on the wall. Be
sure to draw the wiring through the large centre hole in back
case, and keep level.
4. Connected accurately the system wiring following the label
enclosed on the rear.
5. Put the unit back and fasten it by using the special tool.
Before installation, position the location where the controller unit is
mounted. Please operate it according to the following steps:
Applicable model: DH16A-10/20/30/50/60DT
DH16A-10/20/30/50/60DTQ
1. Open the controller and remove the back case at the bottom
with the special tool.
2. Use the provided drilling template to accurately locate and drill
the required holes. The four drilling holes are marked "B".
Then insert the screw anchors in the holes.
3. Use the screws provided to mount the back case on the wall. Be
sure to draw the wiring through the large centre hole in back
case, and keep level.
4. Connected accurately the system wiring following the label
enclosed on the rear.
5. Put the unit back and fasten it by using the special tool.

-15-
Applicable model: DH16A-32DT DH16A-32DTQ
-16-
In the setting mode:
Press the button and , the mode indicator will flash yellow, follow
the button twice, the mode indicator will turn yellow, a long beep will
be heard. It indicates that only the card access is available.
Press the button and , the mode indicator will flash yellow, follow
the button and , the mode indicator will turn yellow, a long beep will
be heard, it indicates that both the card and code access are available.
Press the button and , the mode indicator will flash yellow,
follow the button and , the mode indicator will turn yellow and a long
beep will be heard, it indicates that card and code access combined is
available.
Press the button to quit the setting mode.
1. 2 relays can be programmed for opening the lock, up to
1000 user cards and correlative codes can be stored into ZONE 1, 10
user cards or codes can be stored into ZONE 2 . In addition, ZONE 1
can be programmed for 3 modes to open the lock: card access(use card
only), card and code access(use either card or code), and combined
access(use card and code together). ZONE 2 could be programmed for
door bell.
2. Default code is 1234.
3. Input the admin default code twice (1234+1234). But
a. If the admin default code you set is two digits, please input 12 12
b. If the admin default code you set is three digits, please input 123 123
c. If the admin default code you set is five digits, please input 1 2345
1 2345
The rest may be deduced by analogy...... The admin codes is max 6 digits.
After you enter in the setting mode, the yellow LED will be on.
ZONE 1 and
.
Access mode setting
NOTICE
In modes: DH16A-32/60DT DH16A-32/60DTQ,
the button replaces .
Before installation, position the location where the controller unit is
mounted. Please operate it according to the following steps:
1. Open the controller and remove the back case at the bottom
with the special tool.
2. Place the back case on the wall where the product will be located.
Mark on the wall according to the“B”letter. Then drill the four
holes on the wall and insert the serew anchors in the wall.
3. Use the screws provided to mount the back case on the wall. Be
sure to draw the wiring through the large centre hole in back
case, and keep level.
4. Connected accurately the system wiring following the label
enclosed on the rear.
5. Put the unit back and fasten it by using the special tool.
Questo manuale è adatto per i seguenti modelli
21
Indice
Altri manuali Competition Electronics Controllori di accesso IP