10 www.dimplex.com
Installation
If the desired location is susceptible
to signicant air movement, i.e.
air vents, the dierent installation
options illustrated in Figure 3 can
be used. It is important that the
surface surrounding the top of the
cassette have at least a 3 in
(72 mm) clearance from any vertical
surface and the barrier be 10 in
(254 mm) high from the installation
surface, to ensure optimal ame
production.
!NOTE: It is recommended
that during drywall installation
and nishing the media plate be
installed with the provided bag
to prevent dust and debris from
entering the unit.
1. Use studs to frame an
enclosure with the following
minimum internal/opening
dimensions. Note that the
Media Plate (supplied) and Log
Set (optional) require dierent
opening widths - see Figure 2.
!NOTE: A fresh air inlet that
is a minimum of 80in2 (516 cm2)
for the CDFI1000-PRO and 40in2
(258 cm2) for the CDFI500-PRO, is
required. The air intake must allow
for air to reach the underside of the
Opti-myst Cassette (Figure 2 & 3).
If installing into the Opti-myst Pro
Box Heater (optional), no additional
air intake is required. The Opti-
myst Pro Box Heater is designed
with air intakes included.
For optimal performance, a
clearance of 18 in (457 mm)
between the installation surface
and any surface above should be
maintained. A minimum clearance
of 16 in (405 mm) must be
maintained.
2. In the back left corner of
the unit, locate and remove
the electrical cover plate, by
removing the two securing
screws.
3. Install a ⅜ in (10 mm) or ½ in
(13 mm) cable connector, not
included, suitable for mounting
in a ⅞ in (22 mm) hole, to the
cable plate and feed the supply
cable through the connector.
The cable plate can be
removed by removing the two
securing screws on either side,
to allow for easier access.
CAUTION: Use two conductor,
non-metallic sheath cable with
Cable Plate
Electrical Cover Plate
Holes for
securing to
framing
Cord Outlet
for Tethered
Controller
Figure 4