S62…M
Background suppression
INSTRUCTION MANUAL
CONTROLS
OUTPUT LED (yellow)
The yellow LED ON indicates that the N.O. output is closed and the N.C.
output is open.
STABILITY LED (green)
When permanently ON, the green LED indicates a normal operating condition
where the received signal has a safety margin superior to 30% respect to the
output switching value. The sensor is ready to function correctly (stability
condition).
DISTANCE ADJUSTMENT TRIMMER (ADJ.)
A 6-turn trimmer allows the background suppression distance adjustment
through a mechanical variation of the optic triangulation angle.
The operating distance increases, rotating the screws in a clockwise direction.
Please refer to the “SETTING” paragraph for acquisition or setup procedure
indications.
POSITION INDICATOR
This indicator presents a scale numbered from 1 to 6 that allows a precise
adjustment of the suppression distance in the entire operating range.
Please refer to the “SETTING” paragraph for use indications.
TIMER ADJUSTMENT TRIMMER (only. M05/M15/M25/M35 vers.)
This control allows to vary the output delay deactivation from 0 to 1 sec.
Please refer to “TIMER FUNCTIONS” paragraph for use indications.
INSTALLATION
The sensor can be positioned by means
of the three housing’s holes using two
screws (M4x25 or longer, 1.5Nm max.
tightening torque) with washers.
Various orientable fixing brackets to
ease the sensor positioning are
available (please refer to the general
catalogue).
The operating distance is measured
from the front surface of the sensor optics.
The M12 connector can be oriented at two different positions using the
specific fastening spring and rotating the block of 180°.
CONNECTIONS
M12 connector
TECHNICAL DATA
S62-M0… S62-M1… S62-M2… S62-M3…
Power supply: 10 … 30 VDC
Ripple: 2 Vpp max.
Consumption
(output current excluded): 40 mA max.
Outputs: PNP or NPN N.O./N.C.; 30 Vdc max. (short-circuit protection)
Output current: 100 mA (overload and overvoltage protection)
Output saturation voltage: ≤2 V
Response time: 500 µs 1 ms 1,5 ms
Switching frequency: 1 kHz 500 Hz 330 Hz
Emission type: RED (660 nm) INFRARED (880 nm)
Spot dimension: 6x6 mm (at 200 mm) 15x15 mm (at 400 mm) 200x200 mm (at 2000 mm)
Operating distance (typical values): 30…300 mm 60…600 mm 60…1200 mm 200…2000 mm
(recommended target 400x400mm)
Adjustment: Multiturn distance adjustment trimmer / Timer adjustment trimmer (only M05/M15/M25/M35 vers.)
Difference (90% white / 4% black): < 8 % < 12 % < 25 % < 30 %
Hysteresis (90% white): < 5 % < 20 %
Indicators: OUTPUT LED (YELLOW) / STABILITY LED (GREEN)
Operating temperature: -10 … 55 °C
Storage temperature: -20 … 70 °C
Insulating strength: 500 Vac 1 min., between electronics and housing
Insulating resistance: >20 MΩ500 Vdc, between electronics and housing
Ambient light rejection: According to EN 60947-5-2
Vibrations: 0.5 mm amplitude, 10 … 55 Hz frequency, for each axis (EN60068-2-6)
Shock resistance: 11 ms (30 G) 6 shock for each axis (EN60068-2-27)
Housing material: ABS
Lens material: PMMA window; PC lens
Mechanical protection: IP67
Connections: 2 m cable ∅4 mm / M12-4 pole connector
Weight: 90 g. max. cable vers. / 40 g. max. connector vers.
SETTING
Suppression distance setting
1.Object detection
Position object to detect in front of the sensor at the distance required.
Turn distance adjustment trimmer (ADJ) to minimum: yellow LED OFF and
green LED ON.
Rotate trimmer in a clockwise direction until the yellow LED and green LED
turn ON. Object detection condition (A status of position indicator)
A
2.Background suppression
Remove object and ensure that the background is in front of the sensor:
yellow LED OFF and green LED ON.
Rotate trimmer in a clockwise direction until the yellow LED and green LED
turn ON: background detection condition (B status of position indicator).
B
The trimmer reaches maximum level with yellow LED OFF if the background
is outside the operating range.
Rotate trimmer in an anticlockwise direction until yellow LED turns OFF
and green LED ON: condition where background is outside operating
range (C status of position indicator).
C
3.Setting and control
Rotate trimmer in an anticlockwise direction until the indicator reaches
an intermediate point between position A and C.
If position A and C are close to each other, leave trimmer on position C.
The sensor is now ready to function correctly and in stable conditions:
DIAGRAMMA DI RILEVAZIONE
DIMENSIONS
Ø4
18.4
1114
POSITION INDICATOR
DISTANCE ADJUSTMENT TRIMMER
OUTPUT LED
STABILITY LED
10.7
mm
42
50
6
11
6.18
TIMER ADJUSTMENT
TRIMMER (mod.M05/M15/M25/M35)
M12
Ø15
14
CABLE VERSION
18x45°
16
42
50
0.75
1.1
2
18
4.7
EMITTER
RECEIVER
18.215.5
TIMER FUNCTION (S62…M05/M15/M25)
The timer function allows to adjust the output deactivation delay when the
object is outside the detection area. The delay extends the output activation
allowing the slower interface systems to detect shorter pulses.
The delay adjustment is carried-out manually using the Timer adjustment
trimmer. Clockwise rotation increase the delay from 0 to a max. 1 sec. value.
EX-II-3-D T6
Temperature class:
T6 (<85°C)
Max. Power consumption: 1260 mW at 30 Vdc
Max. Internal capacitance: 130 nF
Internal inductance: negligible
DECLARATION OF CONFORMITY
We DATASENSOR S.p.A. declare under our sole responsibility that these products are conform to the
2004/108/CE, 2006/95/CE Directives and successive amendments.
WARRANTY
DATASENSOR S.p.A. warrants its products to be free from defects.
DATASENSOR S.p.A. will repair or replace, free of charge, any product found to be defective during the
warranty period of 36 months from the manufacturing date.
This warranty does not cover damage or liability deriving from the improper application of
DATASENSOR products.
DATASENSOR S.p.A. Via Lavino 265
40050 Monte S. Pietro - Bologna - Italy
Tel: +39 051 6765611 Fax: +39 051 6759324
http://www.datasensor.com e-mail: info@datasensor.com
DATASENSOR S.p.A. cares for the environment: 100% recycled paper.
DATASENSOR S.p.A. reserves the right to make modifications and improvements without
prior notification.
826002872 Rev.C