Dialight WOSU22BG2 Manuale utente

9100-127-2989-99 REV B
1501 Route 34 South, Farmingdale, NJ 07727
Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com
1
This Manual covers both the Wide angle and the Narrow long range
occupancy sensor.
Dialight Part Numbers described here-in are:
WO U22BG2 Wide angle
WO U12BG2 Long Range
Wide optic version Long Range Version
Wireless Occupancy Sensor
Wireless Occupancy
Sensor
User Guide

9100-127-2989-99 REV B
1501 Route 34 South, Farmingdale, NJ 07727
Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com
2
Contents
Introduction ..................................................................................................................................................................................3
Wireless Occupancy Sensor Gen 2 Specifications ......................................................................................................................4
Unboxing......................................................................................................................................................................................5
Sensor Overview..........................................................................................................................................................................6
Battery Installation/Removal.........................................................................................................................................................7
Sensor Lights...............................................................................................................................................................................8
Commissioning...........................................................................................................................................................................10
Wide Angle Sensor Ceiling Mount..............................................................................................................................................11
How to Mount.............................................................................................................................................................................12
Long Range Sensor Wall Mount ................................................................................................................................................13
How to Mount.............................................................................................................................................................................14
Troubleshooting .........................................................................................................................................................................15
Troubleshooting Continued:.......................................................................................................................................................16
Troubleshooting Continued:.......................................................................................................................................................17

9100-127-2989-99 REV B
1501 Route 34 South, Farmingdale, NJ 07727
Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com
3
Welcome to the Dialight Wireless Occupancy Sensor user manual. This product allows you to customize your entire
lighting network using independent Occupancy Sensors throughout your acility by turning lights on when
occupancy has been detected.
This guide provides you with the in ormation you need to get started.
Introduction
Keep These Instructions
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
•Refer to operating temperature ratings of this
device before installing.
•DO NOT let the sensor touch hot surfaces.
•DO NOT mount near gas or electric heaters
•Equipment should be mounted in locations
and at heights where it will not be subjected
to tampering by unauthorized personnel.
•The use of accessory equipment not
recommended by the manufacturer may
cause unsafe conditions.
•DO NOT use this equipment for other than
intended use.
•DO take pictures of the installation, wiring
and mounting for future reference.
•Battery life will vary upon traffic area of the
install
•Contact your local Sales representative or
Dialight when necessary
SAVE THESE INSTRUCTIONS!!
•The installation and maintenance must be
carried out by authorized personnel.
•Repairs and Installation must only be
carried out by a qualified electrician.
•Only genuine or authorized Dialight
replacement parts must be used when
unforeseen repairs are required.
•Observe the national safety rules and
regulations during installation!
•Mounting in extreme heat locations should
be avoided. Failure to do so could void all
warranties!
•No alterations are allowed without the
written agreement from Dialight Corp.
Alterations other than written in this manual
will void all warranties.
•Batteries should be removed when the
sensor is not being used
•It is suggested that a maintenance schedule
be set up for battery replacement.
SAVE THESE INSTRUCTIONS!!

9100-127-2989-99 REV B
1501 Route 34 South, Farmingdale, NJ 07727
Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com
4
Wireless Occupancy Sensor
Gen 2
Specifications
Description Wide Angle and Narrow Long Range Wireless High Bay Occupancy
Sensors
Certification
UL916
,
CSA C22.2 NO.205
Power nput
2x “AA” Lithium Batteries 1.5V
Operating Temperature
Operating Temperature: -40°C to +60°C
Estimated Battery Life
Up to 10 years
Radio Frequency
2.4Ghz
Sensing Area Wide Angle 20’-30’ (minor – major motion range), 1250 sq t, 120°
Long Range 100’ (maximum range), 7600 sq t ( loor + distance
coverage), 10° coverage angle
Sensing Technology
Passive In rared
Dimensions
5”D
x 2.38”
H
Weight
~8
.8
oz
Material
Housing
:
Grey Polycarbonate
Lens
:
High density polyethylene
P Ratings
IP66
Green LED
Green LED
lashes
one time
when motion is detected
Indicates battery voltage above 2.7 Volts.
Green LED lashes twice every 5 seconds while searching or a network
connection.
Red LED
A single red
LED
3
lash indicates motion detected
and low battery voltage below 2.7 Volts.
Reset Button
R
eset
s
the processor
LED On/Off Switch
Located on bottom o sens
or board, it
will turn the LED indicators ON or
OFF.
Leave Button
Push and hold or 5 seconds to orce sensor to leave its gateway
Join Button
Push and hold or 5 seconds. Sensor will double blink while trying to join a
gateway, Sensor will stop blinking i it doesn’t join a gateway within 30
minutes.

9100-127-2989-99 REV B
1501 Route 34 South, Farmingdale, NJ 07727
Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com
5
Unboxing
Included in the box:
This Manual
Qty 1 – Wireless Occupancy Sensor
Qty 3 – #8 lywood Screws
Qty 3 – #8-32 Machine Screws
Qty 2 – Lithium “AA” Batteries
Qty 2 – Battery Clips
Take Note of the following information:
Dialight Catalog Number:
Date Code:
Install Date:

9100-127-2989-99 REV B
1501 Route 34 South, Farmingdale, NJ 07727
Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com
6
Sensor Overview
2.38”
5.0”
Front View
3 Mounting Holes
Mounting Plate with Twist Lock
Sensor Lens
LED Indicators
Sensor Housing

9100-127-2989-99 REV B
1501 Route 34 South, Farmingdale, NJ 07727
Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com
7
Battery Installation/Removal
Removing Battery Cover
To remove the sensor, twist sensor cover counterclockwise to unlock it from the back plate.
Once cover has been removed you’re now ready to add or remove the batteries.

9100-127-2989-99 REV B
1501 Route 34 South, Farmingdale, NJ 07727
Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com
8
Sensor Lights
Installing Batteries
1. Remove AA batteries from their packaging.
2. Install batteries in the battery holder on the sensor making sure to orient them
according to the +/- symbols on the holder. Install provided battery clips.
3. Lock sensor to the back plate. Installation is the opposite of removal.
4. The sensor is now on and ready to be discovered.
NOTE: There is no on/off switch in the sensor. To power off the sensor, remove the batteries
from unit.
To turn on the ED Indicators
1. Twist open the sensor from the mounting plate.
2. Move the LED switch to the right to turn on the LED indicators.
NOTE: Turning switch to on will cause increase current draw to the batteries and will
shorten life based on the amount of motion detection.
3. Twist close the sensor back on to the mounting plate.
Battery Holder (BAT 1)
Battery Holder (BAT2)
LED On/Off Switch

9100-127-2989-99 REV B
1501 Route 34 South, Farmingdale, NJ 07727
Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com
9
Sensor Notifications: NOTE there are only 1 led of each color. Below is for clarity
One green blinking LED1 Motion means motion has been
detected and indicates a battery voltage of more than
2.7V.
Green LED1 Motion blinking twice in a second means sensor
is looking for a network to join and battery voltage is more
than 2.7V. Sensor will double green blink while looking for a
network for 30 minutes and then stop. ress the join button
for 5 seconds to start a new 30 minute search.
A single red LED3 Low Bat flash indicates motion detected
and low battery voltage below 2.7 Volts. Battery needs to be
replaced.
Only replace batteries with same size and type.
____________________________________________________________________________________
Red LED3 Low Bat blinking twice in a second means sensor
is looking for a network and battery voltage is under 2.7V.

9100-127-2989-99 REV B
1501 Route 34 South, Farmingdale, NJ 07727
Tel: (732) 919-3119 Fax: (732) 751-5778 www.dialight.com
10
Commissioning
NOTE: In order to confirm proper location it is advised to mount the sensor before discovering
it.
Adding Sensor to Gateway
1. When the green LED blinks twice a second on the sensor, the sensor is ready to be
discovered/commissioned.
2. Use a Dialight gateway to discover the sensor. ( lease refer to the gateway owner’s
manual for further instructions under the devices page.)
3. Once the sensor has been added to the gateway, the green LED will stop blinking at
the rate of twice a second. You have now connected the sensor to the gateway.
4. The green LED will then blink when motion is detected.
NOTE: There is a 90 second ideal mode after a trigger detection. Thus quick repeating
will not trigger additional events.
See the Gateway manual for setting up the sensor
Removing the Sensor from a Gateway
Due to failure or relocation
1. Go to the sensor and open it and hold the SW3 Leave button for 5 seconds
2. Sensor LED’s should now be double blinking
3. Check the gateway’s GUI to verify sensor was removed from device list. ( lease refer to
your gateway owner’s manual for further instructions.)
4. Your sensor is now ready to be added to another gateway.
SW3 LEAVE
SW1 RESET
SW2 JOIN
Questo manuale è adatto per i seguenti modelli
1
Indice