OWNER/INSTALLATION MANUAL
HEALTH AND SAFETY WARNING
This product contains electrical and rotational
equipment. ONLY competent trained people
should work on is device, and must be
isolated electrically before removing access
panels.
This appliance can be used by children from
8 years and above and persons wi reduced
physical, sensory or mental capabilities or
lack of experience and knowledge if ey
have been given supervision or instruction
concerning use of e appliance in a safe way
and understand e hazards involved. Children
should not play wi e appliance. Cleaning
and user maintenance shall not be made by
children wiout supervision.
HEALTH AND SAFETY WARNING

3
1007332 ISSUE 5
HEALTH AND SAFETY WARNING ���������������������������2
1�0 INTRODUCTION ��������������������������������������������������4
1�1 FOREWORD�����������������������������������������������������4
1�2 WARNINGS ������������������������������������������������������4
2�0 ABOUT YOUR HEAT PUMP �������������������������������8
2�1 TRANSPORTATION ����������������������������������������8
2�2 ACCESSORIES�������������������������������������������������8
2�3 OPTIONAL ACCESSORIES�����������������������������9
2�4 FEATURES������������������������������������������������������10
2�5 OPERATING CONDITIONS AND RANGE ���10
2�6 OPERATING MODES ������������������������������������10
3�0 INSTALLATION ��������������������������������������������������11
3�1 POSITIONING AND AIRFLOW���������������������11
3�2 REFRIGERANT TYPE AND INSTALLED
LOCATION�������������������������������������������������������������14
3�3 POOL WATER CIRCUIT���������������������������������15
3�4 PLUMBING�����������������������������������������������������16
3�5 INITIAL CHECKS �������������������������������������������16
3�6 ELECTROLYTIC CORROSION IN SWIMMING
POOLS�������������������������������������������������������������������17
3�7 ELECTRIC WIRING AND SUPPLY ���������������17
3�8 CONNECTING THE HEAT PUMP TO THE
POWER SUPPLY ��������������������������������������������������18
3�9 POOL PUMP SYNCHRONISATION
TERMINALS P1 AND P2�������������������������������������19
3�10 INSTALLING THE OPTIONAL REMOTE
CONTROLLER ������������������������������������������������������20
4�0 USING YOUR HEAT PUMP�������������������������������22
4�1 THE KEY PAD ������������������������������������������������22
4�2 OPERATING INSTRUCTIONS�����������������������23
4�3 USING THE APP��������������������������������������������24
4�4 USING THE OPTIONAL REMOTE
CONTROLLER ������������������������������������������������������30
4�5 THE KEY PAD ������������������������������������������������30
4�6 OPERATING INSTRUCTIONS�����������������������31
5�0 TESTING�������������������������������������������������������������32
5�1 HEAT PUMP MALFUNCTION ����������������������32
5�2 PROTECTION CODES ����������������������������������33
5�3 FAULT CODES������������������������������������������������34
6�0 MAINTENANCE �������������������������������������������������35
7�0 TROUBLE SHOOTING COMMON FAULTS �����35
8�0 DATASHEETS �����������������������������������������������������36
9�0 DIMENSIONS�����������������������������������������������������38
9�1 DIMENSIONS�������������������������������������������������39
10�0 WINTERISATION PROCEDURE���������������������40
10�1 START UP PROCEDURE AFTER
WINTERISATION ������������������������������������������������������40
11�0 WARRANTY CONDITIONS�����������������������������41
12�0 DECLARATION OF CONFORMITY����������������42
CONTENTS

41007332 ISSUE 5
OWNER/INSTALLATION MANUAL
Thank you for choosing is product, which is designed
for quiet and energy ecient operation. It is e ideal
way to heat your pool in an environmentally friendly
way.
This guide provides information needed to install and
operate e product effectively. Please ensure you
read is manual and use e correct installation and
operating procedures.
This manual is intended for installers and users�
Read e entire manual before using e heat
pump� Awareness of e correct operating
procedure for e machine and any safety devices
is important, to avoid damage or injury�
The appliance can be used by children aged from 8
years and above and persons wi reduced, physical,
sensory or mental capabilities or lack of experience
and knowledge if ey have been given supervision
or instruction concerning use of e appliance in a safe
way and understand e hazards involved. Children
shall not play wi e appliance. Cleaning and user
maintenance shall not be made by children wiout
supervision.
1�2 WARNINGS
Important safety information is contained in is manual
and marked on e heat pump.
Please read and follow all safety advice�
The refrigerant used in is heat pump is R32�
This refrigerant is environmentally friendly, but
safety instructions must be strictly adhered to�
The WARNING sign denotes a hazard� It calls
attention to a procedure or practice, which if not
adhered to could result in injury� Warning signs
and procedures must be complied wi�
If a refrigerant leak is suspected stop using e
heat pump and contact e service department�
info@danerm�com
Take e following precautions in order to avoid
any danger:
REFRIGERANT SAFETY:
This heat pump contains R32 refrigerant� Work
on e refrigeration system, repair and disposal
must be carried out by appropriately qualified and
registered engineers�
Repair, service and disposal must be carried out in e
EU by F-Gas registered engineers.
Completely de-gas e refrigerant before any brazing
is performed. Brazing can only be carried out by
technicians trained to EU 517/2014.
Risk assessments must be carried out before
maintenance or repairs are started.
Appropriate safety measures and risk assessments
must be taken before work commences.
Do not attempt to work on e equipment by
yourself�
Consult e qualified engineer undertaking e work to
establish all requirements before work commences.
1�1 FOREWORD
1�0 INTRODUCTION

5
1007332 ISSUE 5
ACTIONS TO AVOID (OPERATION AND
HANDLING):
Be especially careful when handling e heat pump,
not to cause any damage at may result in leakage of
e cooling circuit.
Do not use means to accelerate e defrosting process
or to clean, oer an ose recommended by e
manufacturer.
Do not pierce or burn.
IN CASE OF FIRE:
Toxic fumes may occur in e event of fire. You must
leave e room as quickly as possible in e event of
fire.
LOCATION REQUIREMENTS:
The heat pump contains R32 refrigerant so e
following location requirements must be fulfilled:
The heat pump must be kept away from sources of fire
or naked flames.
The heat pump must be installed, operated and
stored where the floor area is larger than the minimum
requirement., see section 3.2.
The heat pump shall be stored in a room wiout
continuously operating ignition sources (for example:
open flames, an operating gas appliance or an
operating electric heater).
Keep e ventilation openings clear of obstruction
during operation.
Do not use or store combustible gas or liquids near e
heat pump.
Check if ere are any local regulations, which
you must comply to, when installing or storing
e heat pump�
Be aware at refrigerants may not contain an
odour�

61007332 ISSUE 5
OWNER/INSTALLATION MANUAL
Installation must be carried out by competent people,
in accordance wi is manual.
INSTALLATION:
Read e instructions before installation, use and
maintenance.
If R32 gas leaks during e installation process, stop e
installation immediately and call e service centre.
If a repair is required, please contact e nearest aer-
sales service centre.
To avoid over heating or over cooling of pool water
check and set e temperature on e control panel.
The heating performance can be improved by
insulating e flow and return pipework.
It is recommended at a cover is used on e
swimming pool to reduce heat losses.
AIRFLOW:
The heat pump must have access to adequate airflow.
See section 3.1.
Do not place obstructions at will block air flow near
e inlet or outlet.
ELECTRICAL SAFETY:
Mains power isolator should be out of reach of children.
Aer a power cut, when e power supply is restored,
e heat pump may start up wiout warning.
Electric storms can damage electronic equipment.
Ideally e heat pump should be switched off at e
mains.
HEAT PUMP MALFUNCTION:
WARNING: Isolate heat pump electrically and wait
3 minutes before removing panels or entering heat
pump.
Refer to e user check list in section 5.2 and e error
codes listed in section 5.3 before initiating a service call.
Do not attempt to interfere wi any internal control
settings as ese have been factory calibrated and
sealed.
Any sign of abnormal operation such as water dripping
should be reported immediately to e installer. If
in doubt or if advice is required contact e Service
department.
MAINTENANCE:
Isolate e power supply of e heat pump and wait 3
minutes before cleaning examination or repair.
Please clean is machine wi household detergents
or clean water. NEVER use petroleum spirit, inners or
any similar fuel.
Check bolts, cables and connections regularly.
DISPOSAL:
Repair, service and disposal of redundant heat pumps
must be completed by auorised technicians. It is
illegal to allow refrigerant gases to escape to air.
Do not attempt to work on e equipment by yourself.
Improper operation may cause danger.

7
1007332 ISSUE 5
Do not use means to
accelerate e defrosting
process or to clean, oer an
ose recommended by e
manufacturer.
The appliance shall be stored
in a room wiout continuously
operating ignition sources
(for example: open flames, an
operating gas appliance or an
operating electric heater.
Do not piece or burn.
Be aware at refrigerants
may not contain an odour.
Appliance shall be installed,
operated and stored in a
room wi a floor area larger
an Xm2, where X is e
“minimum area” shown in
section 3.2 and section 8.0.
The heat pump must be kept
away from sources of fire or
naked flames.
The heat pump must be
installed in well ventilated
area. Closed areas are not
permitted.
Repair and disposal must
be carried out by F-Gas
registered engineers.
Completely de-gas e
refrigerant before any brazing
is performed. Brazing can only
be carried out by technicians
trained to EU 517/2014.

81007332 ISSUE 5
OWNER/INSTALLATION MANUAL
2�1 TRANSPORTATION
Always keep e heat pump upright.
Do not li e heat pump by e water inlet or
outlet connections.
(If is is done e titanium heat exchanger inside e
heat pump could be damaged).
2�2 ACCESSORIES
These accessories are provided wi e heat pump.
Water union connectors
2 x 1½,
2 x 50mm
Drainage kit
Rubber Feet
(kit of 4)
x
2�0 ABOUT YOUR HEAT PUMP

9
1007332 ISSUE 5
2�3 OPTIONAL ACCESSORIES
The following items are additional accessories available
for purchase.
Remote controller kit for indoor installation.
(10m extension cable).
Winter cover.

10 1007332 ISSUE 5
OWNER/INSTALLATION MANUAL
2�4 FEATURES
• Stepless DC inverter compressor
• EEV Technology (Electronic Equalisation Valve)
• Quick reverse cycle defrosting wi 4-way valve
• High-eciency twisted titanium heat exchanger
• High pressure and low pressure protection
• So start and wide voltage application
• Stable inverter control system
2�5 OPERATING CONDITIONS AND RANGE
Air temperature operating range:
HPP-i 8, 12, 16: -5-43°C
HPP-iw 12, 16, 22: -10-43°C
Water temperature setting range:
Heating: 18°C-40°C
Cooling: 12°C-30°C
2�6 OPERATING MODES
The heat pump has two modes: Boost mode and
Whisper mode.
Mode Modes Characteristics
Boost mode
Heating capacity: 20% to 100% capacity
Intelligent optimization
Fastest heating
Whisper mode
Heating capacity: 20% to 80% capacity
Sound level: 3dB(A) lower an Boost mode
Questo manuale è adatto per i seguenti modelli
8
Indice
Lingue:
Altri manuali Dantherm Pompa di calore
Manuali Pompa di calore popolari di altre marche

Mitsubishi Electric
Mitsubishi Electric PUZ-SWM60VAA Manuale utente

Dimplex
Dimplex LI 16I-TUR Guida utente

Carrier
Carrier WSHP Open v3 Guida rapida alla configurazione

TGM
TGM CTV14CN018A Manuale utente

Carrier
Carrier 38MGQ Series Manuale utente

Kokido
Kokido K2O K880BX/EU Guida alla risoluzione dei problemi