Diehl Metering IZAR RDC Manuale utente

IZAR RDC BATTERY
User guide

IZAR RDC Battery
2 08/2019
Table of contents
1Product description ................................................................................................................3
1.1 Brief description.................................................................................................................3
1.2 Product overview...............................................................................................................3
1.3 Package contents...............................................................................................................4
2Product characteristics ...........................................................................................................5
2.1 Technical data...................................................................................................................5
2.2 Dimensions .......................................................................................................................5
3Concentrator Installation ........................................................................................................6
3.1 Usage precautions .............................................................................................................6
3.2 SIM card installation ..........................................................................................................6
3.3 Connecting the battery pack...............................................................................................7
3.4 Cover installation...............................................................................................................7
3.5 Connecting the inputs/outputs............................................................................................8
3.6 Connecting the external power supply (optional) .................................................................9
3.7 “Data logger radio” mode (optional)....................................................................................9
3.8 Wall mounting and screw fixing ........................................................................................ 10
4Configuration / starting up.................................................................................................... 10
5Identification ....................................................................................................................... 10
6Maintenance........................................................................................................................ 11
6.1 Battery pack replacement................................................................................................. 11
7Troubleshooting................................................................................................................... 12
7.1 LED information............................................................................................................... 12
7.2 Diagnosis ........................................................................................................................ 12
8Regulations ......................................................................................................................... 13
9Open source software notice ................................................................................................ 13

IZAR RDC Battery
3 08/2019
1PRODUCT DESCRIPTION
1.1 BRIEF DESCRIPTION
IZAR RDC BATTERY is a battery-driven stand-alone concentrator enabling:
•Implementation of a “remote reading” solution in autonomous mode i.e. without 230 V
connection.
•Study of consumption profiles on one or more meters, thanks to its « Data logger radio » functions.
•Monitoring of main and sector meters requiring a stand-alone concentrator.
•Complementarity with an « IZAR R4 » long-range network solution to cover isolated areas and
difficult to reach meters.
IZAR RDC BATTERY allows to read out smart radio metering with cyclic interval or time point fully
configurable. Meter information is stored and send to a FTP/SFTP server.
One data emission sequence is defined with different operations:
•Check of the date/time of the system (Server NTP)
•Data File transfer (FTP/SFTP)
•Control of new « firmware »
•Control of new « settings »
1.2 PRODUCT OVERVIEW

IZAR RDC Battery
4 08/2019
1.3 PACKAGE CONTENTS
IZAR RDC BATTERY is delivered in individual packaging and comprises the following elements:
Housing with electronic card
+
Battery pack and connector
Cover
Protective cover for antenna connectors
Torx key
Cover fixing screws
Retaining screws of the case’s cover
Screws and dowels for wall mounting
Optional external power connector
Installation guide

IZAR RDC Battery
5 08/2019
2PRODUCT CHARACTERISTICS
2.1 TECHNICAL DATA
Technical data
Frequency
868.95 MHz (T1/C1 mode) or
434.475 MHz (T1 mode only)
Communication protocols
wM-Bus (EN13757-3/-4) / PRIOS / OMS
Conditions of use
Operating temperatures
-20 ... +70 °C
Storage temperatures
-20 … +70 °C
Protection class
IP 65 (only when vertically installed against a wall in
order to protect the slotted holes)
Ambient humidity
10% to 90% (non-condensing)
Communication
GSM / GPRS
1 internal antenna + 1 SMA external connector
ISM (wM-Bus)
1 internal antenna + 2 SMA external connectors
Consumption
Power supply
Lithium battery pack or external connector
Typical power
5 VA
Nominal voltage
12 … 24 V DC
Permissible voltage
6 … 36 V DC
Battery pack autonomy
Up to 10 years*
*Depending on the setting and in standard conditions of use and temperatures. Theoretical lifetime,
not guaranteed.
2.2 DIMENSIONS
Dimensions
Length
220 mm
Width
220 mm
Height
51.80 mm

IZAR RDC Battery
6 08/2019
3CONCENTRATOR INSTALLATION
3.1 USAGE PRECAUTIONS
IZAR RDC BATTERY must be installed and put into operation by qualified staff. This
also applies to maintenance work during the life of the product.
Failure to follow these instructions can lead to serious health hazards or the risk of
electrocution.
Electronic discharge! Strict compliance with the pertinent provisions regarding ESD
(ElectroStatic Discharge) must be observed.
Electronic product must be handled with caution!
Battery pack must be handled with care! Do not disassemble!
Do not short-circuit!
Housing gasket for IP65
The housing must be open and close with specific care to avoid any displacement of
the gasket.
If after this operation the gasket in not well in place or twisted, the IP65 rating of the
device is not valid anymore.
IZAR RDC BATTERY is designed for wall mounting installation. When installing,
ensure that the housing is mounted in compliance with IP 65 protection class and
without any mechanical stress.
IZAR RDC BATTERY must be installed vertically against a wall, antenna connectors
facing downwards in order to protect the oblong holes and remain IP 65.
If the product is defective, stop using it and contact the after-sales service.
Damage to the housing as well as the presence of significant humidity in the
housing are considered as defects.
3.2 SIM CARD INSTALLATION
The SIM card is not provided. Check with your telephone company that is operational.
The card format must be: Standard format “Mini SIM (25x15 mm)
The concentrator functions independently of the type of local operator used. It is also possible to use
multi-operator SIM card.
The SIM card installation must be performed with power supply off.
Always disconnect the battery pack before any intervention!
Insert the SIM card in the compartment as shown below and lock it.

IZAR RDC Battery
7 08/2019
Before closing the concentrator, make sure that the SIM card is properly locked
in its compartment.
3.3 CONNECTING THE BATTERY PACK
The battery pack is supplied unconnected to avoid unnecessary discharge during delivery of the
equipment. It should therefore be connected - as explained on the picture below. The connector is
equipped with a fool-proof notch that prevents manipulation errors.
Caution: In case of difficulty of insertion of the connector, do not force but double check its
direction.
The battery has a lifespan of up to 10 years depending on the setting. The battery pack is
replaceable on site (refer to chapter “battery pack replacement”).
Only use the Diehl Metering referenced battery pack!
3.4 COVER INSTALLATION
Close and screw the cover on the box once the SIM card (and in option the SD card) securely locked
in place and the battery pack is connected.

IZAR RDC Battery
8 08/2019
3.5 CONNECTING THE INPUTS/OUTPUTS
Connectors
Type
Functions
RF1
SMA
Antenna #1 IZAR radio reception
RF 2
SMA
Antenna #2 IZAR radio reception
SUPPLY 12/24V
External power supply 6…36V DC
GPS
SMA
Not used
GSM SMA
Transmitting antenna via the mobile phone
network

IZAR RDC Battery
9 08/2019
3.6 CONNECTING THE EXTERNAL POWER SUPPLY (OPTIONAL)
IZAR RDC BATTERY can also be powered by a DC voltage source (solar for example…).
Specifications: 5 VA / 6 … 36 V DC
Do not exceed the permissible voltage (36 V DC)!
3.7 “DATA LOGGER RADIO” MODE (OPTIONAL)
IZAR RDC BATTERY can also be used in “Data logger radio” mode. This mode makes it possible to
read one or more meters with a very fine time step to analyse consumption profile data for instance,
or leak detection.
In this case, the concentrator is configured in a specific mode and stores all the data on a SD
memory card (optional). It shall not be configured with a GPRS/3G connection.
The user must guaranty that the SD card is not full by retrieving the data and erasing it from the SD
card regularly.
Compatible SD cards with following characteristics:
•FAT 32 formatting; only one partition
•Micro SD card up to 16 Go
•Micro SD HC card up to 32 Go (no specific speed class)

IZAR RDC Battery
10 08/2019
3.8 WALL MOUNTING AND SCREW FIXING
A drilling template is provided with the installation guide to facilitate positioning and installation on
the wall.
4CONFIGURATION / STARTING UP
IZAR RDC BATTERY must be programmed on-site via a Bluetooth or Bluetooth Low Energy interface
using the IZAR@RDCBV Config software.
Please refer to the IZAR@RDCBV Config software user guide.
5IDENTIFICATION
Data matrix contents:
Indice
Altri manuali Diehl Metering Accessori per fotocamere