Crane EE-9003 Manuale utente

Crane Double Electric Breast Pump
EE-9003
PLEASE READ AND SAVE ALL INSTRUCTIONS TO ENSURE
THE SAFE AND EFFECTIVE USE OF THIS BREAST PUMP.
If you have any questions about the operation of your breast
pump, please contact Crane Customer Care.
Toll Free: 888-599-0992
Email: customer-service@crane-usa.com
Register your product online
https://crane-usa.com/product-registration/

2
SAVE YOUR DATED PROOF OF PURCHASE!
[ You will need this in case of warranty ]

3
Congratulations on choosing the Crane Double Electric Breast
Pump. The Crane Double Electric Breast Pump is designed to
mimic a baby’s natural sucking. Use it to express your milk
efficiently in whisper quiet comfort. The soft silicone breast
cushion and easily adjustable modes help to stimulate milk let
down, while gently massaging and squeezing the breast and
nipple.
Cleaning, caring for and using your pump is a breeze with the
built-in rechargeable battery, fully enclosed system with anti-
backflow and easy to assemble 2-piece silicone soft breast
shield and milk collection sets.
Design for Better Living.
TABLE OF CONTENTS
Safety Instructions
Pg. 4-5
Functions and Features
Pg. 6
Parts
Pg. 7-8
Assembling Your Crane Pump
Pg. 9-10
Cleaning, Hygiene, and Care
Pg. 11-13
Button and Display Guide
Pg. 14
Ready To Pump
Pg. 15-16
Milk Storage
Pg. 17
Troubleshooting & Customer Care
Pg. 18-21
Find Your Fit & Technical Information
Pg. 21-23

4
IMPORTANT SAFETY INSTRUCTIONS
This is a single user product, use by more than one person can present
health risk and performance questions and will void the warranty.
WARNING! READ ALL INSTRUCTIONS BEFORE USING THIS PRODUCT.
When using this pump and other electrical products, basic safety precautions
should always be maintained, including the following:
DANGER:To reduce the risk of electrocution
•ALWAYS unplug electrical product immediately after use.
•DO NOT USE while bathing.
•DO NOT place or store this product where it can fall into a tub or sink.
•DO NOT place in or drop into water or other liquid.
•DO NOT reach for product if it has fallen into the water. Unplug
immediately
•NEVER immerse pump unit or AC adaptor in water or attempt to
sanitize in a microwave
WARNING: To reduce the risk of burns, electrocution, fire or injury to persons:
•Use this product only for its intended use as described in these
instructions.
•Breast pumps are personal care items for one user only.
•Danger of electrocution! Keep the device dry, never immerse in water
or other liquids. Do not run water over the pump
•Keep the power adaptor away from heated surfaces.
•Do not reach for product if it has fallen into water. Unplug immediately
•Do not use outdoors with AC adaptor, or operate where aerosol spray
products are being used, or oxygen is being administered.
•Close supervision is necessary when being used near children
•Do Not allow small children to play with the pump unit, accessories, AC
adaptor, etc. These parts may cause a choking or strangulation hazard.
Keep pump and all accessories out of REACH OF CHILDREN.
•DO NOT use attachments not recommended by the manufacture.
•Do NOT use this product if it is broken or any parts are missing.
•Do not use while bathing or showering.
•Never operate this product if it has a damaged cord or plug, if it has
been dropped or damaged or is any parts are broken or missing.
•Do not use while sleepy or drowsy
•Do not place product in direct sunlight
•Do not drop, hit, or insert any object into any opening or tubing

5
•Do not touch the product or parts with bare hands after boiling to avoid
scalds and burns.
SAVE THESE INSTRUCTIONS!
GENERAL SAFETY INSTRUCTIONS
WARNING! Read and understand all instructions. Failure to follow
these instructions and safety guidelines can lead to harm or injury from
the device and may also damage the pump and kit.
The warnings, cautions and instructions discussed in this instruction
manual cannot cover all possible conditions and situations that may
occur. It must be understood by the user that common sense and caution
area factor that cannot be built in this product but must be supplied by
the user.
•This is a single user product. Use by more than one person may present a health risk.
•Use the electric breast pump only for its intended use as described in this manual.
•You should not experience discomfort or pain when using your Crane breast pump.
Use the suction level and settings that are within your own comfort level. If you
experience discomfort or pain, stop using the device and contact your professional
lactation consultant, care provider or Crane representative.
•Do not use the electric breast pump while sleeping or overly drowsy.
•Supervision is required when electric breast pump is used in the vicinity of children.
•Unplug the AC adapter from wall socket outlet when the pump is not in use and store
out of reach of children.
•AC Adaptor charger included with the Crane Double Electric Breast Pump is 110-240V
50/60Hz and can be used worldwide, however, in some countries you may need to
use an outlet adaptor.
•Do not leave your Crane Double Electric Breast Pump unattended while plugged in.
•Do not operate the electric breast pump if it is damaged or showing signs of
excessive wear. This includes the plug and power cord too.
•Do not use 3rd party accessories, attachments or fittings with your Crane pump.
•Do not place the electric breast pump near any appliances generating a strong
magnetic field.
•Do not use near concentrated oxygen or pressurized gases
•Do not drive while pumping.
•Inspect all pump components before each use.
•Do not thaw frozen breast milk in a microwave or a pan of boiling water.
•Clean and sanitize all parts that come into contact with breast/breast milk prior to
first use.
•Wash all parts that come into contact with your breast/breast milk after each use.

6
•If you experience any pain or discomfort of the breast or nipple, stop using the breast
pump and consult your lactation consultant or physician immediately.
THIS PRODUCT IS INTENDED FOR PERSONAL USE ONLY
Introduction
Functions & Features
Your Crane breast pump has the following functions and features:
•Double sided pumping: Your pump includes everything you need for double
pumping. Pumping from both sides at once saves you time and supports
better milk supply.
•A fully closed system with anti-backflow.
•Ergonomic milk collection kit: Silicone 3D Cushions allow for a more
comfortable fit and help to apply gentle pressure, better suction and
massage action to stimulate lactation while pumping.
•2-Phase expression- Stimulation and Expression
•9 Adjustable suction levels
•Control in your hands: With a flexible range of modes, levels and dual
pumping options, the Crane double electric breast pump lets you find the
ideal pumping combination.
•Touch control: Easy use and & wipe clean controls
•30 min count-up timer: Time your current pumping session up to half an
hour.
•All parts are BPA Free.
•Portable, compact design: Gives you and baby more flexibility to pump
whether at home or on the go. Your Crane double electric breast pump
comes complete with a built in rechargeable li-ion polymer battery.

7

8
Parts

9
Other available parts
The Silicone 3D cushions fit around the nipple and come in a range of sizes, you’ll
find the most commonly used size in your Crane breast pump box. Your nipple
will expand while milk is being expressed. If you find the standard sized Silicone
3D cushion is too small or too large, other sizes are available from your Crane
retailer. See the back of the instructions for information on how to measure your
nipple for the correct sized cushion.

10
Assembling Your Crane Pump
MILK Collection Kit
(3D Cushion, Breast Shield, Diaphragm and Diaphragm Cap)
Insert the silicone 3D cushion into the breast shield
body. Ensure the edge of the 3D cushion
Is attached to the breast shield body.
Secure valve
Once the silicone 3D cushion is inserted
Into the breast shield body, gently push
Upwards on the valve to make sure it is
Securely attached to the inside body of
The breast shield.
Diaphragm and Cap
Carefully insert the diaphragm into the
top of the breast shield body. Make sure
the edge is flush and the seal is good.
Screw the cap on tightly to prevent
Any air from leaking.
Assemble the Bottle
Place the assembled breast shield body
onto the bottle. Screw the bottle onto
the breast shield body.
Indice
Altri manuali Crane Tiralatte