qheat DTHERMZ5 10/2015
3
Installation & User Guide qheat room sensor

10/2015 DTHERMZ5 qheat
4
Installation & User Guide qheat room sensor

Introduction
qheat RS is a battery operated temperature sensor.
When included into Z-Wave wireless network, its buttons can also
be used to control the heating system.
LED button
Temperature UP
Display (backlit)
Temperature DOWN
Installation
1. Remove the back panel by
sliding it downwards.
2. Insert the batteries.
3. Fix the back panel to the wall. 4. Gently slide qheat RS on the
back panel.
GB
qheat DTHERMZ5 10/2015
5
Installation & User Guide qheat room sensor

Display Information
Display LED Explanation
Room temperature displayed
Green fast flash Inclusion or exclusion in progress
Red flash Inclusion or exclusion failed
(blinks)
The qheat RS is included, but does not
get any reply from the Controller
Red flash every
150 second Low battery level
Red flash every
30 second Critical battery level
Tamper-proof enabled by the controller
Z-wave info
Generic Device Class Multilevel sensor
Specific Device Class Routing Multilevel Sensor
Device type Routing slave
SDK 4.55
NWI Yes
Explorer frames Yes
Manufacturer ID 0x0002
Product Type ID 0x0248
Product ID 0xA020
10/2015 DTHERMZ5 qheat
6
Installation & User Guide qheat room sensor

Z-wave command classes
Command Class Version Description
BASIC V1
• Basic SET: Not Supported
• Basic GET: Multilevel Sensor Get
• Basic REPORT: Multilevel Sensor
Report (1°C accuracy)
MANUFACTURER_
SPECIFIC V2 Danfoss and qheat RS IDs
VERSION V2 Version of the command classes,
the Z-wave library and the qheat RS
BATTERY V1 Battery status
MULTI_CMD V1 Conserve battery, transmitting multi-
ple commands in a single packet
WAKE_UP V2 Wake-up interval range 5 min. to
24h (default: 60 minutes)
PROTECTION V2 0 = No protection
2 = User interface locked
CONFIGURATION V2 qheat RS specific configuration.
SENSOR_
MULTILEVEL V6 Reports reading from the room
temperature sensor.
CENTRAL_SCENE V1
Pushing the LED button triggers
transmission of CENTRAL_SCENE_
NOTIFICATION.
THERMOSTAT_
SETPOINT V2
When a set-point temperature is
selected on the display, a set-point
report containing the value is sent to
the controller.
SCHEDULE V1
When a temperature and number of
hours are selected on the display,
an override schedule report will be
sent to the controller containing
the values.
INDICATOR V1 Control of the LED indication.
GB
qheat DTHERMZ5 10/2015
7
Installation & User Guide qheat room sensor

Functions
1. Room Temperature Sensor
Command Class SENSOR_
MULTILEVEL
The room temperature can
be read on the display, as
indicated by the icon . When
included into Z-Wave network,
a temperature report is sent to
the controller during wake-up
and also when the temperature
has changed beyond configured
threshold limit.
Display accuracy 0.1°C
Sensor read Every 5 min.
Report sent During WakeUp
If report thresh-
old passed
CONFIGURATION COMMAND
CLASS Default Range
Report threshold 0.5°C 0.1 to 10°C
2. Toggle Switch
Command Class CENTRAL_
SCENE
When the LED button is clicked
a CENTRAL_SCENE_NOTIFICA-
TION is sent to the controller.
Supported key
attributes
0x00 / 0x01 /
0x02
3. Control of LED
Command Class INDICATOR The controller can start and
stop a flashing indication of the
LED button using the Indicator
Set command. The frequency,
number of flashes and color of
the session are controlled by 4
configuration parameters.
Indicator Set 0xFF = Start
LED flash
session
0x00 = Stop
running session
CONFIGURATION COMMAND
CLASS Default Range
LED on time 100
ms
100 to 500 ms in 100
ms steps
LED Flash period 1 s 0 to 65535 seconds
Number of LED flashes (duration) 5 0 to 255 flashes
LED Colour Green Green, Red
10/2015 DTHERMZ5 qheat
8
Installation & User Guide qheat room sensor

4. Change Set-Point
Command Class THERMOSTAT_
SETPOINT
The up and down arrow buttons
are used to select a new set-
point temperature.
After a set-point has been se-
lected, it will flash for 5 seconds.
After that the measured tem-
perature is displayed again and
the qheat RS sends the selected
temperature as a THERMO-
STAT_SETPOINT_REPORT to
the Z-Wave controller.
CONFIGURATION COMMAND
CLASS Default Range
Setpoint control function Enabled Disabled / enabled
Set-point display resolution 0.5°C From 0.1 to 10°C
in 0.1°C steps
Max set-point and override limit 28°C
From min setpoint/
override limit to
max 40°C
Min set-point and override limit 12°C
From min 0°C to
max. setpoint/over-
ride limit
Setpoint Type in Thermostat_
Setpoint_Reports Heating #1
Heating #1,
Cooling #1,
Auto Changeover
GB
qheat DTHERMZ5 10/2015
9
Installation & User Guide qheat room sensor

5. Override Thermostat Scheduler
Command Class SCHEDULE The up and down arrow buttons
are used to select the temporary
override temperature.
The selected value flashes on
the display for 5 seconds.
Before the 5 seconds are gone,
push the LED button to select
number of hours to override.
The selected number of hours
will flash for 5 seconds. After
that the measured temperature
is displayed again and the qheat
RS sends the selected tempera-
ture and the number of hours
as a SCHEDULE_REPORT to the
Z-Wave controller.
CONFIGURATION COMMAND
CLASS Default Range
Temporarily override scheduler Enabled Disabled / Enabled
Set-point display resolution 0.5°C From 0.1 to 10°C in
0.1°C steps
Max set-point and override limit 28°C
From min setpoint/
override limit to
max. 40°C
Min set-point and override limit 12°C
From min 0°C to
max. setpoint/over-
ride limit
10/2015 DTHERMZ5 qheat
10
Installation & User Guide qheat room sensor

Configuration Command Class
No. Configuration
parameter
Default Range Encoding
1 Temperature
Report threshold
0.5°C 0.1 to 10°C 2 bytes
1 = 0.1°C
100 = 10.0°C
2 Set-point display
resolution
0.5°C From 0.1 to
10°C in 0.1°C
steps
2 bytes
1 = 0.1°C
100 = 10.0°C
3 Min set-point and
override limit
12°C From min
0°C to max
setpoint/
override limit
2 bytes
0 = 0°C
40 = 40°C
4 Max set-point and
override limit
28°C From min
setpoint/
override limit
to max 40°C
6 Setpoint control
function
Enabled Disabled /
enabled
1 byte
0 = Disabled
1 = Enabled
7 Temporarily over-
ride scheduler
Enabled Disabled /
enabled
8 Setpoint Type in
Thermostat_
Setpoint_Reports
Heating Heating #1,
Cooling #1,
Auto
Changeover
1 byte
1 = Heating #1
2 = Cooling #1
10 = Auto
Changeover
9 LED on time 100ms 100 to
500ms in
100ms steps
1 byte
1 = 100ms
5 = 500ms
5 LED Flash period 1s 0 to 65535
seconds
2 bytes
10 Number of LED
flashes (duration)
5 0 to 255
flashes
1 byte
11 LED Color Green Green, Red 1 byte
0x01 = Green
0x02 = Red
GB
qheat DTHERMZ5 10/2015
11
Installation & User Guide qheat room sensor

Z-Wave Networks
The qheat RS can be included and operated in any Z-Wave network
with other Z-Wave certified devices from any other manufacturers.
All constantly powered Z-Wave nodes in the same network will act as
repeaters regardless of the vendor.
Z-Wave best practice
• After a successful “Inclusion” the controller must send a WAKE_UP_
INTERVAL_SET command to the qheat RS in order to specify where
and when the qheat RS should communicate wirelessly.
• After sending the WAKE_UP_INTERVAL_SET command, the controller
must assign return routes, so the qheat RS can reach its destination
i.e. the nodeID set in the WAKE_UP_INTERVAL_SET command.
• The nodeID set in the WAKE_UP_INTERVAL_SET command must be
for a permanently listening device which responds to the commands
sent from the qheat RS. If the controller is turned o for extended
periods, the qheat RS will use the batteries too fast.
• Although the qheat RS supports single commands, multi commands
must always be used to ensure long battery lifetime.
Z-Wave Inclusion
• Ensure that the qheat RS is factory reset.
• Activate “Inclusion” on the Z-Wave controller.
• Press the LED button on the qheat RS.
• Observe both controller and qheat RS for status of the process.
Z-Wave Exclusion
• Activate “Exclusion” on the Z-Wave controller.
• Hold down the 3 buttons on the qheat RS for 5 seconds (up, down
and LED buttons).
• Observe both controller and qheat RS for status of the process.
10/2015 DTHERMZ5 qheat
12
Installation & User Guide qheat room sensor