Table of Contents
1. HARDWARE CONFIGURATION........................................................................................................................4
1.1. PRODUCT INTERFACES .........................................................................................................................................4
2. RS-232 CONFIGURATION................................................................................................................................6
2.1. WINDOWS PLATFORM EXAMPLE............................................................................................................................6
2.2. LINUX PLATFORM EXAMPLE:.................................................................................................................................8
3. RADIO CONFIGURATION .............................................................................................................................. 11
4. SYSTEM CONFIGURATION ............................................................................................................................ 12
4.1. INITIAL IP SETUP...............................................................................................................................................12
4.2. SETUP NEW IP.................................................................................................................................................14
5. CONNECTING TO WIFI .................................................................................................................................. 18
6. SYSTEM MAINTENANCE ............................................................................................................................... 19
6.1. BACKUP THE CONFIGURATION.............................................................................................................................20
6.2. RESTORE THE CONFIGURATION............................................................................................................................21
6.3. RESET TO FACTORY DEFAULT UNDER WEB GUI ......................................................................................................21
7. FIRMWARE UPGRADE .................................................................................................................................. 22
8. MODEM ....................................................................................................................................................... 24
8.1. AT COMMAND.................................................................................................................................................24
8.2. APN CHANGE..................................................................................................................................................25
9. LOGS ............................................................................................................................................................ 26
9.1. SYSTEM LOG....................................................................................................................................................26
9.2. KERNEL LOG ...................................................................................................................................................26
10. ANTENNA ................................................................................................................................................. 27
10.1. DETACHABLE ANTENNA GUIDELINES.................................................................................................................27
10.2. DETACHABLE ANTENNA GUIDELINES.................................................................................................................27
10.3. ANTENNA –INSTALLATION GUIDELINES.............................................................................................................27
10.4. RECOMMENDED ANTENNAS............................................................................................................................28
11. ENVIRONMENTAL..................................................................................................................................... 29
11.1. OPERATING ENVIRONMENT ............................................................................................................................29
11.2. PHYSICAL PARAMETERS..................................................................................................................................29
12. APPROVALS AND CERTIFICATIONS ........................................................................................................... 30
12.1. MANUFACTURING.........................................................................................................................................30
12.2. NORTH AMERICAN CERTIFICATIONS..................................................................................................................30
12.3. ER2000T-NA-CAT1 &ER2000T-VZ-CAT1 ..................................................................................................30
12.4. ER2000T-NA-CAT1 ...................................................................................................................................30
12.5. ER2000T-VZ-CAT1 ....................................................................................................................................30
13. FCC GENERAL WARNING........................................................................................................................... 31
13.1. INDUSTRY CANADA (IC) NOTICES.....................................................................................................................32

© 2018 –Connected IO, Inc. 3 | P a g e
Introduction
Connected IO Inc’s., ER2000T is a 4G - CAT1 router for M2M applications. The Router includes a 4G modem
with an embedded host processor based on the Mediatek MT7620A SoC and supports 802.11 b/g/n WiFi
functionality. The 4G connectivity is made by an operator certified LTE module.
This document provides instructions, and basic operational guidelines, to aid a Systems Administrator with
the deployment of this product.
Connected IO
8304 Esters Boulevard, Suite 850,
Irving, TX 75063 USA
Phone: +1 (972) 366-0070
© 2018 Connected IO. All rights reserved.

4| P a g e © 2018 –Connected IO, Inc.
1. Hardware Configuration
1.1. Product Interfaces
Number
Item
Description
1
DC Power Input
12VDC @ 2.0A Input. Center conductor is Positive
2
Reset Button
Push & Release to reset the device
Push & Hold for 5-seconds then release installs factory preset
3
SIM Access
2FF Mini-SIM format
Slide the door open to access the SIM holder.
Push SIM into the holder to engage, push a second time to eject the SIM
Number
Item
Description
4
LAN Port
LAN Port for Wired Ethernet Clients
LED: Solid Green for Link, Flashing Green for Traffic
5
WAN Port
WAN Port for establishing links to leased telecommunication circuits
LED: Solid Green for Link, Flashing Green for Traffic
6
RS232 Port
Serial Communications port per EIA asynchronous data transfer
7
USB Port
Mini-USB 2.0 provides connectivity for optional storage or a USB
Ethernet dongle.
Port supplies up to 0.5A of 5V to connected devices.
1
2
3
24
6
5
7

© 2018 –Connected IO, Inc. 5 | P a g e
Number
Item
Description
8
WiFi Antenna
SMA connector for WiFi Antennas (NOT Reverse Polarized)
9
Cellular Antennas
SMA connector for both Primary and Diversity Antenna Ports
10
WiFi LED, Orange: Wifi is connected/Off: No WiFi
Power LED, Yellow: Power is connected/Off: unit is off
Cellcular Connection Strenght Indicators, Green: Cellcular
Connection
The following table lists the signal strength range corresponding to
the number of LEDs lit:
5-LEDs On: > -61dBm
4-LEDs On: -63 dBm to -71 dBm
3-LEDs On: -73 dBm to -83 dBm
2-LEDs On: -85 dBm to -98 dBm
1-LED On: -97 dBm to -107 dBm
No-LEDs: < -109 dBm
8
9
9
8
10

6| P a g e © 2018 –Connected IO, Inc.
2. RS-232 Configuration
The serial port communication on ER2000T series is a bidirectional asynchronous mode transfer mechanism
with the following default settings:
Data Rate: 9600bps
Date bits, Parity, Stop bit: 8N1
Flow Control: No
2.1. Windows Platform Example
TeraTerm software was used to demonstrate this tutorial in Windows mode.
1. Open TeraTerm serial connection
2. SSH into ER2000 series
From the router command line, do, for example, "ifconfig > /dev/ttyS0" and see results of the output in tera
term on Windows side.
Input (ER2000T-X-CAT1):

© 2018 –Connected IO, Inc. 7 | P a g e
Output (Windows Tera Term):

8| P a g e © 2018 –Connected IO, Inc.
From tera term, type a few keys and they will appear on the router side when "cat /dev/ttyS0" command is
run.
Input (Windows Tera Term):
Output (ER2000T-X-CAT1):
2.2. Linux Platform Example:
Minicom software was used to demonstrate this tutorial in Linux.
1. Open minicom serial connection
2. SSH into ER2000 series
From the router command line, do, for example, "ifconfig > /dev/ttyS0" and see results of the output in
minicom on Linux side.
Input(ER2000T-X-CAT1):

© 2018 –Connected IO, Inc. 9 | P a g e
Output (Linux Minicom or Putty):
From minicom, type a few keys and they will appear on the router side when "cat /dev/ttyS0" command is
run.

10 | P a g e © 2018 –Connected IO, Inc.
Input (Linux Minicom):
Output (ER2000T-X-CAT1):
Indice
Altri manuali Connected IO Router di rete
Manuali Router di rete popolari di altre marche

NETGEAR
NETGEAR FS526T - Switch Manuale utente

Korenix
Korenix JetNet 5710G Series Manuale utente

Automated Logic
Automated Logic ZN551 Manuale del proprietario

Cisco
Cisco ASR 1000 Series Manuale dell'operatore

EnGenius
EnGenius ESR-9710 Manuale utente

Cisco
Cisco 805 Series Istruzioni operative e di sicurezza