CoolAutomation CoolPLug Manuale utente

CoolPlug CooLinkHUB HVAC Bridge CooLinkHUB + CoolPlug
QIG Version 2.2 2 CoolPlug CooLinkHUB
Table of Contents
1. CooLinkHUB + CoolPlug...............................................................................................5
1.1 System Overview ...............................................................................................5
1.2 Network Topology ..............................................................................................5
1.3 CoolPlug Models................................................................................................5
1.4 What’s in the box................................................................................................6
2. Connecting CoolPlug ....................................................................................................7
2.1 DK (Daikin) –S21...............................................................................................7
3. Connecting CoolPlug DK (Daikin) .................................................................................8
3.1 DK (Daikin) –P1 P2...........................................................................................8
4. Connecting CoolPlug DKS............................................................................................9
4.1 DK (Daikin) –Siesta Series................................................................................9
5. Connecting CoolPlug PN/SA/TO.................................................................................10
5.1 Panasonic | Sanyo | Toshiba............................................................................10
6. Connecting CoolPlug FJ..............................................................................................11
6.1 FJ (Fujitsu/General) - Option 1*........................................................................11
6.2 FJ (Fujitsu/General) - Option 2*........................................................................12
6.3 FJ (Fujitsu/General) - Option 3*........................................................................13
7. Connecting CoolPlug ME (Mitsubishi Electric).............................................................14
7.1 Option 1 –CN-105 ...........................................................................................14
8. Connecting CoolPlug MH (Mitsubishi Heavy)..............................................................15
8.1 Option 2 –[1] [2]...............................................................................................15
9. Connecting CoolPlug HT (Hitachi)...............................................................................16
10. Connecting CoolPlug LG (LG).....................................................................................17
11. Connecting CoolPlug Gree (GRTS).............................................................................18
11.1 Gree Option 1...................................................................................................18
11.2 Gree Option 2...................................................................................................19
11.3 Gree Option 3 (H1,H2) .....................................................................................20
12. Connecting Home Automation, BMS & CoolRemote...................................................21
13. CoolRemote App.........................................................................................................22
14. CoolPlug Operation.....................................................................................................23
14.1 CoolPlug Indicators..........................................................................................23
14.2 CoolPlug Normal Operation..............................................................................23
15. Wireless CoolPlug & CooLinkHUB –Installation Guidelines........................................25
15.1 Rebuilding the wireless mesh network..............................................................26
16. Mounting the CoolPlug................................................................................................27

CoolPlug CooLinkHUB HVAC Bridge CooLinkHUB + CoolPlug
QIG Version 2.2 3 CoolPlug CooLinkHUB
Safety Guidelines, Warnings and Cautions
Read and understand the following guidelines to ensure a safe installation.
Warnings
Failure to follow WARNING may result in injury or death.
This equipment is to be installed by an accredited electrician or equivalent technical
person, as per
theseinstallationinstructions.
Read the installation instructions before connecting
the system to the power source.
All electrical work must be performed by a licensed technician, according to local regulations.
Ultimate disposal of this product should be handled according to all national laws and
regulations.
Installation of the equipment must comply with local
and national electrical legislation for
installation of
electric equipment.
Do not install the devices outdoors or exposed to
direct solar radiation, water, high relative
humidity
or dust.
Install the equipment only in a restricted access
location.
When wall mounting, be sure to fix firmly on a stable
surfaceandinaccordance tothe
instructions below.
When DIN rail mounting, fix the devices properly to
the DIN rail following the instructions
below.
When mounting on DIN rail inside a metallic cabinet
be sure to properly connect to earth.
Unplug powerwhen connecting the wires.
Pay attention to the polarity of powerand
communication cables when connecting them.
Disconnect power of any bus or communication cable beforeconnecting the system.
Cautions
Failure to follow CAUTION may result in serious injury.
Do not allow children to play with the CoolPlug or CooLinkHUB.
Do not disassemble, modify or repair the CoolPlug or CooLinkHUB, do contact
CoolAutomation for support. Unauthorized modifications or repairs may result in electric
shock or fire.
Do not expose the CoolPlug or CooLinkHUB to moisture. Water can damage the
CoolPlug or CooLinkHUB resulting in an electrical components failure, electric shock or
fire.

CoolPlug CooLinkHUB HVAC Bridge CooLinkHUB + CoolPlug
QIG Version 2.2 4 CoolPlug CooLinkHUB
Do not use flammable materials (e.g. hairspray or insecticide) near the CoolPlug or
CooLinkHUB. Do not clean the CoolPlug or CooLinkHUB with organic solvents such as
paint thinner.
Use only a dry cloth to wipe if necessary. The maximum voltage that can be directly
applied to the CooLinkHUB is 24V DC. Do not apply AC110V or AC220V to the
CooLinkHUB or CoolPlug.
DO NOT INSTALL the COOLINKHUB or COOLPLUG IN THE FOLLOWING
LOCATIONS:
a) Where mineral oil mist or oil spray or vapor is produced, for example, in a kitchen.
Plastic parts may deteriorate and fall off.
b) Where corrosive gas, such as sulfurous acid gas, is produced.
c) Near machinery emitting electromagnetic waves. Electromagnetic waves may
disturb or damage the operation of the CooLinkHUB.
d) Where flammable gas may leak, where there is carbon fiber or ignitable dust
suspensions in the air, or where volatile flammables such as thinner or gasoline are
handled. Operating the CooLinkHUB or CoolPlug in such conditions may cause a
fire.
e) In high temperature areas or near any flame.
f) In moist areas, or where there is exposure to water.

CoolPlug CooLinkHUB HVAC Bridge CooLinkHUB + CoolPlug
QIG Version 2.2 5 CoolPlug CooLinkHUB
1. CooLinkHUB + CoolPlug
1.1 System Overview
The CooLinkHUB + CoolPlug is a solution for complete integration of Multi-Split and Mini-
Split HVAC units. The CoolPlug - HVAC designated adapter, connects directly to the HVAC
indoor unit on one side, and to the CooLinkHUB on the other, via a PBUS Network.
The CooLinkHUB - protocol converter allows integration to any Home Automation system.
1.2 Network Topology
The PBUS is a Cool Automation’s proprietary Bus,
running on a shielded twisted pair cable
(24AWG).
The
PBUS utilizes free network topology (‘star’, ‘daisy-
chain’, etc.) No loops allowed.
Up to 10 CoolPlugs can be connected in a single PBUS network.
1.3 CoolPlug Models
CoolPlug models are HVAC manufacturer specific. The letters on the sticker (DK, DKS, etc.)
indicate the HVAC manufacturer the CoolPlug relates to.

CoolPlug CooLinkHUB HVAC Bridge CooLinkHUB + CoolPlug
QIG Version 2.2 6 CoolPlug CooLinkHUB
1.4 What’s in the box
1.4.1 CooLinkHUB
▪CooLinkHUB Unit
▪USB cable
▪RS-232 cable
▪Power supply
(Universal or EU –according to SN)
1.4.2 CoolPlug
▪CoolPlug Unit
▪CoolPlug back plate for adding two magnets
▪CoolPlug back plate for adding two stamps
▪Two stamps
▪Two magnets
▪Optional: Terminal cable
(according to the specific plug model as indicated on the above table.

CoolPlug CooLinkHUB HVAC Bridge Connecting CoolPlug
QIG Version 2.2 7 CoolPlug CooLinkHUB
2.
ConnectingCoolPlug
2.1 DK (Daikin) –S21
1
Connecting the CoolPlug to the Daikin unit
ConnecttheS21cablesuppliedwith
theCoolPlug,betweenthe CoolPlugRJ-11
connectorandthe S21 port onthe indoor
unit’s PCB. Consult HVAC
manufacturer’s
installationmanual
forlocationofS21onControlBoard.
2
Connecting the CoolPlug to the CooLinkHUB
Connect the signal wires of the PBUS cable between CoolPlug terminals [-], [1] and
[2], and CooLinkHUB terminals [VDC-], [1] and [2], respectively.
* See page 5 for system overview, no point-to-point connectivity required.

CoolPlug CooLinkHUB HVAC Bridge Connecting CoolPlug DK (Daikin)
QIG Version 2.2 8 CoolPlug CooLinkHUB
3.
Connecting CoolPlug DK (Daikin)
3.1 DK (Daikin) –P1 P2
1
Connecting the CoolPlug to the Daikin unit
Connect the CoolPlug’s [P1], [P2] terminals to the [P1], [P2] terminals on the indoor
unit.*
2
ConnectingtheCoolPlugtothe CooLinkHUB
Connect the signal wires of the PBUS cable coming from the [VDC-], [1] and [2]
terminals on the CooLinkHUB to the corresponding [-], [1] and [2] terminals on the
CoolPlug, respectively.
Optional: Connect the Wired Remote Controller (W.R.C.) in parallel mode.
* No Polarity requirements

CoolPlug CooLinkHUB HVAC Bridge Connecting CoolPlug DKS
QIG Version 2.2 9 CoolPlug CooLinkHUB
4.
Connecting CoolPlug DKS
4.1
DK (Daikin) –Siesta Series
1
Connecting theCoolPlug HVAC Line to the Daikin Siesta Indoor Unit
Connect the cable, supplied with the CoolPlug, to the port labeled “Indoor” on CoolPlug
and the corresponding connector on the indoor unit.
2
Connecting the CoolPlug to the CooLinkHUB
Connect the signal wires of the PBUS cable, using [VDC-], [1] and [2] terminals on the
CooLinkHUB, to the corresponding [-], [1] and [2] terminals on the CoolPlug.
3
Optional: Connect the wired remote to the ‘W.R.C’ socket on the CoolPlug. The
cable is supplied with the W.R.C.

CoolPlug CooLinkHUB HVAC Bridge Connecting CoolPlug PN/SA/TO
QIG Version 2.2 10 CoolPlug CooLinkHUB
5. Connecting CoolPlug PN/SA/TO
5.1 Panasonic | Sanyo | Toshiba
1
Connecting theCoolPlug HVAC Line to the PN/SA/TO Indoor Unit
Connect the CoolPlug’s [A], [B] terminals to [A], [B] terminals on indoor unit.
* To connect to Panasonic indoor unit, use R1 R2 terminals.
2
ConnectingtheCoolPlugtotheCooLinkHUB
Connect the signal wires of the PBUS cable coming from the [VDC-], [1] and [2]
terminals on the CooLinkHUB to the corresponding [-], [1] and [2] terminals on the
CoolPlug.
3Optional: Connect the Wired Remote Controller (W.R.C.).