Delta Membranes AlertMaxx2 Istruzioni per l'installazione

Installation & Operating Manual
Pump Station High Level Alarm
AlertMaxx2
Foul Water (DMS-299)

AlertMaxx2
AM2F-M-V3-10.17
Legal information/Copyright
All rights reserved. Contents provided herein must neither be distributed, copied, reproduced, edited or
processed for any other purpose, nor otherwise transmitted, published or made available to a third party without
express written consent from Delta Membranes.
Subject to technical modication without prior notice.
© Delta Membranes 2017
Delta House, Merlin Way, North Weald, Epping, Essex. CM16 6HR
01992 523 523
www.deltamembranes.com
T.
E.
W.

AlertMaxx2
3
Contents
1.0 AlertMaxx2 overview 4
2.0 Box contents 4
2.1 Cardboard box contents 4
2.2 AlertMaxx2 unit contents 4
3.0 Technical information 5
4.0 Health & Safety 5
5.0 Guarantee 5
6.0 Unit location 5
7.0 Mounting the AlertMaxx2 unit 5
8.0 Wiring schematic 6
9.0 Connecting mains power to the AlertMaxx2 7
10.0 Connecting a pump to the AlertMaxx2 8
11.0 Installing a pendant oat into a foul water chamber 9
12.0 Connecting a pendant oat to the AlertMaxx2 unit 10
13.0 Activating & testing the AlertMaxx2 unit 11
13.1 Connecting the ribbon cable 11
13.2 Turning on the AlertMaxx2 unit for the rst time 11
13.3 Testing the AlertMaxx2 unit 11
14.0 Connecting external devices 12
15.0 Energy monitoring 12
16.0 Servicing 12
17.0 Spares 12
18.0 Error codes 13
19.0 Troubleshooting 14
20.0 PPS Technical Department 14
21.0 Hi-PowerMaxx Connection 15

1.0 AlertMaxx2 overview
2.0 Box contents
4
AlertMaxx2
3.0 Technical information
AlertMaxx2 Specication
Size (without cable glands) W: 310mm x D: 170mm x H: 78mm
Weight (AlertMaxx2 unit) 1kg
Mains Supply 200-250V AC (50Hz)
Internal Battery Pb 6V - 1.2Ah
Alarm Sound Level 100db @ 30cm
Visual Display 2 x 7 Segment
Operating Temperature 5-40°C
Approximate Installation Time 30 minutes
IP Rating IP2X
2.1 Cardboard box contents
• 3 x Large Cable Glands & Nuts
• 5 x Large Blanking Plugs & Nuts
• 1 x Small Cable Gland & Nut
• 2 x Small Blanking Plugs & Nuts
• 1 x 6V Battery
2.2 AlertMaxx2 unit contents
• 1 x AlertMaxx2 Unit
• 1 x Chamber Location Sticker Sheet (For AlertMaxx2)
• 1 x Chamber Location Sticker Sheet (For Spurs)
• 1 x Installation & Operating Manual (this document)
• 1 x Homeowner Pack
• 1 x Pendant Float Switch
• 2 x Cable Ties
The AlertMaxx2 is an intelligent high level alarm, designed to alert home owners when the water level in their
pump chamber becomes too high. The unit will also inform home owners when a service is due on their pump
station.
CAUTION!
The AlertMaxx2 should only be installed by qualied personnel in accordance with the latest regulations.

AlertMaxx2
5
6.0 Unit location
The AlertMaxx2 must be positioned in an area where the alarm can be clearly heard and is permanently
accessible for servicing. The unit must be positioned where there is sucient air circulation to the front and base
vents. The AlertMaxx2 must not be located further than 10m from the pump/s it is being used in conjunction
with. If cable extensions are required, these must be selected in accordance with BS 7671:2008 ‘Requirements
for Electrical Installations’. If using in conjunction with a PowerMaxx battery backup, please ensure the units are
no further than a 20m cable length from each other. The AlertMaxx2 should be positioned in an area where
there is a good Wi-Fi signal strength.
7.0 Mounting the AlertMaxx2 unit
CAUTION!
The AlertMaxx2 unit is not waterproof and must be installed indoors or inside a kiosk.
1. Remove the screws from the front of the unit that secure the front fascia (the internal ribbon cable will be
disconnected on supply).
2. Using the 4 mounting holes provided, mark, drill and t suitable wall plugs in to the chosen wall for
installation (ensure correct wall plugs are used for the wall type).
3. Secure the AlertMaxx2 unit to the wall using appropriate screws for the wall plugs used.
PLEASE NOTE
When securing the unit to the wall, avoid overtightening the screws as this may cause the box to crack.
4.0 Health & Safety
In order to minimise the risk of ill health or accidents when installing and/or servicing pump chambers and
associated accessories, workers must be fully trained and competent. The following guidelines will help
safeguard matters:
• Assessing the risk and working in accordance with the control measures identied.
• Ensure electrical power to the equipment is isolated before carrying out installation or maintenance.
• A suitable rst aid kit must be close to hand.
• The electrical installation must comply with the requirements of BS 7671:2008 ‘Requirements for Electrical
Installations’ incorporating amendment 3:2015.
5.0 Guarantee
AlertMaxx2 is oered with a 24 month component guarantee. This guarantee only covers any defects in
workmanship, construction or material. This guarantee does not cover, defects caused by incorrect installation,
installer error, abnormal working conditions, misuse or neglect.

8.0 Wiring schematic
6
AlertMaxx2
The AlertMaxx2 is dierent from a standard high level alarm as the pump/s require to be fed through the unit.
This way of connectivity allows the AlertMaxx2 to collect various dierent parameters directly from the pumps
and when connected via Wi-Fi, this data can be used to intelligently plan maintenance and service schedules to
the specic pump station it is connected to (see page 15).
Figure 1. AlertMaxx2 wiring schematic
AlertMaxx2 High Level Alarm
(DMS-269-2)
For internal wiring of the high
level alarm, please refer to the
AlertMaxx2 instruction manual.
- The pump is supplied with a 10m cable.
- When only using the standard 10m
cable attached to the pump, the cable
duct should be no longer than 6m.
- If the cable duct requires to be longer
than 6m, please follow the cable
extension guide to select an appropriate
cable core diameter.
Finger Float Switch
Supplied with a 10m cable
The electrical installation must comply with the requirements of
BS 7671:2008 ‘Requirements for
Electrical Installations’ incorporating amendment 3:2015
Separate 16 Amp RCBO’s
13 Amp Non-switched
fused spur

AlertMaxx2
7
1. Insert 2 large cable glands into the far right hand side of the AlertMaxx2 unit.
2. Using the wiring schematic (gure 1), feed the mains power cable through the relevant cable gland
and connect the power cable to the corresponding terminal block on the main PCB (gure 2).
WARNING!
Ensure mains power is isolated before connecting and wiring to the AlertMaxx2 unit.
Figure 2. Connecting mains power
9.0 Connecting mains power to the AlertMaxx2
PLEASE NOTE
For ease of installation, each gland is located directly opposite its relevant terminal block.
Follow the internal sticker for wiring guidance.

10.0 Connecting a pump to the AlertMaxx2
8
AlertMaxx2
1. Using the remaining cable gland previously installed in section 9.0, feed the pump cable through the
gland and connect to the corresponding terminal block on the main PCB (gure 3).
Figure 3. Connecting pump

AlertMaxx2
9
11.0 Installing a pendant oat into a foul water chamber
Figure 5. Foul Water Sump (DMS-165-1)Figure 4. Foul Water Float Switch
Option 1 - Free standing foul pump
1. Using the cable tie provided, attach the oat cable to the discharge arm allowing the bottom of the oat
switch to hang approximately 200mm above the base of the chamber (gure 5).
Option 2 - Guide rail mounted foul pump
1. Pull the oat cable through the oat weight.
2. Using a cable tie, secure the oat weight to the oat cable so there is 80mm of oat cable between the
top of the oat switch and the bottom of the oat weight.
3. Drill a hole through the oat bracket. Hang the pendant oat from the oat bracket so the bottom of the
oat switch hangs approximately 200mm from the base of the chamber. Once the pendant oat is at the
correct height, secure the oat cable to the oat bracket using a cable tie.
BROWN
BLACK
ENL
40
120
20
70
50
80
PLEASE NOTE
The pendant oat switch should be located in a position where the oat can pivot with rising water levels and
not become obstructed (gure 5).
200mm

12.0 Connecting a pendant oat to the AlertMaxx2 unit
10
AlertMaxx2
1. Using a draw cord, pull the oat cable through the cable duct on the chamber.
2. Insert a large cable gland into the far left hole of the AlertMaxx2 unit.
3. Pull the oat cable through the large cable gland on the AlertMaxx2 unit.
4. Connect the black and blue cables from the oat switch cable to the terminal strip (gure 6).
The brown cable should be disregarded and isolated to avoid possible shorting.
PLEASE NOTE
If the cable supplied with the oat switch is too short, the cable can be extended using a cable with a
minimum core cross sectional area of 1mm².
Figure 6. Wiring a pendant oat switch
PLEASE NOTE
Only the rst two (far left) inputs on the oat terminal block are used - Blue & Black
Questo manuale è adatto per i seguenti modelli
1
Indice
Manuali Sistema di sicurezza popolari di altre marche

EDM
EDM Solution 6+6 Wireless-AE Manuale utente

Highway Safety Group
Highway Safety Group EA401 Manuale utente

Siren
Siren LED GSM Manuale utente

Detection Systems
Detection Systems 7090i Istruzioni per il montaggio

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Manuale utente

Siemens
Siemens FDM273 Manuale utente