Connected Inventions AirWits R4.1 Manuale utente

AirWits R4.1
User manual!

Using this manual
Thank you for choosing this Connected Inventions device. This device will provide you high-
quality IoT with Connected Inventions’ exceptional technology and high standards. This
manual has been specially designed to guide you through the functions and features of your
device.
Read me first
• Before using your device, read the entire manual and all safety instructions to ensure safe
and proper use.
• The descriptions in this manual are based on the default settings of your device.
• The images used in this manual may differ from the actual product.
• The contents of this manual may differ from software provided by service providers or
carriers, and are subject to change without prior notice.
• Access the Connected Inventions website (www.connectedinventions.com) for the latest
version of the manual.
• Available features and additional services may vary by service provider.
• Applications on this device may perform differently from comparable applications and may
not include all functions available (by ie. downlink messaging features)
• Connected Inventions is not liable for performance issues caused by third-party
applications or improper installation.
• Please keep this manual for future reference.
• Maintenance
• In case of malfunction, deliver the device to the supplier. Do not open the cover.
• Transportation
• Do not remove packing material and do not repack the device unless necessary. Contact the
shipping agent before transportation. Inside the device there is a battery which contains
approximately 1.4 g of lithium.
• Disposal
• Return the device to a disposal station which collects electronics waste and batteries.
• Operation
• Protect the device from moist, water, and dirt.

About the device
Connected Inventions AirWits is a wireless temperature and humidity metering
device with ultra long battery life. This intelligent and small device measures and
sends the temperature and humidity data sequentially from 10 min to 24 hours
using the world-wide Sigfox IoT-network connectivity for data transmission,
enabling very low lifetime cost. The installation of the device is extremely simple
procedure and requires neither special tools nor configuration operation. The
device is maintenance free, and thus a great solution especially for long term
indoor temperature and humidity metering providing accurate data for energy
savings and comfortable living conditions which can be monitored remotely.
Functions
The basic functionality procedure example:
Diagram 1. Example of messages being sent and received
When the device is powered on, it will send the temperature and humidity
measurements and ask downlink message from the network. If the downlink
message is configured and reconfigure bit is 1, new settings will be adopted. In
case downlink message is not configured, the reconfigure bit is 0 or the downlink
message cannot be read, the previous settings will remain. The transmission
interval time and adaptive power control function can be set through downlink
message. After the downlink request, the device sends only uplink messages for
next 24 hours. After every 24 hours, the device will send downlink request again
within next payload transmission.
Temperature = 22.3
Humidity = 52
Request Downlink =
TRUE
Reconfigure = TRUE
Power Control = FALSE
Update interval = 30min
Temperature = 21.4
Humidity = 50
Request Downlink =
FALSE
Temperature = 22.3
Humidity = 52
Request Downlink =
TRUE
Reconfigure = FALSE
Power Control = FALSE
Update interval = —
…
~24h
30min
UL
DL

Assembling and Installation
• Save the identifier and the key of the device. The identifier and the PAC key is
on the label on the bottom of the device. You can also read the identifier and
the PAC key using the QR code.
Picture 1. Bottom label.
• Remove the battery strip from the device by pulling it away
Picture 2. Remove the battery strip by pulling it away.

• Install the wall plate to the wall using screws suitable for the wall material.
Please note the orientation!
Picture 3. Install the wall plate with appropriate screws.
•Attach the device to the wall having the pins meeting installation holes in the
device. Please note the orientation!
Picture 4. Attach the device to the wall plate.
1.
2.

• If your device came with double-sided tape option: NOTE! Remove any grease
and dirt from the wall surface. The tape is very powerful so be careful when
placing. After the device is placed, the bond is very strong. Removing the
device by force might break the surface the device is attached to. The tape is
not reusable, once it is removed from a surface, it will not bond reliably any
more.
Picture 5. Attachment with two-sided tape
Please note! Avoid placing device closer than 15cm on any metal or magnetic
object, electric cables, electric devices or selective glass as this will dramatically
reduce radio performance as well as battery life of the device. !

Replacing batteries
• NOTE! The device uses three (3) pieces of 3.6V, 2700mAh Lithium batteries.
You can purchase the suitable replacement batteries from your dealer. Do not
try to use other type of batteries- by example, 1.5V alkaline batteries will not
work on the device.
• Open the device by removing two screws on the backplate. Use PZ1 type
screwdriver
Picture 6. Open the device by removing the screws
• Pull the old batteries away from the device. Tape the ends of the old batteries
to avoid short circuits when recycling.
• Put new batteries into place. NOTE! The polarity for the batteries are same on
all three batteries. ENSURE ALL THE BATTERIES ARE INSTALLED SAME
WAY! Installing batteries incorrectly might destroy the device. If you are not
absolutely certain of polarity, please contact your dealer.
Picture 7. Put all the batteries same way!
+
+
+
-
-
-

Uplink: Payload description
Example
UL Message: 0x31026F34
BYTE
BIT
TYPE
DESCRIPTION
0
0-1
Reserved
0
2
Boolean
Full power mode. 1= TRUE, 0 = FALSE
0
3
Boolean
Active power control. 1= On, 0 = OFF
0
4-7
Uint4
FW version
1-2
0-15
UInt16
(Value /10) - 40 = Temperature [°C]
(Value /18) - 8 = Temperature [°F]
3
0-7
Uint8
Humidity [%]
0x1C = 00011100Bin
Full power = TRUE
Active power control = On
FW Version = 1
Header
0x026F = 623Dec
(623/10)-40 = 22,3 °C
Temperature
0x34 = 52Dec
52%
Humidity

Downlink
• Settings of the device can be updated with the downlink message
• Device requests new settings approximately every 24 hours
• You must be very careful when you update the settings
• settings affect both the subscription and the battery life of the device!
• Downlink message is optional
• If any downlink message is not received, device continues with the current settings
• How often messages are sent can be adjusted with the settings
•Default settings when device has not been configured with downlink:
•Uplink reporting period is 30minutes
•"Adaptive Power Control is OFF
•"Full transmit power is used
•If the Adaptive power control feature is set on, the device will automatically adjust
the transmit power to optimum level to save battery and create less unnecessary
interference to radio network
•By default power control is OFF
•When power control is OFF, full TX power is used
•NOTE! The Adaptive power control feature only available in RCZ1 device!
Altri manuali per AirWits R4.1
1
Indice
Altri manuali Connected Inventions Hardware di rete
Manuali Hardware di rete popolari di altre marche

Matrix Switch Corporation
Matrix Switch Corporation MSC-HD161DEL Manuale utente

B&B Electronics
B&B Electronics ZXT9-IO-222R2 Manuale utente

Yudor
Yudor YDS-16 Manuale utente

D-Link
D-Link ShareCenter DNS-320L Manuale utente

Samsung
Samsung ES1642dc Istruzioni per l’uso

Honeywell Home
Honeywell Home LTEM-PV Istruzioni per il montaggio