DENTIS SQUVA Manuale utente

Global TOP 10 in Healthcare
SQUVA USER’S MANUAL
SQ UV ACTIVATOR
DENTIS CO., LTD.
99, Seongseoseo-ro, Dalseo-gu, Daegu, Korea
Tel. +82-53-583-2804, FAX. +82-53-583-2806 www.dentis.co.kr / www.dentisimplant.co.kr

Be sure to read the manual before using this product.
2
CONTENTS
1. Purpose of Use & Conditions for Use ......................................................................................................................... 3
1.1 Purpose of Use ................................................................................................................................................................... 3
1.2 Conditions for Use ............................................................................................................................................................. 3
2. CE & FCC.................................................................................................................................................................................... 3
2.1 FCC warning statement .................................................................................................................................................... 3
2.2 CE statement ....................................................................................................................................................................... 4
3. Warnings .................................................................................................................................................................................... 5
4. Warranty ..................................................................................................................................................................................... 6
5. Components and Specifications ...................................................................................................................................... 7
5.1 Components ........................................................................................................................................................................ 7
5.2 Specifications ...................................................................................................................................................................... 7
6. Use ................................................................................................................................................................................................ 8
6.1 Components ........................................................................................................................................................................ 8
6.2 How to use........................................................................................................................................................................... 9
6.3 Control part ...................................................................................................................................................................... 12
6.4 Sensor Explanation ......................................................................................................................................................... 13
7. Storage Method ................................................................................................................................................................... 13
8. Cleaning and Sterilization ............................................................................................................................................... 14
8.1 Cleaning and Sterilizing Fixture Driver ............................................................................................................. 14
8.2 Cleaning and Disinfection the Main Body ..................................................................................................... 14
8.3 Sterilization....................................................................................................................................................................... 14
9. Troubleshooting ................................................................................................................................................................... 14
“WARNING: Modification of this equipment is not allowed”

Be sure to read the manual before using this product.
3
1. Purpose of Use & Conditions for Use
1.1 Purpose of Use
The SQ UV ACTIVATOR is a product designed to increase hydrophicility on implant surface.
1.2 Conditions for Use
Ÿ Condition of Use
ž Temperature : 0 - 40 ℃
ž Relative humidity : 30 - 90 %RH
ž Atmospheric pressure : 0 - 2,000 m (106 - 80 Kpa)
Ÿ Transport environment
ž Temperature : 0 - 40 ℃
ž Relative humidity : 0 - 80 %RH
2. CE & FCC
2.1 FCC warning statement
Ÿ FCC Part 15.19(a)
This device complies with part15 of FCC rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation.
Ÿ FCC Part 15.105
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful Interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.

Be sure to read the manual before using this product.
4
- Consult the dealer or an experienced radio/TV technician for help
Ÿ FCC Part 15.21
Changes or modifications not expressly approved by the manufacturer (or party responsible)
for compliance could void the user’s authority to operate the equipment
Ÿ RF Exposure
This equipment should be installed and operated with minimum 20 cm between the radiator
and your body.
2.2 CE statement
Ÿ RED Article 10.2
This device can be operated in at least one MemberState without infringing applicable
requirements on the use of radio spectrum.
ž RF Range: 13,535 kHz ~13,587 kHz
ž Max Output Power(E.I.R.P.): -27.46 dBm

Be sure to read the manual before using this product.
5
3. Warnings
Warnings
Ÿ Please read the USER manual before using the product.
Ÿ Check all components after opening this product.
Ÿ Please install this product in a well ventilated place.
Ÿ Do not use it in uneven, sloping, or vibrating area.
Ÿ Do not use in water or wet areas.
Ÿ Do not touch the body and power plugs with wet hands.
Ÿ Do not pull the power cable when disconnecting the power plug, but hold the power
plug and disconnect.
Ÿ Please connect a grounded wall outlet.
Ÿ Use input power in the range of AC 100 – 240 V, 50/60 Hz.
Ÿ Do not use adapters other than those provided.
Ÿ This product has been certified by the Electromagnetic Compatibility KC, CE and FCC
Ÿ This product complies with EM standards. However, electromagnetic interference may
cause performance degradation when used improperly.
Ÿ Do not disassemble or separate except for experts designated by supplier.
(No warranty can be obtained if arbitrarily disassembled or separated)
Ÿ If the product displays an ozone warning on the LCD or smells strange (ozone smell),
ventilate it immediately, remove the power plug, and contact your supplier.
Ÿ Do not put any substances other than FIXTURE in the lifting section.
(Risk of failure or electric shock)
Ÿ After reforming the FIXTURE, after the pump stops (approximately 30 seconds), change
the other FIXTURE.
Ÿ Do not insert FIXTURE driver during product operation.
Ÿ Make sure to use products within 8mm diameter of FIXTURE.
Ÿ Use FIXTURE in combination with the FXIUTRE support.

Be sure to read the manual before using this product.
6
Ÿ Use the FIXTURE support in the correct position on the TRAY.
Ÿ Do not place objects on the TRAY.
Ÿ Do not place items on top of the product
Ÿ When operating the instrument, be careful not to cause external shock
Ÿ If the wire is damaged, stop using it and contact your supplier to replace it
Ÿ If your product smells of smoke or burning, please remove the power plug and contact
your supplier.
Ÿ Be careful when installing the product
Ÿ Contact your supplier if there is a fault or damage
Ÿ If it is not used for a long time, remove it from the outlet and store it
Ÿ In case of failure, do not forcibly separate the closed lifting part and contact the place
of purchase
Ÿ Do not remove the RFID CARD during use
Ÿ Please contact the supplier when the RFID CARD exceeds the limit.
Ÿ Dispose of the product in accordance with the laws of the country concerned
Ÿ Never use this product for any purpose other than its intended use
Ÿ The temperature of the FIXTURE driver is high after reforming, so be sure to wear latex
gloves
4. Warranty
Ÿ UV LAMP : 700 hrs
Ÿ O3 FILTER : 1 years
Ÿ Product : 1 years

Be sure to read the manual before using this product.
7
5. Components and Specifications
5.1 Components
No.
Description
①
SQ UV Activator
②
Adapter & Power Plug
③
FIXTURE Driver KIT
④
RFID CARD
5.2 Specifications
Category
Unit
Specification
Remark
Rated power input
-
AC 100 – 240 V , 50/60 Hz
Power consumption
W
137
Adapter Output
V
DC 24
W
250
Product size
mm
W336 x L185 x H330
Product weight
kg
6
Ozone accrual volume
ppm
Less than 0.05
Reforming time
s
10
Wavelength
nm
172
RF Range
kHz
13535 ~ 13587
RF Max Output Power(E.I.R.P.)
dBm
- 27.46
※ Values are measured with a tolerance of 10%
②
③
④
①

Be sure to read the manual before using this product.
8
6. Use
6.1 Components
MOTION SENSOR
SPEAKER
5” TOUCH LCD PANNEL
RFID CARD SLOT
TRAY
(FIXTURE INSERTION)
DC POWER
INPUT SOCKET
ON/OFF SWITCH
HANDLE
Product LABEL

Be sure to read the manual before using this product.
9
6.2 How to use
Step
Image
Description
1
Check the SQUVA components
- SQUVA
- Adapter
- RFID CARD
- Power Cord
- FIXTURE Driver KIT
- USER’S MANUAL
2
Connect the adapter and power cord.
Adapter outpt “4Pin Jack” at the back of
the body. (Pay attention to direction).
3
Plug the power cord into an outlet.
4
Turn on the power button at the back of
the main body.
5
Insert the RFID CARD into the designated
slot.

Be sure to read the manual before using this product.
10
6
Press the “OPEN” button on the LCD.
(Make sure the TRAY is downward.)
7
Prepare a FIXTURE to be reformed.
Close the sterilized FIXTURE support by
rotating it clockwise two to three times.
( The FIXTURE support must be
sterilized before use)
( Do not allow FIXTURE to touch hands
or other parts)
( Handle the ampoule to prevent
contamination)
( Check that the FIXTURE is fully
engaged in the FIXTURE driver. Incomplete
tightening may cause FIXTURE to fall
during process)
8
Place the FIXTURE support in the center
groove of the TRAY.
( Ensure that it is correctly seated in
the middle circle)
(
out of circle
)
(
lean
)
CORRECT
INCORRECT
Indice