DCI C1103 Manuale utente

• C1103
• C1203
• C2106
• C2206
• C3210
Copyright © 2006 DCI. All Rights Reserved.
Compressor Installation Guide
C Series
COMPRESSOR
92094, Rev. D, 08/13

1 www.dcionline.com www.dcionline.com

Oil-Less
C Series Installation Guide
Compressor Model Specification
C - Series
Compressor
# Heads Tank Power
Model # # of Heads Tank Size Voltage Breaker Size Amps
C1103 1 Horizontal 20 gal. 115 20 Amps 13.4
C1203 1 Horizontal 20 gal. 230V 20 Amps 6.7
C2106 2 Horizontal 20 gal. 115V 30 Amps 26.8
C2206 2 Horizontal 20 gal. 230V 20 Amps 13.4
C3210 3 Horizontal 30 gal. 230V 30 Amps 20.1
NOTE: Installation of this product should be undertaken only
by qualified service technicians.
This product has been factory-tested prior to shipment.
If the product does not function as described in the start-up and
test procedures in this manual, call the number below for assistance.
Technical Support: 1-800-624-2793
NOTE: Air flow rates in excess of compressor ratings will result
in reduced performance and possible overheating.
All Voltage Ratings ± 5%.
Space Requirements
Power
NOTE: 1) All machines are of the 3 wire grounded system type.
2) Minimum Breaker size 30 amp & larger wire size #10 supply connection.
29.50"
23"
11.69"
16"
39"
33"
46" 26"
1.800.624.2793 1

Installation Kit
The C - Series is shipped with the following:
C Series Installation Guide
Compressor Installation Kit
•
•
Installation Kit
You must provide:
Fittings and bushings as required to connect the
flexible hose to the on-site piping (the hose-end
is 3/8 in. NPT “male”).
Earthquake restraints for securing the equipment
if required by local codes.
Antivibration Foot
Nut
Lock Washer
Flat Washer
Wire Nuts
Split Bushing
Conduit Connector 6 ft. Hose
www.dcionline.com
2

Site Requirements
Clearance Site Requirements
Adequate clearance as shown below for servicing and air circulation — room
temperature should be maintained between 40°F and 100°F when the motors
are running.
A flat, level floor that provides stable support.
Protection from the weather and direct sunlight.
A power source within 3 ft. of back-center that provides a dedicated,
breaker-protected circuit.
•
•
•
•
C Series Installation Guide
Compressor Site Requirements
WARNING! Fire Hazard! Running motors generate heat. Do not store flammable
liquids or objects such as clothing, mops, or brooms near or above the unit.
ELECTRICAL REQUIREMENTS
PLUMBING REQUIREMENTS
1. 1/2 in I.D. minimum pipe size.
2. Pipe connection is to be located within 3 ft of
center back of compressor.
3. Install per all Local and State plumbing codes.
1. 3 wire single phase 115 vac or 230 vac. All
voltage ratings ± 5%.
2. Green Wire is to be grounded to a suitable
system ground.
3. Power supply must be on a dedicated circuit.
4. See data tag for appropriate breaker size.
5. Power supply connection is to be located
within 3 ft of center back of compressor.
6. Install per all local and State electrical codes.
1.800.624.2793 3

U
n-
packing
1 www.dcionline.com
C Series Installation Guide
Unpacking
Unpacking
NOTE: Returns must be in the original packaging. Retain the packaging until
installation and test are complete.
Step One:
Unbolt the crate from the pallet
and remove crate intact.
Step Two:
Remove the four bolts that
secure the C - Series to the
pallet and put them with the
other packaging.
Step Three:
Mount the four rubber feet.
www.dcionline.com
4

C Series Installation Guide
Unpacking
Unpacking
Step Four:
Grasp the C - Series by the tank and
move it into position.
NOTE: Returns must be in the original packaging. Retain the packaging until
installation and test are complete.
1.800.624.2793 5

U
n-
packing
1 www.dcionline.com
C Series Installation Guide
Installation
Installation
WARNING! Do not connect rigid pipe directly to the compressor. Motor vibration
loosens fittings, causing leaks. Use the flexible pipe provided or a similar substitute.
Step One:
Make sure the power supply is turned off and matches the voltage rating of the motors.
Note: Appropriate Breaker size is listed on the machine data tag.
Step Two:
Connect the power, making sure to adhere to all local and state codes.
Connect the “Green” Ground wire to an earth ground.
Note: 3 wire system.
Step Three:
Attach the flexible piping and connect to on-site piping.
Note:
Install appropriate over current protection; i.e., circuit breaker.
Model # Breaker Size
C 1103 20 Amps
C 1203 20 Amps
C 2106 30 Amps
C 2206 20 Amps
C 3210 30 Amps
Electrical
www.dcionline.com
6

C Series Installation Guide
Start-Up & Test
Un
p
ackin
g
Start-Up & Test
Step One:
Turn off the switches on the front of the compressor.
Step Two:
Ensure that the dryer by-pass shut-off valve is open.
Step Three:
Ensure that strainer shut-off valve is open.
Step Four:
Close outlet valve on the compressor tank.
Step Five:
Apply power to system — the purge valve my emit a hissing sound as the purge timer resets.
Step Six:
Switch on the motors. If you hear the popping sound of air escaping the relief valve, the dryer by-pass valve is closed.
1.800.624.2793 7

Un
p
ackin
g
1 www.dcionline.com
C Series Installation Guide
Start-Up & Test
Start-Up & Test
Step Seven:
As the tank pressurizes, watch the
pressure gauge. If the pressure switch
is functioning normally, the motors will
shut off at approximately 100 PSI.
Wait five minutes and watch the gauge
to ensure there are no leaks in the
C Series. The system should lose
no more than one PSI per minute.
Step Eight:
Test the purge valve by pressing the
TEST button. If the valve is functioning
normally, you will hear the hiss of air
escaping for approximately ten seconds.
NOTE! Do not adjust the timer dials on the purge valve.
If the purge timing needs adjustment, call technical support.
3
0
27
0
9
0
6
0
21
12
9
6
3
0
BAR
100xkPa
psi
2
4
0
18
1
2
0
180
210
150
3
00
0
15
www.dcionline.com
8
Altri manuali per C1103
1
Questo manuale è adatto per i seguenti modelli
4
Indice
Altri manuali DCI compressore d'aria