DEVA DB9000-TX Manuale di istruzioni

Publish Date: 24-Feb-2017
How can the DB9000-TX be set
to act as a Streaming Audio Server,
sending audio to DB9000-RX decoder/s
used as an IP Audio Client
SET-UP INSTRUCTIONS

Contents
General information ......................................................................................................................... 4
Point-to-point audio transmission .................................................................................................. 4
Point to multi-point audio transmission ......................................................................................... 5
DB9000-TX and DB9000-RX Set-up .............................................................................................. 5
DB9000-TX Streaming Audio Server Set-up................................................................................... 6
DB9000-RX IP Audio client Set-up................................................................................................. 7
Appendix A ......................................................................................................................................... 8
Appendix B ....................................................................................................................................... 12

THIS PAGE
IS INTENTIONALLY
LEFT BLANK

65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: of[email protected] ,Web: www.devabroadcast.com
- 4 -
General information
The IP Audio encoder and decoder are controlled trough a build in WEB Server and a standard
web browser is used to monitor their status or to make some adjustments. To operate the devices
you need to know their IP Address. In case you are not aware of the IP Addresses and how to open
the WEB interface, please refer to “Appendix A - DB9000-TX Quick User Guide” on page 7 and
“Appendix B - DB9000-RX Quick User Guide” on page 11.
This conguration allows two types of applications:
POINT-TO-POINT AUDIO TRANSMISSION

65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: of[email protected] ,Web: www.devabroadcast.com
- 5 -
POINT TO MULTI-POINT AUDIO TRANSMISSION
IMPORTANT NOTE: One DB9000-TX can send audio to maximum ten DB9000-RXs.
However, in order for stable connectivity to be guaranteed, the recommended number of clients
is 8.
DB9000-TX AND DB9000-RX SET-UP
Prior to implementing the below written adjustments, the following requirements should be
fullled:
• DB9000-TX must have a static IP address;
• If the device is placed behind a router, you will have to make sure that the Stream Server
Port is properly NAT forwarded;
• DB9000-RX may have a dynamic IP address;
• DB9000-RX should have access to DB9000-TX over the network (Internet or LAN).

65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: of[email protected] ,Web: www.devabroadcast.com
- 6 -
DB9000-TX STREAMING AUDIO SERVER SET-UP
1. Go to Conguration> IP Audio;
2. Choose the preferred audio signal input;
3. Assign Encoder + Sample rate and the desired Signal quality. The combination of these
parameters will dene the required minimum bandwidth of your network connection;
4. Then in Stream Settings section – specify the Port to be used and the Maximum supported
connections;
5. Preferably change the Name of the stream to identify you server easily;
6. Press [Save] to save the applied changes.
For detailed information and instructions on how communication with the DB9000-TX can be
established, please refer to “Appendix A - DB9000-TX Quick User Guide” on page 7.

65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: of[email protected] ,Web: www.devabroadcast.com
- 7 -
DB9000-RX IP AUDIO CLIENT SET-UP
1. Go to Conguration> IP Audio;
2. In IP Audio Client section – URL of the DB9000-TX Server should be specied. The
URL is a mandatory requisite needed in order for a connection with the server to be
established. The URL could be compound of DB9000-TX’s IP Address and Server Port, ex.
192.168.120:5000;
3. Choose the preferred decoder, prebuffer and specify buffer timeout. The decoder set in
the DB9000-RX must match the encoder specied in DB9000-TX;
4. If needed, set new gain adjustment settings;
5. From the Source priority Section set the priority of the IP Audio Client;
6. Press [Save] to save the applied changes;
7. Apply the same settings to all IP Audio clients to be used in the conguration.
For detailed information and instructions on how communication with the DB9000-RX can be
established, please refer to “Appendix B - DB9000-RX Quick User Guide” on page 11.

65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: of[email protected] ,Web: www.devabroadcast.com
- 7 -
Appendix A
DB9000-TX
Professional IP Audio Encoder
Quick User Guide
BEFORE YOU USE THIS PRODUCT
In order to be able to enjoy all the benefits of owning your new
DEVA product, please verify first that the latest software and
firmware release were installed.
Visit www.devabroadcast.com/downloads for the most
recent software and firmware downloads, prior the installation.

65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: of[email protected] ,Web: www.devabroadcast.com
- 8 -
This Quick user guide will make the installation of DB quick and easy these
principles, yo ca simplify the process and save yourself extra time and effort
9000-TX . Applying
u n . For more information
about the Safety precautions and the Operating environment recommendations please refer to the
User Manual.
The encoder has to be connected to the local network or Internet by cable with RJ-45 connector.
As only one input at a time can be managed by the encoder, please select the preferred signal source
input - either analog or digital one:
For use a cable that ends with two standard XLR jacks to connect the analog signal
source to the analog audio inputs of DB9000-TX.
For use a cable that ends with standard XLR jacks to connect the AES/EBU signal
source to the digital audio input of DB9000-TX.
Connect the device to theAC power.
F
Analog audio
Digital audio
OTEN : or the RS-232 COM PORT use a standard DB-9 cable to connect DB9000-TX to any RS-232
compatible equipment.
Open a WEB Browser and enter the device IP Address in the browser's address field, them press
Enter. The web interface will be displayed Current status information will be displayed comprising Audio
Status; Network Status; onnection Status
For further reference see the detailed explanation on the right part of the screen.
:
Active c s .
A sername and assword may be requested if the
Access Control i turned on and a page other th n
STATUS is selected. Default values are and .
u p
s a
user pass
DB9000-TX is controlled trough a build in WEB Server and a standard web browser can be used to
monitor its status or to make some adjustments.
To operate the device you need to know its IP Address. In case you are not aware of it, you can hear it
through the headphones when you turn on the the device. Alternatively, use the Network discovery feature
at Local networks ( ).for reference see tepS 8
WEB Interface
STEP 3
Configuration
STEP 2
Connection
STEP 1

65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: of[email protected] ,Web: www.devabroadcast.com
- 9 -
General Network ettingsS
If you plan to use static settings please disable the DHCP and fill in the
information requested - IP Address, Netmask, Gateway, Primary and
Secondary DNS. Otherwise, enable the DHCP.
SNMP Settings
Press the to download the latest available DB90
TX SNMP MIB file. Then Agent ID, Agent Port,
Communit , Manager IP and Manager Port.
is used to identify the device among others when a SNMP
notification is send. Agent - enables/disables SNMPAgent.
Download button
specify
Agent ID
00-
Red/Write
ies
Web erver ettingsS S
In order to enhance the security of DB9000-TX you can set new
Username and Password. In case a dialog box appear, fill in the NEW
username and password requested.
u p d fieldsNOTE: If sername and asswor are left blank, security is used.NO
NOTE: The MIB file may vary from one firmware revision to another.
Downloading this file from the device guarantees that you have the
latest MIB file.
Audio Settings
Choose the preferred audio signal source. Assign Encoder +Sample rate
and th signal quality. The combination of these parameters will
define the of your Internet connection.
PCM will quality but Network andwidth will be
required
e desired
required bandwidth
improve the , higher b
consequently.
NOTE:
RTPAudio Player
The RTP Settings require Server Address and Port to be
entered.
Decoders'
Icecast Receiver
Decoder IP filled in
The username and password are used to secure the connection. Make
sure to enter the same information on both sides of the connection.
Address and Port should be .
Stream Settings
Preferably c device
d the s
hange the name of the .
If you decide to use the Stream Server you should make adjustments to
the Port an maximum connection which will be supported.
Later on it will be used as a
title name on all WEB pages. Customizing the name will make DB9000-TX
more recognizable. Insert the TCP port in the Port field AFTERWARDS.
NOTE: For more information refer to the help section on the right part of the
screen, containing brief information about each of the fields. For field
description display, point the mouse cursor on the fields on the right.
NOTE: The selected encoder must match the settings of the decoders on
the other side of the connection.
Step 5. IP Audio Configuration
Step 6. COM Port Configuration
STEP 4
Network Configuration
STEP 5
IP Audio Configuration
Step 4. Network Configuration
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali DEVA Convertitore multimediale