DEKKER Vacuum Technologies, Inc. Part No. 9983-0000-E02 September 2019
ON LED is used to display if the system is running or in standby mode. Green =
System is either running or in Standby mode.
ON button is used to start the system.
OFF button is used to stop the system.
OFF LED is used to display if the system is stopped. Red = System is stopped.
RUN STATUS LED is used to display the current run status. Green = System is
running. Orange = System is in Standby or Auto mode. Red = System is stopped.
RESET button is used to reset faults. Note: Fault condition must be cleared before the Reset
button will reset the fault.
LO button is used to access the Fault History Log menu.
MAINTENANCE button (MAIN) is used to access menu for the Spare Parts List, Maintenance
Schedule and Service History.
PRO RAM button (PROG) is used to access the Programming menu for Setpoints,
Clock, Vacuum Units, Temperature Units and other keycode options that are
purchased after the original sale (such as hi or low-level switches, backpressure, etc).
ESCAPE button (ESC) is used to return to the Run Standby Stopped screen.
BATTERY
The Dekker Controller may be shipped with a battery protector placed between the battery clip and the
surface of the battery, it may be a rubber sleeve around the clip or a small plastic insulator between the
clip and battery. This must be removed before applying power to the controller. If not removed the
controller will not retain Date, Time and other values that are written to the controller for setup. The
controller cannot be flashed with new firmware until this is removed. To remove, use a pair of needle
nose pliers and pull from clip.