Danfoss Link HC Manuale utente

Danfoss Link™ HC Hydronic Controller
Installation Guide
Danfoss Heating Solutions
MAKING MODERN LIVING POSSIBLE
Danfoss A/S
DK • 7100 Vejle
Phone +45 7488 8500
Fax +45 7488 8501
VIFZL15X © Danfoss 08/2010

3
VIFZL15X © Danfoss 08/2010
GB
DE
FR
DK
FI
NL
PL
CZ
Installation Guide Danfoss Link™ HC
Installation Guide
Installationsanleitung
Guide d’installation
Installationsmanual
Asennusohje
Installatiehandleiding
Instrukcja instalacji
Instalační příručka

4VIFZL15X © Danfoss 08/2010
Installation Guide Danfoss Link™ HC
Introduction ............................................................................5
Mounting
1: Mounting on wall ........................................................5
2: Mounting on DIN-rail.................................................... 5
Connections
1: Connecting actuators ....................................................6
2: Connecting pump and boiler controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3: Connections for Away Function...........................................6
4: Connections for Heating & Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
5: Power supply ........................................................... 7
6: Wiring diagram ......................................................... 7
7: External antenna . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Configuration
1: Adding Danfoss Link™ HC to the system. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2: Configure Danfoss Link™ HC............................................. 8
2a: Configure outputs.................................................. 9
2b: Configure inputs ....................................................9
3: Add an output to a room .................................................9
4: Configure a room .......................................................10
5: Remove an output ......................................................11
6: Factory reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Trouble shooting.........................................................................13
Technical specifications ................................................................. 13
Disposal instructions .................................................................... 13
Index

5
VIFZL15X © Danfoss 08/2010
Installation Guide Danfoss Link™ HC
GB
Danfoss Link™ is a wireless control system for a variety of heating systems.
The Danfoss Link™ HC (Hydronic Controller) is a part of this system allowing wireless control of
manifolds for water based floor heating/cooling.
Inputs:
Not in use
Away Function (external ON/OFF switch)
Heating/Cooling (external ON/OFF switch)
Front
cover
release
External
Antenna
Output LEDs
Install / Link TestOutput connections
Pump relay
Boiler relay
Introduction
The Danfoss Link™ HC should always be mounted in an horizontal upright position.
1: Mounting on wall
1. Remove front and side covers and mount with screws and wall plugs.
2: Mounting on DIN-rail
1. Mount DIN-rail parts. 2. Click on DIN-rail. 3. Release from DIN-rail.
Mounting

6VIFZL15X © Danfoss 08/2010
Installation Guide Danfoss Link™ HC
Make sure that all connections to the Danfoss Link™ HC are completed, before connecting to a 230 V
power supply.
1: Connecting actuators (24 V)
If NC (normally closed) actuators are installed for ON/OFF regulation, no further actuator output con-
figuration is needed.
1. Connect actuator wires to an output. 2. Fix the cable.
2: Connecting pump and boiler controls
The relays for pump and boiler are potential free contacts and can thus NOT be used as direct power
supply. Max. load is 230 V, 8 (2) A.
1. Connect wires for pump and boiler controls to their
respective output.
2. Fix the cable.
3: Connections for Away Function
The Away Function ensures a set room temperature fixed at 15°C for all Room Thermostats,
but it can be changed with the Danfoss Link™ CC.
1. Connect an external ON/OFF switch to the termi-
nals for Away Function. When this switch is closed
(ON) the system will override all room thermostat
set points and change it to 15°C.
2. Fix the cable.
Connections

7
VIFZL15X © Danfoss 08/2010
Installation Guide Danfoss Link™ HC
GB
4: Connections for Heating & Cooling
When the system is in cooling mode the actuator output will be activated (ON for NC
actuators / OFF for NO actuators) when the temperature in a room exceeds the set point.
When the system is in cooling mode an independent dew-point alarm function should be installed.
1. Connect an external ON/OFF switch to the
terminals for Heating & Cooling. When this
switch is closed (ON) the system will switch
from heating to cooling.
2. Fix the cable.
5: Power supply
When all actuators, pump and boiler controls and other inputs are installed, connect
the supply plug to a 230 V power supply.
If the power supply plug is removed during installation, make sure that the connection is made ac-
cording to existing law/legislation.
6: Wiring diagram
LN
9 10876 54321
Actuator outputsRelays
Input
230 V~
50 Hz
External
antenna
LN
Away
Heating / Cooling
max. 3 m
7: External antenne
The external antenna is installed as diverter when there is no transmission possible through a large
building, heavy construction or metal barrier, e.g. if the Danfoss Link™ HC is located in a metal cabinet/
box
1. Remove the plastic cover from the antenna con-
nection.
2. Connect the external antenna and place it on the
other side of the transmission barrier.
Connections

8VIFZL15X © Danfoss 08/2010
Installation Guide Danfoss Link™ HC
1: Adding Danfoss Link™ HC to the system
Adding Danfoss Link™ HC to a system is made from the Danfoss Link™ CC Central Controller. For
further information, see the Danfoss Link™ CC instruction manual: Configuration 7: Adding service
devices.
1. Select “Rooms and Devices”. 2. Select “Add Service Device”. 3. Select “Begin Registration”.
4. Select Install / Link Test on HC. 5. If wanted, edit room name with
the letter keys.
6. End with pressing “OK/Return”.
2: Configure Danfoss Link™ HC
Configuration Danfoss Link™ HC to a system is made from the Danfoss Link™ CC Central Controller.
For further information, see the Danfoss Link™ CC instruction manual: Configuration 7: Adding service
devices.
1. Select “Rooms and Devices”. 2. Select “Manage Devices”. 3. Select device to configure.
Configuration

9
VIFZL15X © Danfoss 08/2010
Installation Guide Danfoss Link™ HC
GB
2a: Configure outputs
1. Select “Set up Relays”. 2. Select “Boiler Relay” or “Pump
Relay”.
3. Choose your settings and press
“OK/Return”.
2b: Configure inputs
1. Select “Setup Inputs”. 2. Select input to configure. 3. Choose your settings and press
“OK/Return”.
3: Add an output to a room
Configuration Danfoss Link™ HC to a system is made from the Danfoss Link™ CC Central Controller.
For further information, see the Danfoss Link™ CC instruction manual: Configuration 7: Adding service
devices.
1. Select “Room devices”. 2. Select “Add a device”. 3. If Danfoss Link™ HC is installed,
a selection screen appears.
Configuration

10 VIFZL15X © Danfoss 08/2010
Installation Guide Danfoss Link™ HC
4. If more devices are installed,
select a device.
5. Select output. Only available
outputs are selectable.
6. Select heating emitter and press
“Actuator Settings”.
7. Select actuator type and press
“OK/Return”.
4: Configure a room
• Forecasting method:
by activation of the forecast
method, the system will automati-
cally predict the heating start-up
time necessary to reach desired
room temperature at desired time.
• Regulation type:
only in connection with electrical
heating systems.
1. Select “Heating regulation”. 2. Select type of regulation.
Configuration

11
VIFZL15X © Danfoss 08/2010
Installation Guide Danfoss Link™ HC
GB
5: Remove an output
1. Select “Rooms and Devices”. 2. Select “Manage Devices”. 3. Select an existing room.
4. Select “Room devices”. 5. Select “Remove a device”. 6. Select “Remove an output”.
7. Select “Yes, remove an output
now”.
Configuration
Altri manuali per Link HC
2
Indice
Lingue:
Altri manuali Danfoss Stufa

Danfoss
Danfoss Akva Vita TDP-F Manuale utente

Danfoss
Danfoss Termix VVX Compact 28/18 - 7 BS-HC Series Manuale utente

Danfoss
Danfoss AME 335 Manuale utente

Danfoss
Danfoss VM2 Manuale utente

Danfoss
Danfoss InLine Manuale utente

Danfoss
Danfoss Akva Lux II VXe Manuale utente

Danfoss
Danfoss RA 2000 Manuale utente

Danfoss
Danfoss Termix HD MIX Compact 28 Manuale utente
Manuali Stufa popolari di altre marche

Empire Heating Systems
Empire Heating Systems WCC65 Manuale utente

Wetekom
Wetekom 92 86 43 Manuale utente

Desa
Desa SPC170-F Manuale utente

Watlow
Watlow Watrod Electric Tubular Heaters Manuale utente

Haverland
Haverland ECO-DRY GPS Series Manuale elenco delle parti

Stelpro
Stelpro ASILVC2060 Series Manuale utente