Dantel B15-00459-02 Manuale utente

CAUTION
Install or remove modules from the shelf only when the power is off.
If you install a module in the shelf with the power on, the internal
circuitry may suffer damage and the product warranty will be void.
Remove and install circuit boards only in a static-safe environment
(use antistatic wrist straps, smocks, footwear, etc.).
Keep circuit boards in their antistatic bags when they are not in use.
Do not ship or store circuit boards near strong electrostatic, electromag-
netic, magnetic, or radioactive fields.
For more complete information on electrostatic discharge safety
precautions, refer to BellcoreTM Technical Reference #TR-NWT-000870.
Copyright 1999 by Dantel, Inc. • Dantel is a registered trademark of Dantel, Inc. • ISO 9001 Registered
Printed in the U.S.A.
INSTALLATION&OPERATION MANUAL
05725-02-0499<90-00201>
B18-05725-02
REMOTE E2A ALARM SHELF,
WITH 64-KILOBIT OUTPUT, USING
46600-38 FIRMWARE
64 DISCRETE INPUTS, 16
CONTROLS, NOSERIAL
About this Practice:
This is a new document.
Issue date: April 1999
Reissued Practices: Updated and
new content can be identified by a
banner in the right margin.
UPDATED
Table of Contents
Ordering Information ............................................................................ 2
General Description ............................................................................... 2
Installation ............................................................................................ 5
Turn-Up Procedure.............................................................................. 29
Support Documentation ....................................................................... 41
Warranty ............................................................................................. 42
xmt out
loop
mon
4003C
line amplifier
xmt
in
mon
tellabs
rcv in
mon
rcv out
mon
814003C
xmt
rcv
46009-0X
32 POINT
TRANSMITTER
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
A
B
C
D
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
A
B
C
D
A1 A2
RST ACK
A1
ON
XMT
DATA
RCV
DATA
46009-0X
32 POINT
TRANSMITTER
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
A
B
C
D
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
A
B
C
D
A1 A2
RST ACK
A1
ON
XMT
DATA
RCV
DATA
46020-XX
MULTI-ALARM
RESET
46033-XX
E-SYS
ADAPTER
XMT RCV
46105-XX
DUAL VF
RCV
MON DROP
XMT
RCV
XMT
CH 1
CH 2
MON DROP
46019-11
SUMMARY
LEVEL A
LEVEL B
LEVEL D
EXIST
ALARM
C/O NEW
ON
OFF ACK
LEVEL C
48001-XX
FUSE MODULE
123
456
789
10 11 12 13
12 7
8
9
10 11 12
46009-0X REV__ 46009-0X REV__ 46020-XX REV__ 46033-XX REV__ 46105-XX REV__ 46019-11 REV__ 48001-XX REV__
XMT DATA
DATA
XMT
CARRIER TEST
NORMAL
XMT
RCV
SYNC
RCV LVL
GND
XMT
RCV
SYNC
RCV LVL
GND
EXIST
ALARM
C/O NEW
ON
OFF ACK
EXIST
ALARM
C/O NEW
ALL
ON
OFF ACK
EXIST
ALARM
C/O NEW
ON
OFF ACK
ACK
COMM
RELAY
ALARM
46028-XX
CONTROL POINT
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
RXD
TXD
5
46028-XX REV__

PAGE 2 05725-02-0499<90-00201>
ORDERING INFORMATION
NOTE: This section lists the different options available for this product. To order any of the available
options, contact Dantel Inside Sales through our toll-free number, 1-800-432-6835.
OPTION NUMBER FEATURES
B18-05725-02 64 discrete alarms, 16 control points, terminal port for access, E2A output, 64 KB digital
output, cross-connect block and four 25-foot cables
GENERAL DESCRIPTION
T
he 05725 Remote E2A shelf is a 12-position 460 Alarm and
Control System (ACS) shelf. This shelf collects discrete alarm
data from central office communications equipment. The alarm
data is processed, concentrated, and converted to E2A protocol for
transmission to the host computer at the Alarm Center. For a
functional schematic of this shelf, refer to sheet 2 of 3 of the
B18-05725-XX drawing that accompanies this Application Manual.
The -02 option is equipped with a 46105 Dual VF 64-kilobit Chan-
nel Module. The output of this shelf is a digital signal that can be
transmitted over a 56K or 64K digital service channel.
MODULES
This shelf, like many Dantel shelves is made up of separate plug-
in modules that are factory-wired together to accomplish a task.
The modules used in the 05725-02 shelf are described below and
shown in Fig. 1.
Multiple Alarm Transmitters (MATs) - slots 1-2
Each MAT:
♦Reports the alarm status for up to 32 independent discrete
alarm inputs
♦Provides LEDs to indicate active alarms.
NOTE: Slots 3 and 4 are wired for MATs only and not equipped.
Control Point Module (CPM) - slot 5
The CPM provides 16 discrete (independent) relays controllable by
the MAP. Commands can be entered from the Printer Port of the
MAP using a dumb terminal (refer to 46020-38 manual), or by the
Alarm Center. Any of the 16 control points can be turned on or off
to control a particular piece of equipment.

05725-02-0499<90-00201> PAGE 3
Multiple Alarm Combiner (MAC) - slot 6
Slot 6 is wired only and not equipped.
Multiple Alarm Processor (MAP) - slot 7
The MAP is the center of the Dantel system. The MAP:
♦Polls (interrogates) remote alarm reporting equipment
♦Operates control points
♦Reports alarm status to the Alarm Monitoring Center (FMAC)
The MAP uses three ports to receive and transmit information:
♦The Data Port connects the MAP to the Control Point Module
(CPM) and Multi Alarm Transmitters (MATs) .
♦The Printer Port, (also called the Craft, Configuration, or Inter-
face Port), is used for local monitoring and configuring of the
MAP. A serial printer can be connected here to obtain a
hardcopy printout of the alarm information.
♦The Master Port is used to report the alarm information to the
alarm center through the E-System Adapter.
The Master Port provides mounting for the RS-232 subassem-
bly.
E-System Adapter (ESA) - slot 8
The ESA provides an interface between the MAP(s) and the TNC.
It:
♦Takes the DCP protocol from the MAP and converts it to E2A
♦Provides mounting for a 202 Tone Modem.
It then sends that information to the Alarm Center.
Tellabs 4003C Line Amplifier - slot 9
The 4003C Line Amplifier with Loopback provides:
♦Switch-selectable level control.
♦Equalization.
♦Impedance matching in transmit and receive channels.
♦Tone-activated or dc-activated equal-level loopback of the facil-
ity.
Dual VF 64-Kilobit Channel (64KB) - slot 10
The 64KB interfaces analog voice or data equipment to a
64-kilobit digital service channel equipment. The module has two
channels which operate independently or interconnected in bridge
configuration.
GENERAL DESCRIPTION

PAGE 4 05725-02-0499<90-00201>
GENERAL DESCRIPTION
Summary Alarm Module (SAM) - slot 11
This module provides a means to control an audible and/or visual
alarm device for four alarm levels (A,B, C, and D). Wired to, and
controlled by, the MAP in slot 7, the SAM provides four indepen-
dent form C relays.
Fuse Module - slot 12
The B11-48001-01 Fuse Module provides 13 GMT indicating-type
fuse circuits and a failure alarm circuit for fusing 400-type mod-
ules in an equipment shelf. The module fits into any 400-type or
similar equipment housing and operates on -21 to -56 VDC input
power. The front panel includes 13 indicating-type GMT fuses and
an alarm LED.
This application uses the Fuse Modules redundant inputs. Con-
necting one power supply as Source A, and a second power supply
as Source B parallels both supplies. Refer to Fig. 2.
FIG. 1 - 05725-02 SHELF FRONT VIEW
xmt out
loop
mon
4003C
line amplifier
xmt
in
mon
tellabs
rcv in
mon
rcv out
mon
814003C
xmt
rcv
46009-0X
32 POINT
TRANSMITTER
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
A
B
C
D
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
A
B
C
D
A1 A2
RST ACK
A1
ON
XMT
DATA
RCV
DATA
46009-0X
32 POINT
TRANSMITTER
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
A
B
C
D
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
A
B
C
D
A1 A2
RST ACK
A1
ON
XMT
DATA
RCV
DATA
46020-XX
MULTI-ALARM
RESET
46033-XX
E-SYS
ADAPTER
XMT RCV
46105-XX
DUAL VF
RCV
MON DROP
XMT
RCV
XMT
CH 1
CH 2
MON DROP
46019-11
SUMMARY
LEVEL A
LEVEL B
LEVEL D
EXIST
ALARM
C/O NEW
ON
OFF ACK
LEVEL C
48001-XX
FUSE MODULE
123
456
789
10 11 12 13
12 7
8
9
10 11 12
46009-0X REV__ 46009-0X REV__ 46020-XX REV__ 46033-XX REV__ 46105-XX REV__ 46019-11 REV__ 48001-XX REV__
XMT DATA
DATA
XMT
CARRIER TEST
NORMAL
XMT
RCV
SYNC
RCV LVL
GND
XMT
RCV
SYNC
RCV LVL
GND
EXIST
ALARM
C/O NEW
ON
OFF ACK
EXIST
ALARM
C/O NEW
ALL
ON
OFF ACK
EXIST
ALARM
C/O NEW
ON
OFF ACK
ACK
COMM
RELAY
ALARM
46028-XX
CONTROL POINT
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
RXD
TXD
5
46028-XX REV__
64 discrete alarm
points (32 per
card). Note that
the cards are not
interchangeable
without changing
addresses.
16 control
points
Central
processor
and RS-232
subassembly
E-System
Adapter and
202 Tone
Modem
4-wire
interface and
loopback unit
64 kilobit unit
Visual alarm
indicator
Fuse panel

05725-02-0499<90-00201> PAGE 5
This section consists of three parts:
1. Equipment Mounting
2. Wiring
3. Switch and Strap Settings
46009 Multiple Alarm Transmitter
46028 Control Point Module
46020-38 Multiple Alarm Processor with Firmware
46029 RS-232 Current Loop Interface Subassembly
46033 E-System Adapter
49013 202 Tone Modem Subassembly
Tellabs 4003C
46105 Dual VF 64-kilobit Channel
46019 Summary Alarm Module
48001 Fuse Module
4. Summary of Switch Settings
EQUIPMENT MOUNTING
Tools Required:
♦Ohmmeter
♦Phillips screwdriver
♦7/16" Nutdriver or socket wrench
♦(TMS) Transmission measuring Set
Visually inspect shelf for obvious damage.
Use ohmmeter to check for a short across the power input at A
and B (-DC) and (GND) at the left end of the rear of the shelf (refer
to Fig. 2).
TMS is used to verify the levels at the output of the 46033
E-System Adapter and the 4003C Line Amplifier.
INSTALLATION

PAGE 6 05725-02-0499<90-00201>
FIG. 2 - REAR VIEW OF 05725 SHELF
With a Phillips screwdriver, mount the shelf in an equipment rack
using the screws and lockwashers supplied in a bag attached to
the side of the shelf.
Mounting hardware is supplied in a bag attached to the side of the
shelf.
Refer to Figure 3.
INSTALLATION
FA
FB
C
B
1
25
116
TB 116
TB
15 30 15 30
C1
C2
C3
C4
TB
1
2
3
4
5
6
7
8
9
10
A
B
E
F
C5 C6 C7 C8
C1
C2
C3
C4
PANEL D PANEL C PANEL B PANEL A
-DC
GND 111 1
1
25
50 26
XMIT REC
LINE (ZAET Circuit)
LIST
13
CABLS
,
M
/
F
CONNECTOR
25
FT
LENGTH
PART
NUMBER
26-49020-25
LIST 11
TS 1 BLOCK
PART NUMBER
25-00710-00
(A) (B) (C) (D)
BOTTOM
FRONT
Alarm
Points
1-32
Alarm
Points
32-64
(65 to
96 not
used)
Alarm
Points
97-128
(not
used)
Control
Points
1-16
-BATTERY
(Source A)
RTTR
-BATTERY
(Source B)
GND
Connect to 64kb Channel
Connect to 64kb Channel
(if repeater)

05725-02-0499<90-00201> PAGE 7
FIG.3-MOUNTING CONFIGURATION,41075400-TYPE MOUNTING
INSTALLATION
1. Facing the frame rail, place the equipment shelf in the rack in the
desired location. Secure with three Phillips-head screws and
lockwashers - two on the right side, top and bottom, and one on the
lower left side.
2. Install one ESD stud, with lockwasher, in the upper left location.
3. Secure all fasteners tightly, ensuring proper grounding between ESD
stud and frame rail.
4. Place ESD label next to the ESD stud.
5. From the rear of the bay, install the other ESD stud and lockwasher
into the frame rail next to the equipment shelf. Secure tightly, ensur-
ing proper grounding of the ESD stud. Place ESD label next to the
ESD stud.
WIRING
Wire the 05725 Remote E2A Alarm Shelf to external equipment as
required. Use the B18-05725-XX Block and Level Drawing as a
reference for making connections to Dantel equipment.
Refer to interconnect wiring diagram Fig 4. This will help under-
stand and read the circuit diagrams.
64kb Channel
♦Connect to C1-B for terminal application.
♦Connect to C1-B and C2-B for repeater application.

PAGE 8 05725-02-0499<90-00201>
INSTALLATION
FIG.4- 05725INTERCONNECT DIAGRAM
8A
8B
8C
8D
4003c
TELLABS
7A
7B
7C
7D
6A
6B
6C
6D
E-SYS
ADAPTER
5E
5F
4B
4C
MAP MAC
Optional TB-A TB-A
2A
2B
2C
2D
3A
3B
3C
3D
CPM
TB-A
5B
5D
5A
5C 29
30
MAT MAT
WIRING ADDED WHEN
PANEL IS NOT EQUIPPED
WITH A MAC CARD
12345678910
A
B
C
D
E
F
TB-A
TERMINAL STRIP
BACKPLANE IN PANEL A
INDICATES WIRE STRAPS
TB-D
GND
TB-A TB-A TB-A TB-A TB-A
9A
9B
9C
9D
05725-02
C1-B
C1-A
64 KB Channel
64 KB Channel
11
3
12
4
14
6
9
1
11
3
12
4
14
6
9
1
46105
64kB

05725-02-0499<90-00201> PAGE 9
STRAP AND SWITCH SETTINGS
46009 Multiple Alarm Transmitter (MAT)
Refer to Fig. 5 and Table A.
FIG. 5 - 46009 MAT SWITCH AND STRAP LOCATIONS
INSTALLATION
1 2 3 4
1 2 3 4 5 6 7 8
1 2
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
BOTTOM EDGE
*S5 S4 S3
* Shown for display 5 points 1-32.
TOP EDGE
B A
S6
S301

PAGE 10 05725-02-0499<90-00201>
TABLE A - 46009 MAT SWITCH AND STRAP OPTIONS
INSTALLATION
SWITCH
SW5
Slot 1 **
Slot 2 ***
SW4
SW3
SW6
SW301
POSITION
12345678
01101111
01101101
11010001
01111111
1111----
01------
NOTE: A 1 indicates that the switch is up (up = OFF). A 0
indicates that the switch is down (down = ON).
** DCM addresses 17/18 (display 5, bits 1-32)
*** DCM addresses 19/20 (display 5, bits 33-63)
NOTE: The MATs in slots 1 and 2 are not interchangeable without changing
the address on switch 5 first.
46028 Control Point Module (CPM)
Refer to Fig. 6 and Table B.
FIG. 6 - 46028 CPM SWITCH AND STRAP LOCATIONS
113
1
4
J5
J4
SUBASSEMBLY
MOUNTING
AREA
OFF
18
OFF
18
S1 S2
UP=OFF
DOWN=ON
A
NORM
REV
S3
B
Bottom Edge View
SWITCH 1 SWITCH 2
UP = OFF
DOWN = ON
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
Indice
Altri manuali Dantel Sistema di sicurezza

Dantel
Dantel A23-41073-00 Manuale utente

Dantel
Dantel 46022-30 Manuale utente

Dantel
Dantel 46022-12 Manuale utente

Dantel
Dantel 05202 Manuale utente

Dantel
Dantel 46022-20 Manuale utente

Dantel
Dantel A18-05791 Series Manuale utente

Dantel
Dantel RemoteMaster 46132-41 Manuale utente

Dantel
Dantel B23-41071 Manuale utente

Dantel
Dantel 46131 Manuale utente

Dantel
Dantel B18-05725-03 Manuale utente
Manuali Sistema di sicurezza popolari di altre marche

EDM
EDM Solution 6+6 Wireless-AE Manuale utente

Highway Safety Group
Highway Safety Group EA401 Manuale utente

Siren
Siren LED GSM Manuale utente

Detection Systems
Detection Systems 7090i Istruzioni per il montaggio

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Manuale utente

Siemens
Siemens FDM273 Manuale utente














