Digicom LEONARDO56 Manuale utente

Cod 7D1062 rev. 2.0 del 03/99
LEONARDO56
External RS232
External USB
Internal ISA Card
PC Card
http://www.digicom.it
User's Manual
User's Manual

LEONARDO 56
Index
I
INDEX
PREFACE III
1. GENERALITY 1.1
1.1. PRODUCT PACKAGE CONTENTS 1.2
1.2. PRODUCT FEATURES 1.2
2. INSTALLATION 2.1
2.1. HARDWARE INSTALLATION 2.1
2.1.1. LEONARDO 56 EXTERNAL RS232 2.1
2.1.2. LEONARDO 56 EXTERNAL USB 2.2
2.1.3. LEONARDO 56 INTERNAL ISA BUS 2.3
2.1.4. LEONARDO 56 PC CARD-PCMCIA 2.3
2.2. SOFTWARE INSTALLATION 2.4
2.2.1. WINDOWS® 95/98/NT4.0 EXTERNAL OR INTERNAL VERSION 2.5
2.2.2. WINDOWS® 95/98/NT4.0 EXTERNAL USB VERSION 2.7
2.2.3. WINDOWS® 95/98/NT4.0 PC VERSION 2.10
2.2.4.
MACINTOSH® - MODEM INSTALLATION FOR ARAOPEN TRANSPORT
2.11
3. MODEM AT COMMAND SET 3.1
3.1. AT COMMAND SET DESCRIPTION 3.1
3.1.1. MNP10 COMMAND 3.11
3.1.2. CELLULAR MODE COMMAND 3.11
3.2. S REGISTERS 3.11
3.2.1. SPECIAL S REGISTER DESCRIPTION 3.12
3.3. CONNECTION MESSAGE 3.13
4. DIAGNOSTIC 4.1
4.1. LOCALANALOG LOOPBACK TEST (CCITT LOOP 3) 4.1
4.2. LOCAL DIGITAL LOOPBACK TEST (CCITT LOOP 2 LOCAL) 4.1
4.3. LOCALANALOG LOOPBACK WITH SELFTEST 4.1
4.4. REMOTE DIGITAL LOPBACK 4.2
4.5. REMOTE DIGITAL LOOPBACK WITH SELFTEST 4.2
DECLARATION OF CONFORMITY V

LEONARDO 56
Preface
III
PREFACE
All rights reserved; no part of this publication may be reproduced, stored in a retrieval
system, or trasmitted in any form or by any means, electronic, otherwise, without the prior
written permission of DIgicom S.p.A..
The contents of this booklet may be modified without prior permission.
Every possible care has been taken in testing and putting together all the documentation
containedinthisbooklet,howeverDigicomcannottakeanyresponsabilitybroughtbythe
use of this booklet.
The following installation rules should be respected in order to have the best working
order of the equipment and for the user’s safety.
ENVIROMENTAL CONDITIONS
For all devices:
ENVIROMENTAL TEMPERATURE RELATIVE HUMIDITY
from 0 to + 45°C from 20 to 80% n.c.
Rapid changes of temperature or humidity should be avoided (0,03°C/min).
This equipment, including cables, should be installed in an area free from:
lDust, humidity, heat from direct sun light.
lObjects which irradiate heat. These could cause damage to the container or other
problems.
lObjects which produce a strong electtromagnetic field (loudspeakers, etc.)
lLiquids or chemical corrosive substances.
GENERAL WARNINGS
For all equipment powered directly from mains power
POWER SUPPLY 220-240 Volt single phase 50 Hz
ISOLATION CLASSIFICATIONS only those indicated on the equipment label
NOMINAL CURRENTS only those indicated on the equipment label
To avoid electric shock, the equipment should never be opened.Ask qualified personnel
help.
Disconnect the power cable from the wall outlet when the equipment is not to be used for
a long period. To disconnect the cable pull it by the plug, never pull it by the cable itself.
If there should be liquid or object penetration in the equipment, disconnect the power
cable and call a qualified personl for testing.
CLEANING THE TERMINAL
Use a clean and soft cloth. Wet the cloth with water or natural detergent if it is necessary
to remove any stains. Never use chemical products such as petrol or solvents.
VIBRATIONS OR DROPPING
Caution against vibrations and dropping
WARNING
This is a class A product.
In a domestic environment this product may cause radio interference
in which case the user may be required to take adequate measures.

Generality
1.1
1. GENERALITY
This operating manual describes the installation procedures and the main
featuresof the Leonardo56 modem family. Leonardo 56 isthe perfect modem
fax sulution for applications that require ultra high speed and reliability over a
remote user analog line: the ideal solution for data, and fax, communication
for professional, office or the home user.
This operating manual is for the following modem: Leonardo 56 external
RS232 & USB (PC or Macintosh), Leonardo 56 internal ISA card (PC) and
Leonardo PC Card (PC and Macintosh). See the details of the installation
procedure of your enviromental in the installation chapter.
DEAR CUSTOMER,
Your Leonardo 56 complies with the 56Kbps standard
accordingto the ITU-TV.90regulationfor data communication
up to 56000 bps.
The V.90 standard, like the K56Flex, has an unbalanced
connectionspeed.It means thatyou have aconnectionwhere
data are received at the maximum speed of 56000 bps and sent at the
maximum speed of 33.600 bps.
The unbalance, due to the technical limitations of the analog telephone lines,
allows to carry out connections with top performances in applications of
Internet access or remote access.
In order to reach the connection speed of 56000 bps, according to the 56K
technology, one of the two modems must be connected to a digital network
(usually ISDN or *64 in G703/G7047). In fact, the modems of the Services
Provider (Internet POP or access servers) are special ones, like "Central
Site Modem"(CSM).
Themaximum speed,when receiving data, in users connections over analog
line is 33.600 bps.
ADDITIONAL AT COMMAND FOR 56K
Your Leonardo 56 has been tested with the most popular Communication
softwarerunning on PC or Macintoshplatforms: thecorrect initialisationstring
to enable 56K speed is:AT+MS=12,1,300,56000,1,0

1.2
LEONARDO 56
Generality
1.1. PRODUCT PACKAGE CONTENTS
l1 User manual
l1 Digicom modem: Desktop (external) or ISA card (internal) or PC card
(PCMCIA)
l1 Cable to connect the modem to the telephone line
l1 Cable to connect the modem to your PC or Macintosh (for the external
version only)
l1 Floppy diskette or CD ROM containing Modem Drivers
l1 Package of Data/fax communication software
1.2. PRODUCT FEATURES
lComputer speed: up to 115.200 bit/s
lDatamodem modes for: V.90, K56flex™,V.34, V.32bis, V.32,V.22bis, V.22,
V.21, V.23 (1200/75).
lFax modem modes: 9600/4800bps, V.29/V.27 Group 3 and 14.400bps
V.17.
lEnchanced AT commands set with autobaud for the data mode up to
115.200 bit/s.
lClass 1 fax command set
lNon volatile memory directory for user profiles
lAuto dial and autoanswer
lTone and pulse dialing
lError Correction: MNP 4/10 and V.42
lData Compression: MNP 5 and V.42bis

LEONARDO 56
Installation
2.1
2. INSTALLATION
2.1. HARDWARE INSTALLATION
2.1.1. LEONARDO 56 EXTERNAL RS232
See the following picture
to connect your modem to the
COM port of your PC and the
telephone cable to the telephone line.
See the following picture to connect your modem to the GEO port of your
Macintosh® and the telephone cable to the
telephone line.
After the cable installation, connect theAC adapter
to the main power supply
outlet and switch ON the
power switch on the rear
panel. Check that the
green LED PWR indicator
light is on.
For the next step see the section Software Installation.

2.2
LEONARDO 56
Installation
2.1.2. LEONARDO 56 EXTERNAL USB
See the following pictures to
connect your modem to the
USB port of your Computer
and the telephone cable to
the telephone socket of the
modem.
After the cable installation
switch on your Computer and
check that the green LED PWR
indicator light is on.
For the next step, see the
section Software Installation.

LEONARDO 56
Installation
2.3
2.1.3. LEONARDO 56 INTERNAL ISA BUS
Caution: Before removing the cover of
any computer, turn-off and unplug
the mains power cord.
Remove the computer’s cover
according to the computer
manual.
Select any available ISA bus
slot.
The internal modem can work
in an 8 or 16 bit slot. Remove
the slot cover and save the
screw.
Carefullyinsertthe modem into
the selected slot.
Secure the bracket with the
screw saved earlier.
Replace the computer cover and plug in your computer.
Connect the telephone cable to the telephone line.
For the next step see the section Software Installation.
2.1.4. LEONARDO 56 PC CARD-PCMCIA
The Leonardo 56 PC Card is
compliant with any PCMCIA 2.0
socket.
Insert the card in the PCMCIA slot
of your computer the correct way
up.
The way up sign is on the modem
sticker.
Connect the telephone cable to the
telephone line.
For the next step see the section
Software Installation.

2.4
LEONARDO 56
Installation
2.2. SOFTWARE INSTALLATION
lWINDOWS® 95/98/NT4.0 DRIVER
Before starting with the software installation, please read the file Readme.txt
presenton the FloppyDisk or theCD ROM includedwith the modempackage.
Inthisfile you canreadmore details aboutthedriver installation forthedifferent
versions of Windows® 95/98 and also the latest release notes or driver
upgrades not available at the time of printing this manual.
lMACINTOSH® Driver ARA/Open Transport
Make a copy of the Leonardo driver file from the Floppy Disk or the CD ROM
to your hard disk in the folder Modem Script (System Folder- Extension-
Modem Script).
Your Leonardo driver is present in the modem list and available for any
application that uses ARA/Open Transport.
Remember to select the correct communication port in the application in
accordance with the hardware installation.
lOTHER DRIVERS
For other Operating Systems, see the installation procedures on the Floppy
Disk or the CD ROM included with the modem package.

LEONARDO 56
Installation
2.5
2.2.1. WINDOWS® 95/98/NT4.0 EXTERNAL OR INTERNAL VERSION
1. Run Windows®95/98/NT4.0
2. Select from the START icon : Settings-Control Pannel- Modem- Add
3. From the window Install New Modem put a tick in the box “Don’t detect my modem: I will
select it from a list” and select the button: Next.
4. From the new window Install New Modem click the button Disk
Questo manuale è adatto per i seguenti modelli
1
Indice
Manuali Hardware per computer popolari di altre marche

EMC2
EMC2 VNX Series Manuale del proprietario

Panasonic
Panasonic DV0PM20105 Manuale utente

Mitsubishi Electric
Mitsubishi Electric Q81BD-J61BT11 Manuale utente

Gigabyte
Gigabyte B660M DS3H AX DDR4 Manuale utente

Raidon
Raidon iT2300 Manuale utente

National Instruments
National Instruments PXI-8186 Manuale utente











