Daeil Fish Cooler DBI-030 Manuale utente

DBI - 030D
A
Q
U
A
R
I
U
M
C
O
O
A
Q
U
A
R
I
U
M
C
O
O
Distributed by: Extra Bright Lighting & Electric Co., Ltd.
Rm 1703, 40 Sha Tsui Road, Tsuen Wan
http://www.solarmax.com.hk
Power Supply: 220V 50Hz
IC Electronic Temperature Controller
Ozone Friendly Refrigerant (R-134a)

TABLE OF CONTENTS
1. SAFETY 1
1-1. Warning Icons 2
1-2. Data Lable 2
2. INTRODUCTION 3
3. RECEIVING AND INSPECTION 3
4. INSTALLATION 4
4-1. Installation to Aquarium (or Tank) 4
4-2. How to Connect Hose 4
5. INSTRUCTION FOR US 5
5-1. Start Up 5
6. MAINTENANCE
6-1. Operation To Be Carried Out Every 6 Months 6
Table 1 Chiller Speications 6
Figure 1 Electrical Digram 7
Figure 2 Electrical Digram 7
Figure 3 Part name for Chiller 8
Figure 4 Exploded View and Part Name 9
Figure 5 Exploded View and Part Name 10

- 1 -
1 SAFETY
The coolers are designed and built with safety as a prime
consideration; industry-accepted safety factors have been used in the
design. Each cooler is checked at the facotry for safety and operation.
All necessary adjustments are made before shipment.
Follow the maintenance schedules outlined in this manual for good
performance and safe operation. Maintenance should be done only by
qualified person with proper tools.
Carefully read the following safety rules before proceeding with
installation, operation or maintenance. The rules are essential to
ensure safe cooler operation. Failure to follow these rules void the
warranty or results in cooler damage or peronal injury.
1. Do not install or try to repair a cooler that has been damaged in
shipment. See RECEIVING AND INSPECTION for instructions.
2. Electricity has the potential to cause personal injury or equipment
damage. Before doing any work on the cooler, be sure the electrical
supply has been locked.
3. Do not operate the cooler at the temperature above the maximium
conditions (see table 1).
4. Always supply electrical power that complies with the voltage shown
on the data label.
5. Work in the refrigeration system must be done only by a competent
refrigeration mechanic.
6. Use only manufacturer’s genuine replacement parts. The
manufacturer bears no responsibility for hazrads casued by the use of
unauthorized parts.

- 2 -
1-1. Safety Instructions
The cooler data label contains identification information. If the data
label is missing or damaged, contact your local distributor and request
a replacement.

- 3 -
2. INTRODUCTION
Aquarium Fish Coolers use mechanical refrigerationto cool water in the aquarium.
See Table 1 for rated capacity and other cooler specifications.
Throughout this manual, the word "cooler" is used to refer to the Aquarium Fish
Coolers. To ensure continuing good performance and safe operation, everyone
who installs, users or maintains the cooler must read and carefully follow the
instruction in this manual.
3. RECEIVING AND INSPECTION
Inspect the cooler closely when it is received. Record any indication of damage on
the delivery receipt, especially if the cooler will not be immediately uncrated.
Obtain the delivery person's signed agreement to recorded damages to facilitate
future insurance claims.
Since the cooler is shipped F.O.B. Factory, the manufacturer's responsibility for the
shipment cases when the carrier signs the bill of lading.
If goods are received short or damaged condition, notify the carrier and insist on a
notation of the loss or damage across the face of the freight bill. Otherwise no
claim can be enforced against the carrier.
If concealed loss or damage is discovered, notify your carrier at once and request
an inspection. This is absolutely necessary. Unless you do this, the carrier will not
consider any claim for loss of damage. The carrier will make an inspection and
may grant a concealed damage notation. If you give the carrier a clear receipt for
the goods that have been damaged or lost in transit, you do so at your own risk
and expense.
The manufacturer is willing to assist you in collecting claims for loss or damage.
Willingness does not make the manufacturer responsible for collecting claims or
replacing material. Claim filling and processing is your responsibility.

Place the cooler in a ventilated place and away from sources of heat, taking care that the
evacuation holes, indispensable for taking in air, are not less than 30cm from any
obstacle. The chiller must have proper air ow to function correctly. DO NOT PLACE
INSIDE AQUARIUM STANDS THAT ARE ENCLOSED!
cooler
DBI-030 / DBI-050 DBA-075/DBA-150/DBA-200/DBM-250
- 4 -

- 5 -
INSTRUCTION FOR USE
25 °C
0.3 °C
25 0 25 0 25 0 26 0 26 0
25°C 26°C
5
* Troubleshooting Errer Messages Display Messages
27 0 27 0 27 0 20 0
20°C
27°C

- 6 -
490L
15/60
20kg12kg10kg
12.7mm
22kg 23kg 28kg
30/80 30/120 30/150
220V 50Hz
Ambient Temperature should be kept under 35°C
680L 980L
DBA-200DBI-030 DBI-050
1280L300L150L
1/20 Hp 1/15 Hp
1.85/2.641.85/2.64
Cooler Specifications

- 7 -
Figure 1. ELECTRIC WIRING DIAGRAM OF FISH COOLER
MODEL: DBI-030 / DBI-050
Figure 2. ELECTRIC WIRING DIAGRAM OF FISH COOLER
MODEL: DBA-075 / DBA-150 / DBA-200 / DBM-250
AC 220V 50Hz
AC 220V 50Hz
COOLER

A
Q
U
A
R
I
U
M
C
O
O
L
E
R
A
Q
U
A
R
I
U
M
C
O
O
L
E
R
- 8 -
25°C
Figure 3
Part Name for Fish Cooler
DBA-075 / DBA-150 / DBA-200
DBM-250
DBI-030 / DBI-050
Questo manuale è adatto per i seguenti modelli
5
Indice

















