Daniamant RL1 Manuale utente

RL1 Liferaft lights & RB2 Battery pack
also applies to RL1 (RFD/DSB) & RB2 (RFD/DSB)
Installation and Maintenance Instructions
Description
RL1 The RL1 is an internal light for liferafts to provide adequate light for reading inside a covered raft,
for a minimum of 12 hours. The unit is fully sealed and watertight, and comprises a plastic dome
and incandescent lamp. A cable with moulded plug is provided to connect to the socket of a RB2
battery pack.
RB2 Each battery pack comprises a single lithium cell in a sealed moulded housing including a switch;
this permits both automatic and manual operation. The battery is protected against damaging
currents and short circuits by a fuse.
58-7010-PAT Issue 11 (C6495)

Installation
Light
The base of the RL1 has two fixing slots. The unit can be attached to the raft by:
– Being stitched to raft fabric, then mounted by adhesive inside the apex of the canopy.
– By a fixing plate, as shown on Page 3.
Battery leads should be stitched into a seam during raft manufacture. The lead length is configured to
suit the raft requirements.
Battery
The battery pack is a power source for one light only. The battery is installed in a pocket or restrained
by straps in the raft, where it is easily visible for manual operation. If the instructions on the battery label
are obscured, they should be repeated elsewhere on the raft. For automatic operation the pull toggle
should be fixed by its cord to the side of the raft opposite the battery so that it is pulled out when the raft
inflates.
Operation
When installed for automatic operation, the light will illuminate when the raft is inflated. A slide switch on
the side of the battery pack may be pressed up and down to turn the light on or off. This permits manual
operation of the lamp, as often as necessary.
Maintenance
Routine service and battery replacement
RL1 and RB2 units are maintenance free, but the following checks should be made at each service of
the liferaft:
1. Check date on battery pack. Battery packs must be replaced not more than 5 years after date of
manufacture; consequently, if the battery expiry date is earlier than the next liferaft service then
the battery should be replaced (Standard replacement part 71-C200).
2. Inspect light and batteries for signs of damage or corrosion. Lightly grease battery connector ‘O’
ring with silicone grease and replace connector. If damage or corrosion visible the unit is to be
replaced.
3. Remove pull toggle from RB2 battery pack – light should illuminate immediately. If light fails to
operate, go to step 4. If light operates, replace toggle in battery pack; test is complete.
4. 4. If light fails to operate, replace battery pack with a checked unit and retest from step 3. If light
continues to malfunction, replace light and cable assembly with a checked unit.
After Use
Battery pack, light and cable assembly must be changed after use.
Safety
RB2 battery packs contain a Lithium cell. This must be handled correctly:
– Do not dismantle battery pack
– Do not make any external electrical connection
– Do not recharge
– Do not incinerate
– Store between –30ºC and +65ºC
Health and Safety information
Daniamant lithium-powered marine safety light systems have a design life of 5 years. The batteries are
hermetically sealed pressurised primary Lithium/Sulphur Dioxide cells, and as supplied are electrically
protected by diodes and a fuse, and are environmentally protected by a moulded plastic housing. In this
condition the units pose no definable hazard to health.
2

Battery disposal
Dispose of used batteries in accordance with local regulations. This should be done through an approved
environmental disposal agent.
Light and battery pack
Method of attaching light
Suggested attachment points to liferaft (alter-
native positions may be used)
3

Product Disposal Instructions
Daniamant’s Survivor Location Lights contain batteries as well as electrical and
electronic components, and must therefore be segregated from the domestic
waste stream and recycled. Disposing of this product correctly will help save
valuable resources and prevent any potential negative effects on human health
and the environment, which could otherwise arise from inappropriate waste han-
dling. Daniamant’s lights are marked with the symbol below which conveys that
this waste must be treated separately from household waste.
To ensure compliance with the WEEE and Battery Regulations, the Survivor Lo-
cation Lights placed on the market in the UK or Denmark should be returned to
Daniamant in the UK or Denmark, or deposited in your nearest WEEE Designated Collection Facility,
operated by your Local Authority.
4

RL4 Liferaft light & RB2 Battery pack
also applies to RL4 (RFD/DSB) & RB2 (RFD/DSB)
Installation and Maintenance Instructions
Description
RL4 The RL4 is a high intensity flashing light for mounting externally on liferafts. The unit is fully sealed
and watertight, and comprises a plastic dome, incandescent lamp and electronic circuit. Two
cables with moulded plugs are provided to connect to the sockets of two RB2 battery packs. The
dome is sealed by a neoprene ‘O’ ring.
RB2 Each battery pack comprises a single lithium cell in a sealed moulded housing including a switch;
this permits both automatic and manual operation. The battery is protected against damaging
currents and short circuits by a fuse. Operational life is 12 hours minimum.

Installation
Light
The base of the RL4 has two fixing slots. The unit can be attached to the raft by:
– Being stitched to raft fabric, then mounted by adhesive at the apex of the canopy.
– By a fixing plate, as shown in the attached drawing.
Battery leads should be stitched into a seam during raft manufacture. The lead length is configured to
suit the raft requirements.
Battery
Two battery packs are required as the power source for one flashing light. Note: the battery packs are
connected in series through the electronics unit. The batteries are installed in a pocket or restrained by
elastic straps under the raft canopy, where they are easily visible for manual operation. Battery packs
must be installed at least 50mm apart to prevent magnetic interaction. If the instructions on the battery
label are obscured, they should be repeated elsewhere on the raft. For automatic operation both pull
toggles should be fixed by their cords to the side of the raft opposite the batteries so that they are pulled
out when the raft inflates.
Operation
When installed for automatic operation, the light will illuminate and flash when the raft is inflated. Slide
switches on the sides of the battery packs may be pressed down and up to turn the light on or off; both
switches must be on for the lamp to operate. This permits manual operation of the lamp, as often as
necessary.
Maintenance
Routine service and battery replacement
RL4 and RB2 units are maintenance free, but the following checks should be made at each service of
the liferaft:
1. Check date on battery pack. Battery packs must be replaced not more than 5 years after date of
manufacture; consequently, if the battery expiry date is earlier than the next liferaft service then
the battery should be replaced (Standard replacement part 71-C200).
2. Inspect light and batteries for signs of damage or corrosion. Lightly grease battery connector ‘O’
ring with silicone grease and replace connector. If damage or corrosion visible the unit is to be
replaced.
3. Remove pull toggles from RB2 battery packs – light should illuminate and flash immediately. If light
fails to operate, go to step 4. If light operates, replace toggles in battery packs; test is complete.
4. If light fails to operate, replace battery packs with checked units and retest from step 3. If light
continues to malfunction, replace light and cable assembly with a checked unit.
After Use
Both battery packs, light and cable assembly must be changed after use.
Battery disposal
Dispose of used batteries in accordance with local regulations. This should be done through an approved
environmental disposal agent. See page 4.
Safety
RB2 battery packs contain a Lithium cell. This must be handled correctly:
– Do not dismantle battery pack
– Do not make any external electrical connection
– Do not recharge
– Do not incinerate
– Store between –30ºC and +65ºC

Health and Safety information
Daniamant lithium-powered marine safety light systems have a design life of 5 years. The batteries are
hermetically sealed pressurised primary Lithium/Sulphur Dioxide cells, and as supplied are electrically
protected by diodes and a fuse, and are environmentally protected by a moulded plastic housing. In this
condition the units pose no definable hazard to health.
Information on the composition and behaviour of these products is contained in the Material Safety Data
Sheet.
Light and battery pack
Method of attaching light
The fixing plate is a flat disc with pro-
truding tabs on one face which clip into
the base of the lampholder. The fixing
plate requires two holes 6mm diameter
at 30mm centres in the liferaft material to
provide clearance for the clip tabs. Suit-
able for fixing to material of maximum
thickness 3mm
Suggested attachment points to liferaft
(alternative positions may be used)

Product Disposal Instructions
Daniamant’s Survivor Location Lights contain batteries as well as electrical and
electronic components, and must therefore be segregated from the domestic
waste stream and recycled. Disposing of this product correctly will help save
valuable resources and prevent any potential negative effects on human health
and the environment, which could otherwise arise from inappropriate waste han-
dling. Daniamant’s lights are marked with the symbol below which conveys that
this waste must be treated separately from household waste.
To ensure compliance with the WEEE and Battery Regulations, the Survivor Lo-
cation Lights placed on the market in the UK or Denmark should be returned to
Daniamant in the UK or Denmark, or deposited in your nearest WEEE Designated Collection Facility,
operated by your Local Authority.
Learn more about marine signaling devices & safety lights we have.
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Daniamant Attrezzatura di illuminazione

Daniamant
Daniamant Dan WR3-2 Manuale utente

Daniamant
Daniamant ODEO FLARE Manuale operativo

Daniamant
Daniamant SL-450 Manuale utente

Daniamant
Daniamant L7A Manuale utente

Daniamant
Daniamant Dan W3-1 Manuale utente

Daniamant
Daniamant L90 Manuale utente

Daniamant
Daniamant Dan WR3 Manuale utente

Daniamant
Daniamant Dan WL3 Manuale utente

Daniamant
Daniamant Dan M3 Manuale utente

Daniamant
Daniamant SL-400 Manuale utente