www.CookingPerformanceGroup.com
81-800-678-5517
USER MANUAL
TROUBLESHOOTING
Symptoms Causes Solutions
The pilot ame cannot be lit.
1. Plug or plug cord of igniter is
damaged.
2. Pressure in the gas pipeline is too low.
3. The pilot nozzle is blocked.
4. Thermocouple connection is loose.
5. The thermocouple is defective.
6. The gas control valve is defective.
1. Replace relevant ttings.
2. Regulate the reducing valve or contact
the gas supplier.
3. Unblock the nozzle.
4. Tighten the thermocouple.
5. Replace the thermocouple.
6. Repair or replace the gas control valve.
The pilot ame is on but the main
burner cannot be lit.
1. Pressure in the gas pipeline is too low.
2. Main nozzle is blocked.
3. The gas control valve is defective.
1. Regulate the reducing valve or contact
the gas supplier.
2. Unblock the nozzle.
3. Repair or replace the gas control
valve.
There is a light-back sound when
turning o the gas supply.
1. Nozzle diameter does not match with
the gas supply.
2. The supply pressure is too low.
3. Flow within the connected pipe is too
low.
1. Regulate the nozzle diameter.
2. Regulate the reducing valve or contact
the gas supplier.
3. Increase the permitted ow.
Unit has red ame and black smoke.
1. Nozzle diameter does not match with
the gas supply.
2. Low gas supply.
3. Gas ingredients are volatile in gas
peak period.
1. Regulate the nozzle diameter.
2. Increase the gas supply.
3. Decrease the gas ow. Increase it after
the peak.
The issues mentioned above are for reference. If any failure occurs, please stop using and contact
Cooking Performance Group. Safety is rst and maintenance should be done after shutting down the