DAUDIN iO-GRID m Manuale utente

iO-GRID M
Counter Module
User Manual
2301TW
V2.0.0

2
Table of Contents
1. Counter Module List........................................................................................................3
Product Description.........................................................................................................3
2. Counter Module Specification ..........................................................................................5
2.1 GFDI-RM02N......................................................................................................5
3. Counter Module Information ............................................................................................6
3.1 Counter Module Dimensions .................................................................................6
3.2 Counter Module Panel Information.........................................................................7
3.3 Counter Module Connections.................................................................................8
3.4 Counter Module Modes.........................................................................................9
4. Module Installation/Disassembly ....................................................................................10
4.1 Installation.........................................................................................................10
4.2 Removal............................................................................................................11
5. iO-GRID M Series Introduction......................................................................................12
5.1 iO-GRID M Components ....................................................................................12
6. I/O Module Parameter Settings and Introduction ..............................................................15
6.1 I/O Module Settings and Connections...................................................................15
6.2 i-Designer Program Tutorial ................................................................................17
7. Counter Module Control Register Description..................................................................21
7.1 Counter Module Register Communication Method.................................................21
7.2 Modbus function code 0x03 Demonstration...........................................................23
7.3 Supports Modbus Function Code .........................................................................24

3
1. Counter Module List
Product No. Description Remarks
GFDI-RM02N 4-channel counter module (24VDC, 0138 terminal block)
Product Description
GFDI, digital input module series is specially designed for industrial applications. Its the open-type
industrial equipment which is intended for installation within enclosures supplied in the field. A digital
input detects if a voltage is above/below a specific threshold. If the voltage is higher than the value, the
controller will detect the digital input as high/1. Or if lower than the value, the controller will detect the
digital input as low/0. And its circuit design & all the components of GFDI series are compliant with the
latest requirements and standards of UL, CE & RoHS. It has a complete circuit protection design to resist
overload, overvoltage and short circuit etc. It is avoided to damage & failure caused from improper
operations.

4
Caution (ATTENTION):
1. THIS DEVICE IS FOR INDOOR USE ONLY, DON’T PUT OR USE IT IN HIGH TEMPERATURE AND HIGH
MOISTURE ENVIRONMENT.
CET EQUIPEMENT EST DESTINE A UN USAGE INTERIEUR UNIQUEMENT NE PAS STOCKER OU
UTILISER DANS UN ENVIRONNEMENT A HAUTE TEMPERATURE ET HAUTE HUMIDITE.
2. AVOID FALLING AND BUMPING OTHERWISE THE ELECTRICAL COMPONENTS WILL BE DAMAGED.
ÉVITEZ DE TOMBER ET DE VOUS ÉCRASER, SINON LES COMPOSANTS ÉLECTRIQUES SERONT
ENDOMMAGÉS
3. DON’T TRY TO DISASSEMBLE OR OPEN THE COVER UNDER ANY CIRCUMSTANCE IN ORDER TO
AVOID DANGER.
NE TENTEZ JAMAIS DE DEBALLER OU D'OUVRIR LE COUVERCLE POUR EVITER TOUT DANGER.
4. IF THE EQUIPMENT IS USED IN A MANNER NOT SPECIFIED BY THE MANUFACTURER, THE
PROTECTION PROVIDED BY THE EQUIPMENT MAY BE IMPAIRED.
SI L'APPAREIL N'EST PAS UTILISE DE LA MANIERE INDIQUEE PAR LE FABRICANT, LA PROTECTION
FOURNIE PAR L'APPAREIL PEUT ETRE ALTEREE.
5. THE INSTALLATION THAT THE SAFETY OF ANY SYSTEM INCORPORATING THE EQUIPMENT IS THE
RESPONSIBILITY OF THE ASSEMBLER OF THE SYSTEM.
L'INSTALLATION DE TOUT SYSTÈME INTÉGRANT CET ÉQUIPEMENT EST LA RESPONSABILITÉ DU
CONSTRUCTEUR DU SYSTÈME.
6. USE WITH COPPER CONDUCTORS ONLY. INPUT WIRING: MINIMUM 28 AWG, 85°C, OUTPUT WIRING:
MINIMUM 28 AWG, 85°C
DESTINÉ À ÊTRE UTILISÉ AVEC DES CONDUCTEURS EN CUIVRE SEULEMENT. CABLAGE D'ENTREE:
MINIMUM 24 AWG, 85 ° C. CABLAGE DE SORTIE: MINIMUM 28 AWG, 85 ° C.
7. FOR USE IN A CONTROLLED ENVIRONMENT. REFER TO MANUAL FOR ENVIRONMENTAL
CONDITIONS.
POUR UN ENVIRONNEMENT CONTROLE. REPORTEZ-VOUS AU MANUEL DES CONDITIONS
ENVIRONNEMENTALES.
8. DISCONNECT ALL SOURCES OF SUPPLY BEFORE SERVICING.
COUPER TOUTES LES SOURCES D’ALIMENTATION AVANT DE FAIRE L’ENTRETIEN ET LES
RÉPARATIONS.
9. PROPER VENTILATION IS REQUIRED TO REDUCE THE RISK OF HAZARDOUS OR EXPLOSIVE GAS
BUILDUP DURING INDOOR CHARGING. SEE OWNERS MANUAL.
UNE VENTILATION ADÉQUATE EST NÉCESSAIRE AFIN DE RÉDUIRE LES RISQUES
D’ACCUMULATION DE GAZ DANGEREUX OU EXPLOSIFS DURANT LA RECHARGE À L’INTÉRIEUR.
VOIR LE MANUEL D’ENTRETIEN.

5
2. Counter Module Specification
2.1 GFDI-RM02N
Technical Specification
Number of Inputs 4
Voltage Supply 5 VDC via Dinkle Bus
Current Consumption 37 mA @ 5 VDC
Connection Type Max. 100Hz
Breakover Voltage 15…30 VDC
Cut-off Voltage 0…10 VDC
Communication Interface RS485 via Dinkle Bus
Communication Specification
Communication Protocol Modbus RTU
Format N, 8, 1
Baud rate range 1200-1.5 Mbps
General Specification
Dimension (W*D*H) 12 x 100 x 97mm
Weight 60 g
Ambient Temperature (operation) -10…+60˚C
Storage Temperature -25˚C…+85˚C
Permissible Humidity(non-condensing) RH 95%
Altitude Limit < 2000 m
Ingress Protection (IP) IP 20
Pollution Severity II
Safety Approval CE
Produce Certification UL / CSA / IEC 61010-2-201&-1
Wiring Range (IEC / UL) 0.2 mm2 ~ 1.5 mm2 / AWG 28~16
Wiring Ferrules DN00510D、DN00710D

6
3. Counter Module Information
3.1 Counter Module Dimensions
Unit: mm

7
3.2 Counter Module Panel Information
Terminal block connector definitions
Terminal block
labeling
Connector
definitions
Terminal block
labeling
Connector
definitions
+11 Channel 0 +31 RST 0
-12
Channel 0
-32
RST 0
+13 Channel 1 +33
RST 1
-14
Channel 1
-34
RST 1
+21 Channel 2 +41
RST 2
-22
Channel 2
-42
RST 2
+23 Channel 3 +43
RST 3
-24
Channel 3
-44
RST 3
←Module label
←CH0
←CH1
←CH2
←CH3
←RST0
←RST1
←RST2
←RST3

8
3.3 Counter Module Connections
CH0+
CH0-
CH1+
CH1-
CH2+
CH2-
CH3-
CH3+
RST3+
RST3-
RST0+
RST0-
RST1+
RST1-
RST2+
RST2-

9
3.4 Counter Module Modes
UP (incremental) mode
Displayed
value
Count input; CH1 -: Prohibits (gateway) input
must be higher than the minimum signal width value
Displayed
value
must be higher than the minimum signal width value
: Prohibits (gateway) input; CH1 -: Count input

10
4. Module Installation/Disassembly
4.1 Installation
I. Align the red arrow on the side of the module to the arrow on the DIN rail.
II. Press the module down and the metal clamp will slide (thanks to its spring
mechanism)
and grab on the other side of the DIN rail. Continue to push down until the metal
clamp “clicks”.
*Note: Make sure the red arrows on the module and the rail are pointing the same direction.
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali DAUDIN Portale
Manuali Portale popolari di altre marche

LST
LST M500RFE-AS Manuale utente

Kinnex
Kinnex Media Gateway Manuale utente

2N Telekomunikace
2N Telekomunikace 2N StarGate Manuale utente

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Manuale utente

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE Manuale utente

Telsey
Telsey CPVA 500 - SIP Manuale utente