Maestro Opus Pedicure Chair
USER MANUAL
1-400-0088 • Rev A • 2/5/2020
© Continuum 2020, All Rights Reserved
*shown with oponal accessories and/or nishes

© Copyright 2020
Continuum®
All rights reserved. is document or
any portion thereof may not be repro-
duced in any way, including photocopy-
ing or translation to another language
without the prior written permission
from Continuum.
Continuum® is a registered trademark of
Earthlite, LLC,
Legal Notice
e information provided in this document is intended
for informational purposes only and is subject to change
without notice. e information provided in this docu-
ment should not be construed as a commitment by
Continuum®.
Continuum® assumes no responsibility for the accuracy
or suitability of the information contained in this docu-
ment. is document may contain technical inaccura-
cies or errors. Continuum® makes no expressed or im-
plied warranties of any kind concerning the information
contained in this document, including, but not limited
to, the implied warranties of merchantability and tness
for purpose.
Continuum® shall not be liable for incidental or conse-
quential damages in connection with or arising out of
the product, performance, or use of this document and
the information and material it describes.

Introduction
Congratulaons on your purchase of the Maestro Opus pedicure chair. The Maestro Opus has
a disncve design and bold lines set the standard for high-end, luxury pedicure chairs. The
Maestro Opus is packed with features that are sure to sasfy the most discerning clients, such
as dual seat controls, hand cut and sewn upholstery, solid surface basin, and Relaxor heat and
massage system.
The Maestro Opus is designed for licensed therapists and technicians and is intended to be used in
a professional spa, salon, or similar commercial environment. While no special training is needed
to operate the product, for safety reasons it is important that the instrucons contained in this
manual are reviewed in detail before the rst use. This manual should be read in its enrety by
each professional who will be operang the product to ensure the safety of both operator and
client. This manual should be saved for future reference.
The Maestro Opus should not be used in any other manner than described in this manual.
Please read, understand, and follow all safety warnings, labels, and instrucons. Misuse, use of
unnecessary force, or using the chair for unintended or unauthorized procedures can result in
injury to operator, client, and/or equipment.
Detailed instrucons for use and maintenance can be found in this user manual. If you have
further quesons, please contact us at (877) 255-3030 for US customers, or (760) 597-5707 for
internaonal customers. We can also be reached via e-mail at orders@connuumpedicure.com.
Secon 1: Safety Informaon
Safety Symbols/Warnings
Secon 2: Product Overview
Product Diagram
Product Specicaons
Secon 3: Operang Instrucons
Leveling Your Chair
Filling the Tub
Gravity Drain & Drain Pump
Jet System
Technician Controls
Chair Swivel
Electrical Specicaons
Client Controls
Secon 4: Care & Maintenance
Cleaning & Ongoing Maintenance
Tub Cleaning Guide
Troubleshoong
Warranty Informaon
Contact Us
2-3
4
5
6
6
7
7
8
8
8
9
10
11
12
13
back cover
Table of Contents

READ AND SAVE THESE INSTRUCTIONS
2
IMPORTANT SAFETY INSTRUCTIONS - FOR COMMERCIAL USE ONLY
Read all instructions before using this product.
Safety Symbols
Familiarize yourself with the following
Safety & Warning symbols. They are
designed to prevent damage and
injury to you, your clients, and your new
Continuum product.
IMPORTANT: The important safety
instructions and warnings in this manual
cannot cover all possible problems and
conditions that can occur. Use common
sense and caution when installing,
operating, or maintaining this appliance.
Indicates an imminently hazardous
situation which could result in serious
or fatal injury.
Indicates a potentially hazardous
situation which could result in serious
injury.
Indicates a potentially hazardous
situation which could result in
equipment damage and/or injury.
SECTION 1: SAFETY INFORMATION
RISK OF ACCIDENTAL INJURY OR DROWNING. DO NOT USE
DRUGS OR ALCOHOL BEFORE OR DURING USE. CHILDREN
OR HANDICAPPED PERSONS SHOULD NOT USE WITHOUT
SUPERVISION.
Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above
the body temperature of 98.6°F or 37°C. The symptoms of hyperthermia include an increase in the internal
temperature of the body, dizziness, lethargy, drowsiness, and fainting. The effects of hyperthermia include:
a) Failure to perceive heat,
b) Failure to recognize the need to exit the hydromassage bathtub,
c) Unawareness of impending hazard,
d) Fetal damage in pregnant women,
e) Physical inability to exit the hydromassage bathtub, and
f) Unconsciousness resulting in the danger of drowning. WARNING - The use of alcohol, drugs, or
medication can greatly increase the risk of fatal hyperthermia.
WARNING - RISK OF ELECTRIC SHOCK - Do not permit electric appliances (such as hair dryers,
lamp, telephone, radio, or television) to be within 5 ft (1.5m) of this unit.
WARNING - RISK OF INJURY - Exercise care when using a foot bath. Use this product for its
intended purpose: a manicure chair and ll and drain indoor commercial appliance for foot and ankle hydro
massage. DO NOT use attachments not recommended by manufacturer.
WARNING - MOVABLE PARTS, RISK OF INJURY:
• Keep children away from adjustable seat armrests, tilt back, and seat slide, and footrest.
WARNING - To reduce the risk of burns, re, electric shock, or injury to persons:
• Unplug from outlet before putting on or taking off parts.
• Close supervision is necessary when this furnishing is used by, or near children, invalids, or disabled
persons. DO NOT leave children alone or allow them to operate the controls. Keep controls out of
reach of children. DO NOT allow children to crawl behind the chair.
• Never use this furnishing if it has a damaged cord or plug, if it is not working properly, if it has been
dropped or damaged, or dropped into water. Return the furnishing to a service center for examination
and repair.
• Keep the cord away from heated surfaces.
• Never operate the furnishing with the air openings blocked. Keep the air openings free of lint, hair, etc.
• Never drop or insert any object into any opening.
WARNING - RISK OF HYPERTHERMIA AND POSSIBLE DROWNING. WATER
TEMPERATURE IN EXCESS OF 38°C or 100.4°F CAN BE INJURIOUS TO YOUR HEALTH.
CHECK AND ADJUST WATER TEMPERATURE BEFORE USE.

READ AND SAVE THESE INSTRUCTIONS 3
SECTION 1: SAFETY INFORMATION
• DO NOT reach for any electrical object that has fallen into the water. Unplug immediately.
• DO NOT drop or insert anything into jet opening.
• DO NOT operate without the complete jet assembly installed or without water lled 1 inch above jets.
• DO NOT overll the basin.
• DO NOT stand on or in the basin, or on the foot rest.
• DO NOT leave this appliance unattended when in operation.
• DO NOT use outdoors.
• DO NOT swivel when chair is in tilt position.
• Keep the electrical cord away from heated surfaces.
• Connect this appliance only to a properly grounded outlet.
• To avoid injury, exercise care when entering or exiting the chair and foot bath.
• Use caution when making positioning adjustments to your chair. Keep all equipment and body parts
away from moving parts while making any adjustments.
• It is important that you clean and disinfect the jets and basin after every use.
• Hydrotherapy should be pleasant and comfortable. Should you or a client experience any pain or
discomfort while using the foot bath, discontinue use immediately and consult a physician.
• You or your clients should consult a physician if diabetic, have poor circulation, if feet or legs are in-
amed, have an open wound, or if you have questions about whether you should be using hydro mas-
sage equipment.
• A licensed plumber and electrician are strongly recommended to install your foot bath.
• Make certain that the cord and plug are maintained in good condition and are not allowed to become
damaged while in use. Avoid positioning the cord in the trafc lane and it is always kept out of the way.
Take this furnishing out of service immediately if the cord or plug becomes damaged in any way.
• Do not attempt to repair. All repairs must be performed by an authorized service representative.
1. RISK OF ELECTRIC SHOCK. Connect only to a circuit protected by a ground-fault
circuit-interrupter (GFCI).
2. Grounding is required. The unit must be installed by a licensed electrician and
grounded.
This product must be grounded. If it should malfunction or break down, grounding provides a path of
least resistance for electric current to reduce the risk of electric shock. This product is equipped with
a cord having an equipment-grounding conductor and grounding plug. The plug must be plugged into
an appropriate outlet that is properly installed and grounded in accordance with all local codes and
ordinances.
Improper connection of the equipment-grounding connector can result in a risk of electric shock. Check
with a qualied electrician or serviceman if you are in doubt as to whether the product is properly grounded.
Do not modify the plug provided with the product - if it will not t the outlet, have a proper outlet installed by
a qualied electrician.
INSTALLATION INSTRUCTIONS / GROUNDING INSTRUCTIONS
Reset
Button
GFCI Outlet
Grounding Pin
Test
Button
IMPORTANT: See separate
installation instructions
for detailed installation
information.

SECTION 2: PRODUCT OVERVIEW
4
Chair Swivel
Release
Drain Pump
Button
(Optional)
*Chair shown with oponal nishes
Sprayer/Fill
Electronic
Footrest
Client Controls
Drain Pump
Button
Drain
Release
Cupholder
Water Fill
Valve
Pipeless Jet
Light Button
Jet Button
Technician
Controls
Vent
USB Port

Length 61.25” (156 cm)
Width 36” (92 cm)
44.75” (113 cm), with side trays
Overall Height 52” (132 cm)
Seat Height 23.5” (60 cm)
Weight Capacity 300 lbs
Basin Capacity 5.7 gallons
*Measurements may vary due to natural material variaons.
5
Feature Standard Oponal
Power chair posioning/recline X
Pipeless magnec jet system X
Glass Basin X
Swivel seat X
Relaxor Heat & Massage X
Dual client/tech seat controls X
Cupholder X
Integrated Venlaon X
USB Port X
Drain Pump X
Manicure trays X
Full concealment side panels X
Upholstery Premium
Ultraleather
Custom
upholstery
Included Features
Product Specications
SECTION 2: PRODUCT OVERVIEW

SECTION 3: OPERATING INSTRUCTIONS
6
Leveling Your Chair
Leveling, or balancing, your chair is very important during ini al setup and rou ne maintenance.
Your Maestro Opus is equipped with six (6) leveling feet.
NOTE: Leveling feet have been adjusted prior to shipment - in most cases no further adjustment
should be necessary. The en re pedicure chair may be raised or lowered slightly to ensure the
technicianʼs chair touches the front stainless steel guard and not the wood or Formica®
To adjust the leveler feet:
1. Place the chair in the posi on you plan to use it.
2. To determine which foot needs adjus ng, a empt to “rock” the chair. If there is any
movement, the leg that is li ing is the one that will need adjus ng.
3. Using your hand, or a wrench if necessary, turn the leveling foot in the needed direc on.
(Counterclockwise will lower the overall height, clockwise will raise the overall height)
Filling the Tub
Locate the chrome hot/cold water valve handle on the front of your pedicure chair. This valve
handle controls both the fl ow of water and the temperature of water. Note: The sprayer/ ller
has a dual func on; it is both a sprayer and ller for the basin.
When desired water temperature is achieved, close “Pop-Up” in bo om of basin by turning
chrome drain handle located on right side of the base. (Figure 2)
When water level reaches a point approximately one (1) inch ABOVE the top edge of the jet (or
the ll line indicated by a s cker in the basin), shut water o by pressing down on the handle.
There is no automa c shuto with the water ll valve. You MUST turn the
valve OFF a er the tub is lled to prevent overfl ow and/or fl ooding. Do not
walk away from the tub when it is lling with water.
Turn Right
for Cold
Turn Le
for Hot
Turn to close
pop-up drain
Drain Pump
Bu on (Op onal)

7
SECTION 3: OPERATING INSTRUCTIONS
Jet System
The pipeless “magne c” system is standard in your pedicure unit. A er basin is lled to proper
level, turn jet on by pressing the chrome bu on marked “JET”. To turn o , press “JET” bu on a
second me.
NOTE: Liners can be used on a “magne c” system. The liner has to sit between the motor
housing and the wet end assembly.
The jet assembly must be correctly assembled or it may be damaged. This
will NOT be covered by any Con nuum warranty. Never turn the jet on
without adequate water in the basin. There must be at least one (1) inch of
water above the motor housing.
Draining the Tub
1. Gently turn drain handle located on right side of base. This ac vates “Pop-Up” located on
bo om of basin allowing water to drain.
2. Wait for the air bubbles to exit. Press chrome bu on marked “DRAIN” to ac vate pump.
3. When basin is fully emp ed, press bu on again to turn the pump o .
NOTE: Drain pump will automa cally turn o in four (4) minutes if bu on is not pressed a
second me
Drain Pump
Bu on (Op onal)
ALWAYS perform Step 1 before Step 2. Never reverse the steps as this may
cause the “Pop-Up” to become jammed in the waste assembly.
Drain Handle
Correctly
placed
impeller
Jet
Cover
Jet housing

SECTION 3: OPERATING INSTRUCTIONS
8
Electrical Specications
Spec North America Europe/Asia
Input Voltage 120 VAC 220 VAC
Input Frequency 60 Hz 50 Hz
Total Consumpon
- Standard Features 9A 4.5A
Technician Controls
See below for technician controls funconality.
Raise/lower
right footrest Slide seat
forward/backward
Always use extreme cauon when making any posion adjustments to the
chair. Ensure all body parts and objects are clear from all moving parts.
Raise/lower
le footrest
Chair Swivel
The Chair Release Lever is on the le side of the chair. Gently li up on the lever allowing the
chair to swivel. This must be done each and every me a client enters or exits the chair.
Please note: In order for the chair locking mechanism to work properly, one must sit normally
in the chair, that is to say, NOT on the outer edge of the chair, but rather sing back in the
chair. This allows for the locking pin to engage and disengage easily.
When entering: Li lever allowing chair to swivel either le or right. With client seated, swivel
chair to front posion unl a click is heard. This safely locks the chair in place.
When exing: Li lever allowing chair to swivel either le or right unl a click is heard. This
safely locks the chair allowing exit.
Make sure each client moves slowly and carefully. ONLY enter and exit chair
when it is in a locked posion.
Altri manuali per Maestro Opus