Dickey-John HydraDrive Manuale utente

INSTALLATION INSTRUCTIONS
HydraDrive
11001-1452-201702 Rev B
/I
Safety Notices ..................................................................................................... 1
HydraDrive ........................................................................................................... 3
Specifications .................................................................................................................... 3
General ............................................................................................................................................ 3
Electrical ........................................................................................................................................... 3
Hydraulic Connections ..................................................................................................................... 3
Components ......................................................................................................................4
Assembly .......................................................................................................................... 4
Implement Installation ........................................................................................ 7
Hydraulic Connections ....................................................................................... 9
Closed-Center Hydraulics ................................................................................................. 9
Connecting Multiple HydraDrives (Closed-Center Hydraulics) ........................................................ 9
Open-Center Hydraulics ................................................................................................. 11
Pre-check ........................................................................................................................ 13
Manual Override ............................................................................................................................. 13
Warranty ..............................................................................................................15

INSTALLATION INSTRUCTIONS
HydraDrive
11001-1452-201702 Rev B
II /

INSTALLATION INSTRUCTIONS
HydraDrive
11001-1452-201702 Rev B
SAFETY NOTICES / 1
SAFETY NOTICES
Safety notices are one of the primary ways to call attention to potential
hazards.
This Safety Alert Symbol identifies important safety messages in this
manual. When you see this symbol, carefully read the message that
follows. Be alert to the possibility of personal injury or death.
Use of the word WARNING indicates a potentially hazardous
situation which, if not avoided, could result in death or serious
injury.
Use of the word CAUTION with the Safety Alert Symbol indicates a
potentially hazardous situation which, if not avoided, may result in
minor or moderate injury.
Use of the word CAUTION without the safety alert symbol
indicates a potentially hazardous situation which, if not avoided,
may result in equipment damage.

INSTALLATION INSTRUCTIONS
HydraDrive
11001-1452-201702 Rev B
2 / SAFETY NOTICES

INSTALLATION INSTRUCTIONS
HydraDrive
11001-1452-201702 Rev B
HYDRADRIVE / 3
HYDRADRIVE
The HydraDrive is a hydraulic motor with an integrated flow control valve
that delivers high torque at low speeds while consuming minimal hydraulic
oil. Hydraulic ports on the drives allow multiple HydraDrives to be
connected.
SPECIFICATIONS
GENERAL
RPM Operating Range: 4 to 180 RPM
Hydraulic Oil Usage: 4.9 in 3/rev (80 cc/rev)
Max Hydraulic Oil Usage: 4 gpm (15 LPM)
Maximum Torque: 1400 inch pounds (160 Nm)
Dimensions: 10.2 x 5.0 x 6.3 in (260 x 127 x160 mm)
Weight: 19.8 lbs (9.0 Kg)
ELECTRICAL
Control Signal: 12 Volts pulse width modulated
Control Frequency: 200 Hz
Maximum Current: 1.5 Amps
HYDRAULIC CONNECTIONS
Tractor Hydraulics: Closed Center or Open Center
HydraDrive Hydraulics:
Pressure port 1/2” SAE (7/8 UNO)
Return port 1/2” SAE (7/8 UNO)

INSTALLATION INSTRUCTIONS
HydraDrive
11001-1452-201702 Rev B
4 / HYDRADRIVE
COMPONENTS
HydraDrive components consist of the following items that must be
assembled prior to installation.
• Hydraulic motor
• Valve manifold
• Valve cartridge
•(4)bolts
A bracket will be required to attach the HydraDrive to the implement.
Figure 1
HydraDrive Components
ASSEMBLY
The mounting position of the manifold onto the motor will affect:
• Direction the motor will turn (clockwise or counterclockwise). The
motor direction is identified on the type and bottom of the manifold.
• Pressure and return inlets
To Assemble the HydraDrive:
1. Remove the red blocking plugs from the hydraulic motor and verify
o-rings are fitted within the pressure and return inlets.
IMPORTANT: Ensure the hydraulic motor mounting surface is clean
with no dust particles before attaching to the manifold.
Hydraulic Motor
Valve Manifold
Valve Cartridge
4 Bolts

INSTALLATION INSTRUCTIONS
HydraDrive
11001-1452-201702 Rev B
HYDRADRIVE / 5
Figure 2
Verify O-rings
Mounting of the manifold determines which direction the motor
will turn. Motor direction is identified on the top and bottom of the
manifold.
Figure 3
Secure Manifold to Motor
2. Determine the appropriate motor direction and align the valve manifold
mounting holes to the hydraulic motor.
3. Insert bolts into manifold holes and use an Allen wrench to tighten and
secure to motor.
Remove plugs and
verify o-rings are in place
Remove plugs and
verify o-rings are in place
Align valve
to motor.
Insert bolts to
secure placement.

INSTALLATION INSTRUCTIONS
HydraDrive
11001-1452-201702 Rev B
6 / HYDRADRIVE
4. Place the valve cartridge into the side hole of the valve manifold and
screw in until secure.
Figure 4
Valve Cartridge Placement
The motor is now ready to install to implement.
Figure 5
Assembled HydraDrive

INSTALLATION INSTRUCTIONS
HydraDrive
11001-1452-201702 Rev B
IMPLEMENT INSTALLATION / 7
IMPLEMENT INSTALLATION
To attach the HydraDrive to the implement, a heavy-duty bracket is required
either by making or purchasing from a dealer or distributor. The typical
mounting location is the center of the implement above the final planter
drive.
To Install HydraDrive to the Implement:
1. Attach steel bracket to implement frame to accommodate mounting of
HydraDrive.
2. Mount the HydraDrive to the bracket.
3. Attach appropriate drive sprocket on the 1” keyed output shaft of the
HydraDrive.
4. Install application rate sensor and coupler onto the 1” output shaft of
the HydraDrive.
Figure 6
Bracket Mounted to Implement
Drive
Sprocket
Application
Rate Sensor
Coupler
Bracket Mounting
Holes

INSTALLATION INSTRUCTIONS